Skip to content

Case Report

Frontiers in Cardiovascular Medicine ·

Volume 13 - 2026 | https://doi.org/10.3389/fcvm.2026.1961251

Case Report: Endovascular repair for true lumen collapse after frozen elephant trunk for type A aortic dissection

  • Xiaoping Fan1
  • Kunyang He1
  • Wenliu Xu1
  • Zengxiao Zou1
  • Naijimuding Abudurexiti1
  • Ge Wang1*corresponding author
  • Chaojie Wang1*corresponding author
  1. Department of Cardiovascular Surgery, Guangdong Provincial Hospital of Chinese Medicine, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China
Article metrics0 viewsView details

Abstract

Frozen elephant trunk (FET) was applied in the treatment of type A aortic dissection, enabling one-stage repair of the aortic arch and proximal descending aorta while promoting true lumen expansion. However, inadvertent FET deployment into the false lumen is a rare but catastrophic complication that may cause true lumen collapse and life-threatening visceral malperfusion, with limited reports on its endovascular management. Here, we present the case of a 44-year-old female who underwent Bentall procedure, total arch replacement, and FET implantation for acute type A aortic dissection at a local hospital. Postoperatively, she developed visceral malperfusion manifesting as abdominal distension, hepatic and renal dysfunction, and elevated lactate levels. Computed tomography angiography revealed that the FET stent had been inadvertently deployed into the false lumen, resulting in true lumen collapse. Emergency thoracic endovascular aortic repair was performed, establishing a “FET-false lumen-true lumen” pathway with an additional stent graft to redirect aortic flow into the true lumen. Computational fluid dynamics analysis showed that the postoperative hemodynamics have been significantly improved. The patient's organ function normalized, and she was discharged two weeks later, remaining asymptomatic at 8-month follow-up. Endovascular reintervention with additional stent grafting to establish a flow-redirection pathway is a feasible and effective strategy for true lumen collapse following inadvertent FET deployment into the false lumen. Prompt recognition, timely imaging confirmation, and immediate intervention are paramount to mitigating the risks associated with this serious complication.

Keywords

Introduction

Frozen elephant trunk (FET) was applied in the treatment of type A aortic dissection, enabling one-stage repair of the aortic arch and proximal descending aorta while facilitating true lumen expansion and false lumen thrombosis (1, 2). However, inadvertent FET deployment into the false lumen is a rare but catastrophic complication that may cause true lumen collapse and life-threatening malperfusion of visceral organs, spinal cord, or lower extremities (3, 4). Prompt recognition and urgent reintervention are therefore critical. Endovascular salvage strategies, including flap fenestration and additional stent grafting to redirect flow into the true lumen, have shown efficacy, yet reported experiences are limited.

Herein, we report a case of true lumen collapse after inadvertent FET deployment into the false lumen, managed with endovascular reintervention and evaluated by CFD analysis of pre- and post-procedural hemodynamics. The Guangdong Provincial Hospital of Chinese Medicine Ethics Committee approved this retrospective review (ZE2022-303-01; approved October 11, 2022) and the patient provided informed written consent for the publication of the data.

Case report

A 44-year-old female underwent Bentall procedure, total arch replacement combined with FET (Cronus®, Microport Medical Corp., Shanghai, China) implantation for acute type A aortic dissection at a local hospital. Postoperatively, she developed abdominal distension, impaired liver and renal function along with elevated lactate levels, which failed to improve with medical management. Computed tomography angiography (CTA) was subsequently arranged, revealing that the FET stent had been inadvertently deployed into the false lumen, resulting in collapse of the true lumen (Figure 1). As the visceral branches, including the celiac artery, superior mesenteric artery, and both renal arteries, originated from the compressed true lumen, visceral malperfusion ensued.

