Neuroenergetics
Frontiers in Neuroenergetics ·
Volume 4 - 2012 | https://doi.org/10.3389/fnene.2012.00006
Image Quality Analysis of High-Density Diffuse Optical Tomography Incorporating a Subject-Specific Head Model
- Yuxuan Zhan1
- Adam T. Eggebrecht2
- Joseph P. Culver2
- Hamid Dehghani1*corresponding author
- 11 School of Computer Science, University of Birmingham Birmingham, UK
- 22 Department of Radiology, Washington University School of Medicine St. Louis, MO, USA
Abstract
High-density diffuse optical tomography (HD-DOT) methods have shown significant improvement in localization accuracy and image resolution compared to traditional topographic near infrared spectroscopy of the human brain. In this work we provide a comprehensive evaluation of image quality in visual cortex mapping via a simulation study with the use of an anatomical head model derived from MRI data of a human subject. A model of individual head anatomy provides the surface shape and internal structure that allow for the construction of a more realistic physical model for the forward problem, as well as the use of a structural constraint in the inverse problem. The HD-DOT model utilized here incorporates multiple source-detector separations with continuous-wave data with added noise based on experimental results. To evaluate image quality we quantify the localization error and localized volume at half maximum (LVHM) throughout a region of interest within the visual cortex and systematically analyze the use of whole-brain tissue spatial constraint within image reconstruction. Our results demonstrate that an image quality with less than 10 mm in localization error and 1000 m 3 in LVHM can be obtained up to 13 mm below the scalp surface with a typical unconstrained reconstruction and up to 18 mm deep when a whole-brain spatial constraint based on the brain tissue is utilized.
Keywords
References
- Arridge S. R. (1999). Optical tomography in medical imaging. Inverse Probl. 15, R14 – R93. doi:10.1088/0266-5611/15/2/022
- Bevilacqua F., Piguet D., Marquet P., Gross J. D., Tromberg B. J., Depeursinge C. (1999). In vivo local determination of tissue optical properties: applications to human brain. Appl. Opt. 38, 4939 – 4950. doi:10.1364/AO.38.004939
- Bluestone A., Abdoulaev G., Schmitz C., Barbour R., Hielscher A. (2001). Three-dimensional optical tomography of hemodynamics in the human head. Opt. Express 9, 272 – 286. doi:10.1364/OE.9.000272
- Boas D. A., Chen K., Grebert D., Franceschini M. A. (2004a). Improving the diffuse optical imaging spatial resolution of the cerebral hemodynamic response to brain activation in humans. Opt. Lett. 29, 1506 – 1508. doi:10.1364/OL.29.001506
- Boas D. A., Dale A. M., Franceschini M. A. (2004b). Diffuse optical imaging of brain activation: approaches to optimizing image sensitivity, resolution, and accuracy. Neuroimage 23 (Suppl. 1), S275 – S288. doi:10.1016/j.neuroimage.2004.07.011
- Boas D. A., Dale A. M. (2005). Simulation study of magnetic resonance imaging-guided cortically constrained diffuse optical tomography of human brain function. Appl. Opt. 44, 1957 – 1968. doi:10.1364/AO.44.001957
- Brooksby B., Jiang S., Dehghani H., Pogue B. W., Paulsen K. D., Weaver J., Kogel C., Poplack S. P. (2005). Combining near-infrared tomography and magnetic resonance imaging to study in vivo breast tissue: implementation of a Laplacian-type regularization to incorporate magnetic resonance structure. J. Biomed. Opt. 10, 051504. doi:10.1117/1.2098627
- Culver J. P., Siegel A. M., Stott J. J., Boas D. A. (2003). Volumetric diffuse optical tomography of brain activity. Opt. Lett. 28, 2061 – 2063. doi:10.1364/OL.28.002061
- Custo A., Boas D. A., Tsuzuki D., Dan I., Mesquita R., Fischl B., Grimson W. E., Wells W. III. (2010). Anatomical atlas-guided diffuse optical tomography of brain activation. Neuroimage 49, 561 – 567. doi:10.1016/j.neuroimage.2009.07.033
- Custo A., Wells W. M. III, Barnett A. H., Hillman E. M., Boas D. A. (2006). Effective scattering coefficient of the cerebral spinal fluid in adult head models for diffuse optical imaging. Appl. Opt. 45, 4747 – 4755. doi:10.1364/AO.45.004747
- Dehghani H., Eames M. E., Yalavarthy P. K., Davis S. C., Srinivasan S., Carpenter C. M., Pogue B. W., Paulsen K. D. (2008). Near infrared optical tomography using NIRFAST: algorithm for numerical model and image reconstruction. Commun. Numer. Methods Eng. 25, 711 – 732. doi:10.1002/cnm.1162
