Skip to content

Review

Frontiers in Pain Research ·

Volume 7 - 2026 | https://doi.org/10.3389/fpain.2026.1901466

Electromagnetic neuromodulation for chronic pain: historical context, contemporary modalities, and evidence gaps

  • Laura Dipietro1*corresponding author
  • Ciro Ramos-Estebanez2
  • Paola Gonzalez-Mego3
  • Anna Carolyna Gianlorenco3,4
  • Arisara Wongtanawat2
  • Christopher Robinson5
  • Salim M. Hayek6,7
  • Felipe Fregni3,4
  • Timothy Wagner1,8
  1. 1Highland Instruments, Cambridge, MA, United States
  2. 2Departments of Neurology and Rehabilitation, and Neurosurgery, University of Illinois at Chicago, Chicago, IL, United States
  3. 3Spaulding Neuromodulation Center, Spaulding Rehabilitation Hospital and Massachusetts General Hospital, Boston, MA, United States
  4. 4Department of Physical Medicine and Rehabilitation, Harvard Medical School, Boston, MA, United States
  5. 5Division of Pain, Department of Anesthesiology and Critical Care Medicine, Johns Hopkins University School of Medicine, Baltimore, MD, United States
  6. 6Division of Pain Medicine, University Hospitals Cleveland Medical Center, Cleveland, OH, United States
  7. 7Department of Anesthesiology, Case Western Reserve University, Cleveland, OH, United States
  8. 8Harvard-MIT Program in Health Sciences and Technology, Cambridge, MA, United States
Article metrics0 viewsView details

Abstract

Electromagnetic neuromodulation is increasingly used as an adjunct or alternative to pharmacologic therapy for pain, with several approaches cleared for select indications and many others under active investigation. We review implanted neuromodulation approaches (intracranial and spinal), vagal neuromodulation, noninvasive central/cranial neuromodulation, peripheral neuromodulation, and hybrid/multimodal approaches, with a primary focus on chronic pain management and brief coverage of selected acute-use indications (e.g., primary headache disorders) where relevant. Beyond summarizing individual modalities, we highlight the recurring patterns that have shaped the evolution of pain neuromodulation. For each modality, we summarize putative mechanism of action, typical stimulation paradigms, and key strengths and limitations of the clinical evidence, emphasizing sources of heterogeneity that complicate cross-study comparison and translation. We conclude by outlining priorities for the field, including more rigorous trial design, standardized reporting of stimulation parameters and outcomes, and clearer indication-specific evidence to support clinical translation.

Keywords

1 Introduction: from early electroanalgesia to modern neuromodulation

Pharmacologic therapy is widely used to treat chronic pain, but its clinical utility is often limited by incomplete efficacy, adverse effects, and, for some agents, risks of misuse and dependence. In response to these limitations, electrical and magnetic neuromodulation approaches have emerged as adjunctive or alternative strategies for pain management, with several technologies cleared or approved by the Food and Drug Administration (FDA) for select pain indications. This review focuses on invasive and noninvasive neuromodulation methods, in which the therapeutic stimulus is principally electrical or magnetic, broadly considered here under the umbrella of electromagnetic neuromodulation, with emphasis on their application to chronic pain.

The first recorded use of electricity in medicine is commonly attributed to Scribonius Largus, who in Compositiones (around AD 47) described the use of a live torpedo fish to treat gout pain and headache (1, 2). The therapeutic use of electric fish persisted into late antiquity, and Galen also discussed the torpedo fish in relation to pain relief (3). Later developments replaced animal-derived electricity with man-made electrical sources. In the 1700s, Leyden jars (4), an early precursor to batteries, were explored as an electrical source for therapeutic pain relief (5). Work by Galvani and Aldini also helped establish electrical stimulation as an experimental tool for probing neuromuscular and brain function (6–8). In the late 1800s and early 1900s, electrical instruments were deployed for a variety of pain therapies, culminating in a chapter on “Electrical Analgesia, Sleep, and Resuscitation” in Gwathmey and Baskerville's 1914 “Anesthesia” textbook (9).

Electrical stimulation for pain entered the modern era in the late 1960s, amid broader interest in transcranial “electrical anesthesia,” when Reynolds demonstrated that microstimulation of the rat midbrain central gray could produce analgesia (10). Human case reports soon followed, describing analgesic effects of stimulation targeting the internal capsule (IC) (11) and periventricular/periaqueductal gray (PVG/PAG) (12, 13). The advent of modern noninvasive brain stimulation further expanded the field. Following the demonstration of noninvasive magnetic stimulation of human motor cortex in 1985 (14), repetitive transcranial magnetic stimulation (rTMS) protocols were subsequently explored as analgesic interventions, initially emphasizing the primary motor cortex (M1) and later extending to prefrontal and parietal targets to engage both sensory–discriminative and cognitive–affective dimensions of pain.

Conceptual advances in pain neuroscience also shaped device development: the gate control theory of pain proposed by Melzack and Wall (15) provided a mechanistic framework for why activation of large-diameter afferents might inhibit nociceptive transmission, helping motivate the clinical uptake of peripheral and spinal stimulation approaches. Moreover, these ideas, together with evolving concepts of descending pain modulation and, later, central sensitization, supported interest in cortical and supraspinal targets for analgesia (16–18). These developments helped establish electromagnetic neuromodulation as a broader strategy for pain management, with several technologies cleared for specific chronic pain conditions and acute-use applications, most prominently primary headache disorders.