Computed tomography angiography before intervention. **(A)** Three-dimensional reconstruction of the revealed that the FET was inadvertently deployed into the false lumen resulting in true lumen collapse. **(B–F)** Computed tomography demonstrated true lumen collapse, with the visceral branches originating from the compressed true lumen, leading to visceral malperfusion. TL, true lumen (red arrow); FL, false lumen; FET, frozen elephant trunk.
Figure 1. Computed tomography angiography before intervention. (A) Three-dimensional reconstruction of the revealed that the FET was inadvertently deployed into the false lumen resulting in true lumen collapse. (B–F) Computed tomography demonstrated true lumen collapse, with the visceral branches originating from the compressed true lumen, leading to visceral malperfusion. TL, true lumen (red arrow); FL, false lumen; FET, frozen elephant trunk.

Computational fluid dynamics (CFD) was utilized to analyze the hemodynamics of aortic dissection with true lumen collapse. (Figure 2). The results indicate that the pressure within the false lumen of the descending aorta at the end of systole is relatively high, whereas the pressures in the true lumen and the visceral branch vessels are comparatively low. The wall shear stress of the true lumen is relatively diminished. Blood flow velocity is higher in the false lumen, while it is lower in the true lumen and the visceral branch vessels. Throughout the entire cardiac cycle, the flow rates in the true lumen and the visceral branches remain low, in contrast to the higher flow rate observed in the false lumen.

Computational fluid dynamics. At the end-systole, pressure in the acceding aorta and the false lumen of the descending aorta decreased significantly after TEVAR. Wall shear stress increased in the true lumen and decreased in the false lumen. Blood flow velocity increased significantly in the true lumen and the branch vessels, while decreased in the false lumen.
Figure 2. Computational fluid dynamics. At the end-systole, pressure in the acceding aorta and the false lumen of the descending aorta decreased significantly after TEVAR. Wall shear stress increased in the true lumen and decreased in the false lumen. Blood flow velocity increased significantly in the true lumen and the branch vessels, while decreased in the false lumen.

After being transferred to our hospital, emergency thoracic endovascular aortic repair (TEVAR) was performed (Figure 3 and Supplementary Video S1). Initially, angiography of the descending aortic false lumen was conducted (Supplementary Video S2), showing direct blood flow from the FET stent into the false lumen and delayed opacification of the visceral branches. This was followed by true lumen angiography (Supplementary Video S3), which demonstrated a narrowed true lumen without proximal communication to the false lumen; the visceral branches arose from this compressed segment. Through the compressed true lumen, the intimal tear close to the FET stent was superselectively cannulated to access the false lumen. Then, a guidewire was advanced retrograde into the FET stent, establishing a “FET-false lumen-true lumen” pathway. A subsequent thoracic endovascular stent (GORE TAG Thoracic Endoprosthesis, W.L. Gore & Associates, Inc., Arizona, USA) was deployed to redirect aortic flow into the true lumen, thereby restoring perfusion to the visceral branches. The aortic angiography confirmed flow through the FET and the newly placed stent into the true lumen, with earlier and improved opacification of the visceral branches compared to the preoperative state (Supplementary Video S4).

Intraoperative procedures. **(A)** Angiography of the descending aortic showed direct blood flow from the FET stent into the false lumen. **(B)** True lumen angiography demonstrated a narrowed true lumen and the visceral branches arose from this compressed segment. **(C)** Small intimal tears were identified distal to the stent graft. **(D)** Through the compressed true lumen, the tear close to the FET was superselectively cannulated to access the false lumen. **(E)** A guidewire was then advanced retrograde into the FET stent, establishing a “FET-false lumen-true lumen” pathway. **(F)** A thoracic endovascular stent was deployed to redirect aortic flow into the true lumen. **(G)** The aortic angiography confirmed flow through the FET stent and the newly placed stent into the true lumen. **(H)** The aortic angiography confirmed that the visceral branches were well perfused.
Figure 3. Intraoperative procedures. (A) Angiography of the descending aortic showed direct blood flow from the FET stent into the false lumen. (B) True lumen angiography demonstrated a narrowed true lumen and the visceral branches arose from this compressed segment. (C) Small intimal tears were identified distal to the stent graft. (D) Through the compressed true lumen, the tear close to the FET was superselectively cannulated to access the false lumen. (E) A guidewire was then advanced retrograde into the FET stent, establishing a “FET-false lumen-true lumen” pathway. (F) A thoracic endovascular stent was deployed to redirect aortic flow into the true lumen. (G) The aortic angiography confirmed flow through the FET stent and the newly placed stent into the true lumen. (H) The aortic angiography confirmed that the visceral branches were well perfused.