- Dehghani H., Srinivasan S., Pogue B. W., Gibson A. (2009a). Numerical modelling and image reconstruction in diffuse optical tomography. Philos. Transact. A Math. Phys. Eng. Sci. 367, 3073 – 3093. doi:10.1098/rsta.2009.0090
- Dehghani H., White B. R., Zeff B. W., Tizzard A., Culver J. P. (2009b). Depth sensitivity and image reconstruction analysis of dense imaging arrays for mapping brain function with diffuse optical tomography. Appl. Opt. 48, D137 – D143. doi:10.1364/AO.48.00D137
- Eggebrecht A. T., White B. R., Ferradal S. L., Chen C., Zhan Y., Snyder A. Z., Dehghani H., Culver J. P. (2012). A quantitative spatial comparison of high-density diffuse optical tomography and fMRI cortical mapping. Neuroimage. doi:10.1016/j.neuroimage.2012.01.124
- Gibson A. P., Austin T., Everdell N. L., Schweiger M., Arridge S. R., Meek J. H., Wyatt J. S., Delpy D. T., Hebden J. C. (2006). Three-dimensional whole-head optical tomography of passive motor evoked responses in the neonate. Neuroimage 30, 521 – 528. doi:10.1016/j.neuroimage.2005.08.059
- Heiskala J., Hiltunen P., Nissila I. (2009a). Significance of background optical properties, time-resolved information and optode arrangement in diffuse optical imaging of term neonates. Phys. Med. Biol. 54, 535 – 554. doi:10.1088/0031-9155/54/3/005
- Heiskala J., Pollari M., Metsaranta M., Grant P. E., Nissila I. (2009b). Probabilistic atlas can improve reconstruction from optical imaging of the neonatal brain. Opt. Express 17, 14977 – 14992. doi:10.1364/OE.17.014977
- Koch S. P., Habermehl C., Mehnert J., Schmitz C. H., Holtze S., Villringer A., Steinbrink J., Obrig H. (2010). High-resolution optical functional mapping of the human somatosensory cortex. Front Neuroenergetics 2: 12. doi:10.3389/fnene.2010.00012
- Li T., Gong H., Luo Q. (2011). Visualization of light propagation in visible Chinese human head for functional near-infrared spectroscopy. J. Biomed. Opt. 16, 045001. doi:10.1117/1.3625288
- Niu H., Khadka S., Tian F., Lin Z. J., Lu C., Zhu C., Liu H. (2011). Resting-state functional connectivity assessed with two diffuse optical tomographic systems. J. Biomed. Opt. 16, 046006. doi:10.1117/1.3561687
- Obrig H., Villringer A. (2003). Beyond the visible – imaging the human brain with light. J. Cereb. Blood Flow Metab. 23, 1 – 18.
- O’Leary M. A. (1996). Imaging with Diffuse Photon Density Waves. Ph.D. thesis, University of Pennsylvania, Philadelphia.
- Penrose R. (1955). A generalized inverse for matrices. Proc. Camb. Philos. Soc. 51, 406 – 413. doi:10.1017/S0305004100030401
- Pogue B. W., Davis S. C., Song X., Brooksby B. A., Dehghani H., Paulsen K. D. (2006). Image analysis methods for diffuse optical tomography. J. Biomed. Opt. 11, 33001. doi:10.1117/1.2335429
- Strangman G., Franceschini M. A., Boas D. A. (2003). Factors affecting the accuracy of near-infrared spectroscopy concentration calculations for focal changes in oxygenation parameters. Neuroimage 18, 865 – 879. doi:10.1016/S1053-8119(03)00021-1
- White B. R., Culver J. P. (2010a). Phase-encoded retinotopy as an evaluation of diffuse optical neuroimaging. Neuroimage 49, 568 – 577. doi:10.1016/j.neuroimage.2009.07.023
- White B. R., Culver J. P. (2010b). Quantitative evaluation of high-density diffuse optical tomography: in vivo resolution and mapping performance. J. Biomed. Opt. 15, 026006. doi:10.1117/1.3368999
- White B. R., Snyder A. Z., Cohen A. L., Petersen S. E., Raichle M. E., Schlaggar B. L., Culver J. P. (2009). Resting-state functional connectivity in the human brain revealed with diffuse optical tomography. Neuroimage 47, 148 – 156. doi:10.1016/j.neuroimage.2009.03.058
- Zeff B. W., White B. R., Dehghani H., Schlaggar B. L., Culver J. P. (2007). Retinotopic mapping of adult human visual cortex with high-density diffuse optical tomography. Proc. Natl. Acad. Sci. U.S.A. 104, 12169 – 12174. doi:10.1073/pnas.0611266104
- Zhan Y., Eggebrecht A., Dehghani H., Culver J. (2011). Quantitative evaluation of systematic imaging error due to uncertainty in tissue optical properties in high-density diffuse optical tomography. Proc. SPIE 7896, 78960O.
Citation
Zhan, Y., et al. (2012). Image Quality Analysis of High-Density Diffuse Optical Tomography Incorporating a Subject-Specific Head Model. Frontiers in Neuroenergetics, Volume 4. https://doi.org/
- Received
- Accepted
- Published
- Volume
- 4 - 2012
Copyright
Copyright © 2012 Zhan, Eggebrecht, Culver and Dehghani.
License: http://www.frontiersin.org/licenseagreement
*Correspondence: Hamid Dehghani
Article metrics
- Views
- 0
- Downloads
- 0
- Citations
- 0
- Shares
- 0