Pain processing is distributed across multiple interacting levels of the nervous system rather than being confined to a single anatomical site. Peripheral noxious stimuli are transduced by nociceptors and conveyed primarily by thinly myelinated Aδ and unmyelinated C fibers (19) to the dorsal horn, where segmental gating, convergence of nociceptive and non-nociceptive inputs, and activity-dependent sensitization shape onward transmission (15, 16, 18, 20–22). Ascending pathways relay signals to thalamic, somatosensory, insular, cingulate, and related limbic-cortical regions involved in the sensory, affective, attentional, and evaluative dimensions of pain (23–26). In parallel, descending modulatory systems involving structures such as the PAG, rostral ventromedial medulla (RVM), and brainstem monoaminergic pathways can suppress or facilitate nociceptive processing (27, 28). In chronic pain states, maladaptive plasticity may emerge across this system, including central sensitization, impaired inhibitory control, abnormal facilitation, and altered network-level processing (29). This framework provides a rationale for organizing electromagnetic neuromodulation strategies according to their primary anatomical targets, while recognizing that many ultimately exert distributed downstream effects across the broader pain network.

Pain can further be classified in several ways, including by duration (acute or chronic) and by dominant mechanism (nociceptive, neuropathic, or central), although these categories often overlap in clinical practice. We use the term chronic to refer to pain that persists long enough to permit maladaptive changes within the nervous system, including central sensitization (29). Mechanistically, however, ample evidence shows that pain definitions are not mutually exclusive and instead share overlapping features; moreover, shared pathophysiology may add to the overlap of pain syndromes (18, 29–32). As a result, clinicians frequently encounter patients with mixed mechanisms for pain. Specifically, conditions originating in the periphery can induce central sensitization (16, 18, 32), i.e., neuroplastic changes associated with remodeling, reorganization, and altered neural excitability of the central nervous system (26, 33–38). Within this overlapping mechanistic framework, neuromodulation strategies can be considered according to where they act along the pain pathway: in the periphery [e.g., peripheral nerve stimulation (PNS)], along ascending pathways [e.g., TENS or spinal cord stimulation (SCS)], indirectly through cortical network effects [e.g., motor cortex stimulation (MCS) over M1, thought to ultimately influence the PAG and RVM], and/or directly within the brain [e.g., deep brain stimulation (DBS) implanted in the PAG]. Thus, as part of this review, we also consider the hypothesized mechanisms of action of each stimulation modality, although these mechanisms remain incompletely understood and, in many cases, debated. Figure 1 summarizes major conceptual milestones alongside key device innovations in electromagnetic neuromodulation.

Timeline of electromagnetic neuromodulation for pain, showing major technological developments (top) and corresponding advances in neuroscience (bottom). The figure highlights the progression from empirical electro-analgesia to contemporary neuromodulation approaches, alongside evolving mechanistic frameworks of pain modulation.
Figure 1. Timeline of electromagnetic neuromodulation for pain, showing major technological developments (top) and corresponding advances in neuroscience (bottom). The figure highlights the progression from empirical electro-analgesia to contemporary neuromodulation approaches, alongside evolving mechanistic frameworks of pain modulation.

The sections below are organized by modality and principal anatomical target, while also situating each approach within its historical development and current evidence base. Figure 2 provides a schematic overview of the principal electromagnetic neuromodulation modalities discussed below, organized by anatomical target and mode of delivery.

Schematic overview of major electromagnetic neuromodulation modalities for pain, organized by anatomical target and mode of delivery.
Figure 2. Schematic overview of major electromagnetic neuromodulation modalities for pain, organized by anatomical target and mode of delivery.

Given the breadth of the field, this review integrates modalities with differing levels of clinical maturity, evidence strength, and regulatory status to provide a cross-modality perspective on how electromagnetic neuromodulation is currently applied and evolving in pain medicine. We emphasize a recurring pattern in which early mechanistic models drive technological innovation and subsequent clinical adoption, followed by heterogeneous outcomes that stimulate an iterative process of updated knowledge of pain physiology and subsequent device optimization towards better clinical outcomes. In addition to summarizing the historical development, mechanisms, regulatory status, and clinical applications of these modalities, this review highlights evidence gaps that limit interpretation and translation of the current literature. By synthesizing these limitations across electromagnetic neuromodulation approaches, we aim to clarify where these technologies have shown clinical promise and where stronger evidence is needed.

1.1 Scope and literature search strategy

This narrative review examines the historical development, current clinical use, and remaining evidence gaps in electromagnetic neuromodulation for pain management, with primary emphasis on chronic pain. The review includes implanted and noninvasive approaches acting across the peripheral, spinal, autonomic, cranial/transcranial, cortical, and intracranial levels of the nervous system, as well as selected combined approaches. Selected short-term or acute-use paradigms, such as transcutaneous electrical nerve stimulation (TENS) and noninvasive vagal nerve stimulation (nVNS) for acute migraine and cluster headache episodes, are briefly noted when they help contextualize the development or regulatory status of technologies also relevant to chronic pain. Because several electromagnetic neuromodulation devices carry regulatory indications spanning both chronic pain and episodic headache disorders, FDA-cleared or approved uses are summarized separately for chronic and acute/episodic indications in Tables 1, 2. The sections that follow, together with Table 3, address the broader literature, including applications beyond current regulatory labeling.

