Skip to content

Correction

Frontiers in Human Neuroscience ·

Volume 20 - 2026 | https://doi.org/10.3389/fnhum.2026.1995038

Correction: Perioperative management for invasive brain–computer interface implantation under surgical navigation in a patient with traumatic spinal cord injury: a case report

  • Shuhui Yang1,2
  • Qiang Sun1,2
  • Hong Mo2,3
  • Wenyao Cui1,2*corresponding author
  1. 1Department of Neurosurgery, West China Hospital, Sichuan University, Chengdu, China
  2. 2West China School of Nursing, Sichuan University, Chengdu, China
  3. 3Department of Anesthesiology, West China Hospital, Sichuan University, Chengdu, China
Article metrics0 viewsView details

Abstract

Keywords

In the original publication, the ARAT scores were reported without clearly specifying the assessment condition (with or without BCI assistance). Upon post-publication review, the authors identified that the reported scores should have been described as those obtained with the assistance of the BCI system. The text has been revised accordingly to accurately reflect the assessment condition and to report the correct left-hand grasp ARAT score with BCI assistance.

A correction has been made to the section (1) the Case summary in the Abstract; (2) Point 2 in the section “1 What does this paper contribute to the wider global clinical community?”; and (3) the second-to-last paragraph of subsection “2.2 Treatment course and outcomes” under section 2 Clinical materials:

“(1) At the 6-month follow-up, the patient's left-hand brain–computer interface-assisted grasping score was 18 points.; (2) At the 6-month follow-up, the patient's left-hand brain–computer interface-assisted grasping score was 18 points. This finding is expected to promote the wide application of brain–computer interfaces in patients with spinal cord injuries; (3) Before surgery, the patient's left-hand grasping score was 2 point. The device was activated on August 13, 2025, at which time all impedance values were within normal limits. The channel impedances were measured as 841, 976, 886, 732, 774, 926, 891, and 803 Ω. At the 2-month follow-up on September 19, 2025, device impedance remained normal, with channel impedances of 1,327, 1,591, 1,556, 1,175, 1,516, 1,612, 1,489, and 1,489 Ω. The patient's left-hand BCI-assisted grasping score was 17 points. At the 3-month follow-up, device impedance remained normal, with channel impedances of 1,482, 1,685, 1,612, 1,462, 1,647, 1,630, 1,604, and 1,552 Ω. The patient's left-hand BCI-assisted grasping score was 18 points. At the 6-month follow-up, device impedance remained normal, with channel impedances of 1,490, 1,646, 1,626, 1,489, 1,688, 1,698, 1,625, and 1,559 Ω. The patient's left-hand BCI-assisted grasping score was 18 points. No adverse events occurred following the brain–computer interface implantation, and the patient reported high satisfaction. The therapeutic flowchart is presented in Figure 2.”

The original version of this article has been updated.

Publisher's note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Footnotes

Edited and reviewed by: Floriana Pichiorri, Santa Lucia Foundation (IRCCS), Italy

Citation

Yang, S., et al. (2026). Correction: Perioperative management for invasive brain–computer interface implantation under surgical navigation in a patient with traumatic spinal cord injury: a case report. Frontiers in Human Neuroscience, Volume 20. https://doi.org/
Received
Accepted
Published
Volume
20 - 2026

Copyright

Copyright © 2026 Yang, Sun, Mo and Cui.

License: https://creativecommons.org/licenses/by/4.0/

*Correspondence: Wenyao Cui

Article metrics

Views
0
Downloads
0
Citations
0
Shares
0