Following TEVAR, the patient's abdominal distension, liver and renal function normalized, and lactate levels decreased. No spinal cord ischemia or stent migration occurred. Follow-up CTA demonstrated significant expansion of the true lumen and shrinkage of the false lumen in the descending aorta (Figure 4). The patient was discharged two weeks later and remained asymptomatic at the 8-month follow-up.

Computed tomography angiography after intervention. **(A)** The three-dimensional reconstruction of the aorta after the intervention showed that the stent had returned to the true lumen. **(B–F)** Follow-up CTA demonstrated significant expansion of the true lumen and shrinkage of the false lumen in the descending aorta. TL, true lumen (red arrow); FL, false lumen; FET, frozen elephant trunk; TEVAR, thoracic endovascular aortic repair.
Figure 4. Computed tomography angiography after intervention. (A) The three-dimensional reconstruction of the aorta after the intervention showed that the stent had returned to the true lumen. (B–F) Follow-up CTA demonstrated significant expansion of the true lumen and shrinkage of the false lumen in the descending aorta. TL, true lumen (red arrow); FL, false lumen; FET, frozen elephant trunk; TEVAR, thoracic endovascular aortic repair.

CFD analysis was performed to evaluate hemodynamic changes before and after thoracic endovascular stent graft placement (Figure 2). The results indicated that, at the end-systole, pressure in the acceding aorta and the false lumen of the descending aorta decreased significantly after TEVAR. Wall shear stress increased in the true lumen and decreased in the false lumen. Blood flow velocity increased significantly in the true lumen and the branch vessels, while decreased in the false lumen. Over the cardiac cycle, flow in the true lumen and the visceral branches increased, whereas flow in the false lumen diminished.

CFD methods

Patient-specific geometries were reconstructed from CTA data using the image analysis software Mimics 21.0 (Materialise, Belgium). Segmentation was performed using a semi-automatic threshold-based method combined with region growing. Following reconstruction, manual corrections were applied to improve the reliability and precision of the segmentation. Unstructured tetrahedral meshes were then generated using ICEM (ANSYS, Canonsburg, Pennsylvania). CFD simulations were conducted using CFX (ANSYS, Canonsburg, Pennsylvania). The velocity and pressure fields were obtained by solving the Navier-Stokes equations under prescribed boundary conditions. For the outlet boundary conditions, a three-element Windkessel model was applied at all outlets. Post-processing and visualization of the simulation results were carried out using CFD-Post (ANSYS, Canonsburg, Pennsylvania).

Comment

In the management of acute type A aortic dissection, the inadvertent deployment of FET into the false lumen resulting in true lumen collapse is a rare but devastating complication (3, 4). This maldeployment can lead to malperfusion of visceral organs, the spinal cord, or the lower extremities, and is associated with high mortality (5, 6). Therefore, rapid recognition and timely, effective intervention are crucial to mitigating the adverse outcomes associated with incorrect stent placement.

Prompt identification of stent malposition is critical for patient salvage. Intraoperatively, routine monitoring of the pressure gradient between upper and lower limb arteries should be performed. Postoperatively, signs of visceral malperfusion, characterized by acute liver and kidney dysfunction, coagulopathy, elevated lactate and myoglobin levels, reduced urine output, and metabolic acidosis, must be closely monitored. If stent malposition is suspected, immediate confirmation with aortic CTA or angiography is mandatory. Once confirmed, emergency intervention is required to address the malperfusion. This may involve additional stent grafting to redirect flow into the true lumen, either through existing intimal tears or via fenestration created between the FET and the celiac artery, effectively establishing a “FET-false lumen-true lumen” pathway (7, 8).