Table 1. FDA-cleared/approved electromagnetic neuromodulation devices for chronic pain.

ModalityFDA decision dateFDA-authorized use (summary)aApplicantDeviceAuthorization typeSource
SCS11/30/84Chronic intractable pain of the trunk and/or limbsMedtronicMultiple generations via supplements of PMA P840001; legacy: Itrel/Itrel 3/SynergyPMAFDA PMA P840001
SCS11/21/01Chronic intractable pain of the trunk and/or limbsAdvanced Neuromodulation Systems (ANS); later St. Jude Medical; now AbbottMultiple generations via supplements of PMA P010032; legacy: Genesis/Eon/Prodigy/Proclaim (incl. XR/Plus)/EternaPMAFDA PMA P010032
SCS4/27/04Chronic intractable pain of the trunk and/or limbsAdvanced Bionics; now Boston ScientificMultiple generations via supplements of PMA P030017; legacy/platforms include Precision/Precision Spectra/Precision Novi/Precision Montage (MRI)/Spectra WaveWriter/WaveWriter Alpha (Prime)PMAFDA PMA P030017
SCS5/8/15Chronic intractable pain of the trunk and/or limbsNevro CorporationMultiple generations via supplements of PMA P130022; platforms include: Senza/Senza II/Senza Omnia (10 kHz SCS)PMAFDA PMA P130022
SCS11/20/15Chronic intractable pain of the trunk and/or limbsNuvectra CorporationMultiple generations via supplements of PMA P130028; platform: Algovita™ SCS System (legacy product line)PMAFDA PMA P130028
SCS2/28/22Chronic intractable pain of the trunk and/or limbsSaluda MedicalMultiple generations via supplements of PMA P190002; platform: Evoke® SCS System (evoked compound action potential (ECAP) controlled closed-loop)PMAFDA PMA P190002
SCS3/31/23Chronic intractable pain in the trunk and/or limbsBiotronik Nro, IncMultiple generations via supplements of PMA P210037; platform: Prospera™ SCS SystemPMAFDA PMA P210037
DRG2/11/16CRPS I/IIAbbott MedicalAxium Neurostimulator System; later supplements under P150004 include Proclaim DRG devicesPMAFDA PMA P150004
Implanted PNS2/20/15Severe intractable chronic pain of peripheral nerve origin (adjunct to other therapies)Bioness, IncStimRouter Neuromodulation System510(k)FDA 510(k) K142432
Implanted PNS3/29/19Chronic, intractable pain of peripheral nerve originNalu Medical, IncNalu Neurostimulation System510(k)FDA 510(k) K183579
Implanted PNS6/20/24Chronic, intractable pain of peripheral nerve originCuronixFreedom PNS System510(k)FDA 510(k) K233162
Implanted PNS8/27/21Severe intractable chronic pain of peripheral nerve originNeuspera Medical, IncNeuspera Neurostimulation System510(k)FDA 510(k) K202781
Implanted PNS3/11/16Severe intractable chronic pain of peripheral nerve originStimQ, LLCStimQ510(k)FDA 510(k) K152178
Restorative neurostimulation (implanted neuromuscular stimulation—multifidus)6/16/20Intractable chronic low back pain associated with multifidus muscle dysfunction (adults; failed therapy; not candidates for spine surgery)Mainstay Medical LimitedReActiv8PMAFDA PMA P190021
TENS8/30/24Chronic intractable pain; post-traumatic and post-surgical painTensCare LtdUnipro510(k)FDA 510(k) K232441
TENS2/23/24Chronic intractable pain; temporary relief of musculoskeletal pain (sore/aching muscles)Hinge Health, IncENSO (Model 2)510(k)FDA 510(k) K233784

Representative devices organized by modality and labeled indication, spanning invasive spinal neuromodulation (SCS, DRG stimulation), peripheral neuromodulation (implanted PNS; restorative multifidus neurostimulation), and transcutaneous approaches (TENS) with chronic pain labeling. “Authorization type” reflects the primary U.S. regulatory pathway [PMA vs 510(k)]; device generations are often updated via supplements/iterations under the same regulatory file. Applicant names reflect the original PMA holder where historically relevant, with current successor companies noted when applicable. This table is not intended to be exhaustive, particularly for categories with numerous substantially equivalent 510(k) devices (e.g., TENS).

Use statements were summarized and harmonized from FDA marketing authorization documents for comparability and may not reproduce the exact original wording.

Table 2. FDA-cleared/approved electromagnetic neuromodulation devices for acute pain indications.

ModalityFDA decision dateFDA-authorized use (summary)aApplicantDeviceAuthorization typeSourceNotes
TENS10/13/16Temporary relief of sore/aching muscle pain (strain-related musculoskeletal pain)Counter Scientific Development (GZ) LtdOTC TENS Device, Model PTS-IV510(k)FDA 510(k) K161537
TENS6/3/16Adjunctive treatment for post-surgical and post-trauma acute painDjo, LLCStrive510(k)FDA 510(k) K153704Also indicated for chronic intractable pain and arthritis pain
TENS12/6/11Acute pain; post-surgical painElectronic Waveform Lab, IncH-Wave510(k)FDA 510(k) K112485Also indicated for chronic pain
TENS3/27/24Post-surgical and post-traumatic acute painWuxi Jiajian Medical Instrument Co., LtdTENS WMPS2-1510(k)FDA 510(k) K231425Also indicated for chronic intractable pain
TENS component of Combo Stimulator7/29/11Symptomatic relief of acute post-surgical and posttraumatic painHandelshaus Dittman GmbHETG 255 Combo Stimulator/TEN 260 Stimulator510(k)FDA 510(k) K110390Also indicated for chronic intractable pain
Temporary percutaneous PNS1/25/23Post-operative and post-traumatic acute pain; up to 60 daysSPR Therapeutics, IncSPRINT510(k)FDA 510(k) K223306Also indicated for chronic, intractable pain
Auricular percutaneous electrical nerve stimulation (PENS)1/31/22Post-operative pain following cesarean section delivery; up to 3 daysDyAnsys, IncPrimary Relief510(k)FDA 510(k) K213188
TMS (single-pulse, sTMS)12/13/13acute treatment of pain associated with migraine headache with aura.eNeura TherapeuticsNeuralieve Cerena Transcranial Magnetic StimulatorDe NovoFDA De Novo DEN130022Linked 510(k): K130556
External trigeminal nerve stimulation9/15/17Acute treatment of migraine with or without auraCefaly TechnologyCefaly Acute510(k)FDA 510(k) K171446
nVNS11/27/18Acute treatment of pain associated with migraine headache; also episodic cluster headache painelectroCore, IncgammaCore Sapphire510(k)FDA 510(k) K182369Also labeled for adjunctive preventive treatment of episodic cluster headache
Remote Electrical Neuromodulation (REN)1/22/21Acute treatment of migraine with or without auraTheranica Bio-Electronics, LtdNerivio510(k)FDA 510(k) K203181Prescription, home-use REN; indicated for migraine (≥12 years)
External trigeminal + occipital nerve stimulation (cranial TENS)2/16/21Acute treatment of migraine with or without auraNeurolief, LtdRelivion MG510(k)FDA 510(k) K203419

Representative devices organized by modality and labeled acute-use indication, including acute post-operative/post-traumatic pain (TENS; temporary percutaneous PNS; auricular PENS) and acute primary headache disorders (sTMS; external trigeminal stimulation; noninvasive vagus nerve stimulation; remote electrical neuromodulation; cranial trigeminal + occipital stimulation). “Authorization type” reflects the primary U.S. regulatory pathway [510(k) vs De Novo]. Where applicable, the labeled duration of use (e.g., up to 3 days or up to 60 days) is noted. This table is not intended to be exhaustive for device families with multiple substantially equivalent clearances.

Use statements were summarized and harmonized from FDA marketing authorization documents for comparability and may not reproduce the exact original wording.

Table 3. Representative clinical evidence for electromagnetic neuromodulation modalities in pain.