The application of CFD provides valuable visual insights into hemodynamic parameters within the aorta. This modality enables the non-invasive and intuitive quantification of key hemodynamic parameters, including pressure, wall shear stress, flow velocity, flow direction, and volume (9, 10). Through CFD analysis, we can quantitatively assess preoperative and postoperative hemodynamic changes, offering a scientific basis and potential for predicting the outcomes of interventions before they are performed (11, 12).

In summary, when malposition of FET stent is suspected, immediate imaging with CTA or angiography is mandatory. A comprehensive assessment of the anatomy and hemodynamic status is essential to formulate an appropriate intervention strategy. Rapid recognition and timely, effective intervention are paramount to mitigating the risks associated with this serious complication.

Generative AI statement

The author(s) declared that generative AI was not used in the creation of this manuscript.

Any alternative text (alt text) provided alongside figures in this article has been generated by Frontiers with the support of artificial intelligence and reasonable efforts have been made to ensure accuracy, including review by the authors wherever possible. If you identify any issues, please contact us.

Publisher's note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Supplementary material

The Supplementary Material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fcvm.2026.1961251/full#supplementary-material

Emergency endovascular repair procedure for true lumen collapsed. Supplementary material at the source

Angiography of the false lumen before intervention. Supplementary material at the source

Angiography of the true lumen before intervention. Supplementary material at the source

Angiography of the descending aorta after intervention. Supplementary material at the source

Footnotes

Edited by: Christoph Knappich, Helios Klinikum München West, Germany

Reviewed by: Nikolaos Papatheodorou, University Hospital Rechts der Isar, Technical University of Munich, Germany

Mouhammad Kanj, Lebanese University, Lebanon

Statements

Conflict of interest

The author(s) declared that this work was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Funding

The author(s) declared that financial support was received for this work and/or its publication. This work was supported by the National Natural Science Foundation of China (No. 82374240), the Scientific Research Initiation Project of Guangdong Provincial Hospital of Traditional Chinese Medicine (No. 2021KT1709), Outstanding Clinical Technical Talent Program of Guangdong Provincial Hospital of Chinese Medicine (No. E60803, No. E60824) and Medical Scientific Research Foundation of Guangdong Province (No. A2025247).

Data availability

The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.

Ethics approval

The studies involving humans were approved by the Guangdong Provincial Hospital of Chinese Medicine Ethics Committee approved this retrospective review (ZE2022-303-01; approved October 11, 2022). The studies were conducted in accordance with the local legislation and institutional requirements. Written informed consent was obtained from the individual(s) for the publication of any potentially identifiable images or data included in this article.

Author contributions

XF: Conceptualization, Investigation, Methodology, Validation, Writing – original draft, Writing – review & editing. KH: Formal analysis, Writing – original draft, Writing – review & editing. WX: Data curation, Investigation, Methodology, Validation, Writing – review & editing. ZZ: Data curation, Software, Validation, Writing – review & editing. NA: Data curation, Writing – review & editing. GW: Investigation, Methodology, Project administration, Resources, Writing – review & editing. CW: Conceptualization, Investigation, Methodology, Software, Validation, Writing – original draft, Writing – review & editing.

Acknowledgements

We are grateful to all members who contributed to the study.