ModalityPain condition/PopulationMethodsTargetStudy type/Evidence levelOutcomesDirection/SizeSafetyAuthor (first)/Year
SCSChronic pain (mixed conditions)SCS vs conventional medical management (CMM); includes direct and indirect comparisons across SCS typesSpinal cord pathways (dorsal columns/dorsal horn circuits)Systematic review + network meta-analysis of RCTsPain intensity; ≥50% pain responder rate; physical function; health-related quality of life (HRQoL)All SCS types were superior to CMM for pain intensity at last follow-up (mean difference range −2.37 to −5.55 on 0–10 scale) and for ≥50% pain relief [Odds ratio (OR) range 9.75–63.4]; HRQoL also improvedSafety not quantitatively synthesized; adverse event (AE) reporting was limited/inconsistent across trialsEldabe 2026 (223)
SCSIntractable spine and limb painImplanted spinal stimulation vs medical therapy (MT); indirect comparison of newer tech vs conventional via common comparatorSpinal cord pathways (dorsal columns/dorsal horn circuits)Systematic review of RCTs + meta-analysis≥50% pain relief; pain intensity [visual analog scale (VAS)]SCS vs MT: ↑ ≥50% pain relief (OR 13.01, 95% confidence interval (CI) 4.96–34.17); VAS ↓ ([weighted mean difference (WMD) 1.43, 95% CI 0.16–2.71). Newer tech (10 kHz/burst/DRG] vs conventional: ↑ pain relief (OR 2.07, 95% CI 1.35–3.19)AEs mainly hardware/procedure-related; serious neurologic complications were rare, with one subdural hematoma-associated death reportedLamer 2019 (92)
SCSIntractable spine and/or limb painImplanted SCS vs MT; includes conventional vs high-frequency SCS comparisons (RCTs; min follow-up ≥3 months)Spinal cord pathways (dorsal columns/dorsal horn circuits)Systematic review of RCTs + meta-analysisOpioid/pain medication use (opioid reduction/cessation; Medication Quantification Scale (MQS); morphine equivalent dosage (MED)Opioid reduction ↑ (OR 8.60, 95% CI 1.93–38.30); MQS ↓ (WMD −1.97, 95% CI −3.67 to −0.27). HF vs conventional SCS: opioid reduction not statistically significant (NS) (OR 1.43, 95% CI 0.74–2.78); MED change NSAEs variably reported; mostly hardware/implant site pain and lead migration; rare serious neurologic events reportedPollard 2019 (224)
SCSLow back painImplanted epidural spinal cord stimulation (electrodes + IPG); trials include placebo-controlled cross-over designs and parallel trials adding SCS to medical managementSpinal cord pathways (dorsal columns/dorsal horn circuits)Cochrane reviewPain intensity, function, quality of life (QoL), AEs (incl. serious AEs (SAEs), need for revision surgery)6 mo vs placebo: SCS probably does not improve pain/function/QoL (moderate certainty); ≥12 mo mean pain not evaluated. SCS + MT vs MT: pain/QoL uncertain (very low certainty); function/opioid use may slightly improve (low certainty)Surgical/device AEs (infection, lead migration; occasional SAEs. Revision surgery reported (up to ∼31% at 24 mo in one trial); AE reporting inconsistent across studiesTraeger 2023 (118)
DRGComplex regional pain syndrome (CRPS) I/II; causalgia (lower extremity focal/dermatomal pain)Implanted DRG stimulation vs implanted conventional SCSDorsal root ganglion → dorsal horn circuitsImplanted DRG stimulation vs implanted conventional SCS (randomized comparative effectiveness trial)Treatment success (composite incl. ≥ 50% VAS reduction + no stimulation-related neurologic deficit), VAS pain intensity; paresthesia specificity/postural variationTreatment success higher with DRG vs SCS at 3 mo: 81.2% vs 55.7% (P < 0.001); maintained at 12 mo: 74.2% vs 53.0%; less postural variation in paresthesia and less extraneous stimulation in non-painful areas with DRGDevice-related and SAEs not different between groups; typical implant/device risks (e.g., infection, lead migration/lead issues, pocket pain) reportedDeer 2017 (106)
MCSRefractory chronic neuropathic painImplanted epidural motor cortex stimulation with randomized active vs sham crossover comparisonM1Single center RCTPain intensity [numerical rating scale (NRS)]; responder statusPain reduction during active stimulation was variable; long-term responders were observed in a subset of patients (∼39% long-term responders), but overall efficacy was heterogeneousInvasive neurosurgical/device-related risks, including infection, seizures, and hardware complications; no major unexpected safety signal in this small trialHamani 2021 (52)
VNS (implantable/invasive)Chronic pain (mixed conditions)Implanted cervical VNSCervical vagus nerveNarrative review; invasive-VNS evidence subsetPain intensity/pain reliefLimited and heterogeneous pain-specific clinical evidence; possible benefit reported in selected conditions, but no firm efficacy conclusionsImplant-related AEs possibleShao 2023 (225)
VNS (implantable/invasive)Treatment-resistant fibromyalgiaImplanted cervical VNSCervical vagus nerveProspective open-label Phase I/II proof-of-concept trialPain intensity; patient global improvement; physical function; widespread pain and tender-point criteriaPreliminary improvement was reported in a subset, with additional responses during follow-up; interpretation is limited by the small, uncontrolled designImplantation-, device-, and stimulation-related AEs occurred; one device required revision and one was later explanted for lack of perceived benefitLange 2011 (130)
aVNSChronic pain (mixed conditions)Auricular VNS, transcutaneous or percutaneous, vs sham/controlAuricular branch of the vagus nerveSystematic review and meta-analysisPain intensity/analgesic useSignificant reduction in chronic pain intensity vs. sham/control; greater effect with percutaneous than transcutaneous aVNSVery well tolerated; mainly mild local AEsDuff 2024 (132)a
n-VNSMigraineNoninvasive VNS, including cervical (n-cVNS) and auricular (n-aVNS) approaches, vs sham/controlCervical vagus nerve/auricular branch of the vagus nerveSystematic review and meta-analysis of RCTsMonthly migraine/headache days, pain-free rate within 2 h, ≥50% responder rate, headache intensity, AEsn-cVNS: ↑ ≥ 50% responder rate (OR 1.64, 95% CI 1.10–2.47); no significant reduction in migraine days or headache days.n-aVNS: ↓ migraine days (mean difference (MD) −1.8, 95% CI −3.34 to −0.26) and ↓ headache intensity (standardized MD (SMD) −0.7, 95% CI −1.23 to −0.17)n-cVNS was safe and well tolerated; no significant increase in AEs vs shamSong 2023 (226)
n-VNSCluster headachebNoninvasive VNS, mainly cervical n-VNS, vs sham/controlCervical vagus nerveSystematic reviewAttack frequency, pain intensity, responder rates, AEsModerate-to-high-quality evidence suggested benefit in reducing cluster headache frequency and intensity; benefit was clearer in episodic than chronic cluster headache, and heterogeneity prevented meta-analysisGenerally safe and well tolerated in noninvasive studiesFernandez-Hernando 2023 (227)
tDCSChronic pain (mixed conditions)tDCS vs shamM1 (most studies)/other cortical targetsCochrane systematic review of sham-controlled randomized and quasi-randomized trialsPain intensity, disability, QoL, AEsShort-term pain reduction vs sham: Standardized Mean Difference (SMD) −0.43 (95% CI −0.63 to −0.22), corresponding to ∼0.82 points on a 0–10 scale or ∼17% reduction; no clear disability benefit; long-term effect not supported. Evidence quality very low, with heterogeneity and possible small-study biasMostly minor/transient AEs (e.g., headache, scalp irritation, tingling, redness); no major lasting safety signal reportedO’Connell 2018 (153)
tDCSNonspecific chronic low back paintDCS (multiple sessions) vs shamM1Systematic review and meta-analysis of RCTsPain intensity, disability, AEsNo significant post-treatment benefit for pain (SMD 0.378, 95% CI −0.264 to 1.020; P = 0.249) or disability (SMD 0.143, 95% CI −0.214 to 0.499; P = 0.434); evidence does not support clinical use based on available dataNo significant AEs reportedAlwardat 2020 (228)
tDCSPainful diabetic polyneuropathyAnodal tDCS over left M1 vs sham; 2 mA, 20 min, 5 consecutive daysM1Randomized, sham-controlled trialVAS pain intensity, Clinical Global Impression, pain thresholdSignificant pain reduction vs sham, sustained at 2 and 4 weeksNo major safety signal reportedKim 2013 (161)
rTMSChronic pain (mixed conditions)rTMS vs shamM1 (most studied). Some studies targeting prefrontal cortexCochrane systematic review of sham-controlled randomized and quasi-randomized trialsPain intensity, disability, QoL, AEsSmall short-term effect overall: SMD −0.22 (95% CI −0.29 to −0.16), corresponding to ∼0.40 points on a 0–10 scale; high-frequency single-dose M1 stimulation showed a somewhat larger short-term effect but still did not clearly meet clinical importance thresholds; no clear disability benefitMostly minor/transient AEs; two seizures reported with active rTMS across included studies; AE reporting inconsistentO'Connell 2018 (153)
rTMSNeuropathic painrTMS vs shamM1 (most studied)Systematic review and meta-analysis of RCTsPain intensityrTMS was better than sham in reducing pain; significant analgesic effects were associated with M1 stimulation and high-frequency rTMS (≥5 Hz); no evident difference between single- and multi-session protocolsNo significant difference in AEs vs. control; reported adverse effects were generally mild/transientJiang 2022 (229)
rTMSFibromyalgia10-Hz rTMS vs shamM1 and DLPFCSystematic review and meta-analysis of RCTsPain intensity, QoL, depression10-Hz rTMS reduced pain and improved QoL; subgroup analysis found no significant difference between M1 and DLPFC for pain, although M1 showed a nonsignificant trend toward greater analgesiaNo pooled AE analysis reportedZhu 2023 (230)
Deep TMSCentral neuropathic painDeep rTMS (H-coil) vs sham; superficial rTMS comparatorM1Randomized sham-controlled multicenter crossover trialPain intensityDeep and superficial M1 rTMS both produced analgesic effects of similar magnitude; deep-rTMS effects appeared later but tended to last longer on some secondary outcomes.Mostly mild-to-moderate AEs (mainly stimulation-site pain and headache); no treatment-related SAEs reportedBouhassira 2024 (231)
TBSChronic pain (mixed conditions; mainly neuropathic pain)Theta burst stimulation alone or as priming before HF-rTMSPrimarily M1Systematic reviewPain intensity/pain reliefSome studies reported pain relief, particularly with iTBS of M1 alone or as priming before HF-rTMS, but evidence remains limited and insufficient for firm conclusionsNot systematically reported in review summaryMussigmann 2025 (232)a
tACSChronic pain (mixed conditions)tACS vs shamMixed targets (M1, bilateral frontal lobe, occipital lobe)Systematic review of RCTsPain intensityInsufficient evidence for a conclusive effect overall; findings were mixed across fibromyalgia, low back pain, and migraineSafety not established through pooled analysis; evidence base remains limitedChang 2023 (233)
CESChronic pain (mixed conditions)CES vs sham/usual careCranial applicationSystematic review of RCTsPain intensity, function, AEsEvidence was insufficient/inconclusive for clinically important pain benefit across chronic pain conditionsNo SAEs reported; minor symptoms occurred, but AEs reporting was limited/inconsistentShekelle 2018 (173)
CESFibromyalgiaCES vs sham vs usual careEarlobe electrodesRCTPain intensity, fatigue, sleep disturbance, functional statusCES was associated with greater decreases in pain and sleep disturbance, with improved functional status vs. sham and usual care over time; fatigue also trended to improvementVery few AEs reported; no blood-pressure safety signal was observedTaylor 2013 (178)
TENSChronic pain (mixed conditions)TENS vs sham/placeboSurface electrodes at the site of pain or over nearby peripheral nerve bundlesSystematic review and meta-analysis of RCTsPain intensity during or immediately after TENSTENS was associated with lower pain intensity during or immediately after treatment vs. placebo; subgroup analyses did not identify pain duration (acute vs chronic) or diagnosis as effect modifiersNo SAEs directly attributable to TENS were reported; AEs were generally mild/infrequent and not significantly different from comparatorsJohnson 2022 (234)a
TENSFibromyalgiaTENS vs sham/placeboSurface electrodes over painful areasCochrane systematic review of RCTsPain intensity, fatigue, function, QoL, AEsVery low-certainty evidence; unable to determine whether TENS improves pain vs. shamNo SAEs clearly attributable; AE reporting limited/inconsistentJohnson 2017 (235)
TENSFibromyalgiaTENS vs sham, no intervention, or active comparators (e.g., exercise, physiotherapy modalities, pharmacologic therapy)Surface electrodes over painful areasSystematic review and meta-analysis of controlled clinical trialsPain intensity, disability, QoLTENS was associated with ↓ pain (SMD −0.61, 95% CI −1.00 to −0.16), ↓ disability (SMD −0.27, 95% CI −0.41 to −0.12), and ↑ physical QoL (SMD 0.26, 95% CI 0.08 to 0.44)AEs not systematically reported; no pooled safety analysisGarcia-Lopez 2024 (236)
PNSChronic pain (mixed conditions)PNS vs comparator/sham/usual carePeripheral nervesSystematic reviewPain relief, functional improvement, AEsFor chronic pain, evidence was strongest for refractory peripheral nerve injury (level II), with lower-level evidence for some other indicationsSafety generally acceptable, but AEs varied by device, target, and studyHelm 2021 (203)
PNSHemiplegic shoulder pain after strokeSingle-lead percutaneous PNS vs usual carePeripheral nerve target in the shoulder/deltoid regionSingle center RCTPain intensity, pain interference, QoL, AEsGreater reduction in pain vs. usual care, maintained at least 12 weeks after treatmentNo serious infections; lead dislodgement, retained fragments, pruritus, and transient implant-site pain were reportedWilson 2014 (237)
PNFSLocalized chronic intractable back painRandomized crossover comparison of PNFS stimulation conditions; follow-up in implanted respondersSubcutaneous painful field of the backRCTPain intensity, disability, patient satisfaction, AEsPNFS improved pain during the randomized crossover phase, and responders who proceeded to permanent implantation maintained significant pain reduction through 52 weeksGenerally well tolerated; device/procedure-related AEs were reportedMcRoberts 2013 (238)
SCS + PNSBrachial plexopathy/focal upper-extremity neuropathic painCombined SCS with PNSCervical spinal cord + radial nerve (selected peripheral target)Case reportPain intensity/medication use/functional statusAfter loss of benefit from prior SCS alone, addition of radial-nerve PNS was associated with disappearance of background pain, residual breakthrough pain at NRS 2–3/10, reduced analgesic use, and maintained benefit at 6 months; evidence is limited to a single caseNo procedural complication was reported in this case; AE characterization is limited by single-case evidenceChoi 2016 (239)
SCS + PNFSChronic low back and leg painCombined SCS with PNFSDorsal columns + painful subcutaneous fieldCase seriesOverall pain control/pain coverageMost patients reported better overall pain control and improved coverage with the combination than with either modality alone; in some cases, PNFS was added after SCS alone did not adequately control low back painNo trial-period complications were reported (including no infections or dislodged/pulled wires); broader implant-related risks remain relevant, but formal AE characterization was limited in this small case seriesBernstein 2008 (212)