References

  1. 1. Ma W-G, Chen Y, Chen S-W, Zhang W, Zheng J, Li Q-G. Frozen elephant trunk for acute type A aortic dissection: long-term outcomes over two decades. Eur Heart J. (2026) 47 (20): 2452 – 65. doi:10.1093/eurheartj/ehaf1117
  2. 2. Iafrancesco M, Goebel N, Mascaro J, Franke UFW, Pacini D, Di Bartolomeo R. Aortic diameter remodelling after the frozen elephant trunk technique in aortic dissection: results from an international multicentre registry. Eur J Cardiothorac Surg. (2017) 52 (2): 310 – 8. doi:10.1093/ejcts/ezx131
  3. 3. Lee HM, Li YS, Li ML. Inadvertent placement of thoracic stent-grafts in false lumen during aortic dissection surgery-unicentric analysis and systematic review. Int J Surg. (2025) 111: 8529 – 39. doi:10.1097/JS9.0000000000003028
  4. 4. Raupach J, Chovanec V, Kozakova V, Vojacek J. Endovascular fenestration of aortic dissection membrane after failed frozen elephant trunk procedure. Eur J Cardiothorac Surg. (2020) 57 (3): 598 – 600. doi:10.1093/ejcts/ezz251
  5. 5. Kawashima M, Nomura Y, Matsumori M, Murakami H. Bail-out thoracic endovascular aortic repair for incorrect deployment of frozen elephant trunk into the false lumen. Interact Cardiovasc Thorac Surg. (2020) 30 (6): 947 – 9. doi:10.1093/icvts/ivaa043
  6. 6. Dell’Aquila AM, Wisniewski K, Georgevici A-I, Szabó G, Onorati F, Rossetti C. Malperfusion syndrome in patients undergoing repair for acute type A aortic dissection: presentation, mortality, and utility of the penn classification. J Thorac Cardiovasc Surg. (2025) 170 (3): 687 – 97. doi:10.1016/j.jtcvs.2024.11.003
  7. 7. Plotkin A, Hanks SE, Han SM, Fleischman F, Weaver FA, Magee GA. Endovascular septal fenestration using a radiofrequency wire to salvage inadvertent false lumen deployment of a frozen elephant trunk stent graft. J Vasc Surg Cases Innov Tech. (2019) 5 (4): 553 – 6. doi:10.1016/j.jvscit.2019.07.011
  8. 8. Isselbacher EM, Preventza O, Hamilton Black J 3rd, Augoustides JG, Beck AW, Bolen MA. ACC/AHA guideline for the diagnosis and management of aortic disease: a report of the American Heart Association/American College of Cardiology joint committee on clinical practice guidelines. Circulation. (2022) 146 (24): e334 – 482. doi:10.1161/CIR.0000000000001106
  9. 9. Hu M, Chen B, Luo Y. Computational fluid dynamics modelling of hemodynamics in aortic aneurysm and dissection: a review. Front Bioeng Biotechnol. (2025) 13: 1556091. doi:10.3389/fbioe.2025.1556091
  10. 10. Papakonstantinou NA, Martinez-Lopez D, Chung JC. The frozen elephant trunk: seeking a more definitive treatment for acute type A aortic dissection. Eur J Cardiothorac Surg. (2024) 65 (5): ezae176. doi:10.1093/ejcts/ezae176
  11. 11. Wang C, Zou R, Lv L, Wang G, Fan X. Computational fluid dynamic-assisted analysis for residual aortic dissection after thoracic endovascular aortic repair. Eur Heart J Cardiovasc Imaging. (2023) 24 (12): e302. doi:10.1093/ehjci/jead211
  12. 12. Zorrilla R, Soudah E, Rossi R. Computational modeling of the fluid flow in type B aortic dissection using a modified finite element embedded formulation. Biomech Model Mechanobiol. (2020) 19 (5): 1565 – 83. doi:10.1007/s10237-020-01291-x

Citation

Fan, X., et al. (2026). Case Report: Endovascular repair for true lumen collapse after frozen elephant trunk for type A aortic dissection. Frontiers in Cardiovascular Medicine, Volume 13. https://doi.org/
Received
Accepted
Published
Volume
13 - 2026

Copyright

© 2026 Fan, He, Xu, Zou, Abudurexiti, Wang and Wang.

License: https://creativecommons.org/licenses/by/4.0/

*Correspondence: Ge Wang; Chaojie Wang

Article metrics

Views
0
Downloads
0
Citations
0
Shares
0