For each modality–indication pair, we prioritized higher-level evidence syntheses (Cochrane reviews, systematic reviews, and meta-analyses). When such evidence was limited, inconsistent, or unavailable, we selected representative sham-controlled randomized trials or other illustrative prospective studies, emphasizing studies with clearly described stimulation parameters and quantitative pain outcomes. This table is intended to summarize representative evidence rather than provide an exhaustive systematic inventory.

The cited study includes chronic, acute, and/or experimental pain populations; this table emphasizes the findings most relevant to chronic pain.

Includes episodic and chronic cluster headache populations.

To support this broad, cross-modality review, targeted searches were conducted using bibliographic and regulatory sources, including PubMed/MEDLINE, Cochrane reviews, and publicly available FDA documents. Searches combined terms related to pain management, with emphasis on chronic pain and selected acute or episodic pain/headache indications, with modality-specific terms spanning peripheral nerve, spinal cord, dorsal root ganglion, vagal/autonomic, cranial/transcranial, cortical, and deep brain neuromodulation approaches, including implanted and noninvasive modalities where applicable.

Historical, mechanistic, technical, clinical, and regulatory sources were used to contextualize the development, rationale, stimulation paradigms, and current clinical positioning of each modality. Primary sources were prioritized for foundational concepts, historical milestones, and specific clinical or experimental findings. Reviews, guidelines, evidence syntheses, and regulatory sources were used to support broader summaries of clinical evidence, regulatory status, mechanistic frameworks, evidence strength, and limitations across modalities. Clinical evidence discussion prioritized systematic reviews, meta-analyses, Cochrane reviews, randomized controlled trials, and selected clinical studies relevant to pain, emphasizing pain-related outcomes, safety, durability, and limitations. Because the goal was to provide a narrative review rather than a systematic review, searches were not intended to be exhaustive, and no formal risk-of-bias or evidence-grading framework was applied.

2 Implanted neuromodulation approaches

2.1 MCS: historical development of motor cortex stimulation

MCS, typically delivered as epidural brain stimulation (EBS) over M1, involves epidural placement of electrodes over the dura covering M1 to modulate downstream pain networks. Although MCS was formally introduced clinically in 1991 (39), the concept emerged earlier from experimental observations and from efforts to identify cortical targets that might provide analgesia when other central stimulation approaches showed limited success (40). Tsubokawa et al. first reported motor cortex stimulation for pain control in patients with central pain in 1991 (39). In 1993, Meyerson et al. (41) described the use of MCS in different forms of neuropathic pain. In 1995, Migita et al. (42) and Peyron et al. (43) independently reported further evidence of MCS efficacy in central pain studies, with Migita also suggesting that response to TMS over M1 might help predict response to implanted MCS. Over time, implantation and targeting strategies evolved from early epidural approaches toward more refined localization using neuronavigation, intraoperative electrophysiology, and, in some centers, functional imaging (44, 45). Programming, however, remained largely empirical, with stimulation parameters and electrode-contact configurations adjusted according to individual pain response (40, 46). By 2020, a systematic review and meta-analysis for orofacial pain noted that MCS had been performed in approximately 700 cases worldwide for a variety of refractory neuropathic pain syndromes (47).

Mechanisms of analgesia from MCS remain incompletely established, but converging electrophysiological and functional imaging findings support a distributed network-level effect rather than a purely local cortical action. MCS appears to engage thalamic circuitry, together with slower, longer-lasting modulation of medial pain-network regions, including the anterior cingulate and orbitofrontal cortices, as well as midbrain structures such as the PAG (38, 48, 49). Proposed mechanisms include altered affective appraisal of pain through cingulate-orbitofrontal modulation, recruitment of descending inhibitory pathways, and possible involvement of endogenous opioid systems (38, 48).

Clinical evidence for MCS remains largely based on case series and observational cohorts, with relatively few controlled trials and substantial heterogeneity in patient selection and outcome reporting. Analgesic benefit has been reported in selected patients with refractory neuropathic pain, but response rates and durability vary across studies, and overall confidence is limited by small samples, inconsistent follow-up, and limited sham-controlled evidence (47, 50–52).

Stimulation has been delivered using several epidural electrode designs, most commonly 4-contact paddle electrodes, as described in technical and review literature on MCS, and, in some reports, newer 8-contact leads developed specifically for this application (40, 53). Reported programming approaches include monopolar or bipolar/anode-cathode configurations, with contact assignment and amplitude adjusted according to clinical response and tolerability. Published stimulation parameters vary widely, with reported ranges of approximately 0.5–10 V, 5–130 Hz, and 60–450 µs, underscoring the lack of a standardized programming paradigm across studies (40, 46). Daily duration and overall stimulation exposure are not reported consistently; when described, stimulation is often delivered in cycling mode rather than continuously, with on-times ranging from 10 min to 3 h and off-times from 15 min to 6 h (46). Overall, the evolution of MCS reflects a broader challenge in neuromodulation, in which the ability to influence cortical and subcortical networks has not consistently translated into predictable or durable clinical benefit partly because dosing parameters and programming remain heterogeneous (40). MCS is therefore generally reserved as a specialized neurosurgical option for carefully selected patients with refractory neuropathic pain, with broader adoption limited by the scarcity of high-quality controlled evidence (54, 55).

2.2 DBS: early intracranial analgesia and evolving targets

DBS involves the direct implantation of stimulating electrodes in selected brain targets to modulate pain processing and has been explored for refractory chronic pain for several decades. Early DBS technology emerged through adaptation of implantable cardiac pacing systems, with Medtronic playing a central role in translating pacemaker-derived neurostimulation hardware into chronic brain stimulation platforms (56). Temporary intracranial stimulation relevant to pain had already been explored in the 1950s (57–60), and chronic implanted DBS approaches for pain were reported in the 1970s (11–13, 61), spurred in part by rodent microstimulation experiments in the late 1960s (10). Initial studies focused on treating intractable pain secondary to cortical injury, anesthesia dolorosa, post-cancer pain, and diabetic neuropathic pain via direct stimulation of the internal capsule (IC), sensory thalamus, or periventricular and periaqueductal gray matter (PVG/PAG) (11, 12, 62–65). Early electrodes were mainly custom-made, featuring a diverse range of materials and dimensions, including's Heath's stainless steel or silver depth probes measuring up to ∼2.0–3.0 mm in diameter; Mazars's fine gold/copper Teflon-insulated wires at ∼0.5 mm in diameter; and Hosobuchi's custom platinum-iridium cylindrical contacts measuring 0.5 mm in diameter and 0.5 mm in length [see (66) for a review of electrode characteristics]. Across early pain-DBS series, stimulation parameters varied by target and center, with frequencies ranging roughly from 2 to 100 Hz, pulse widths from about 0.1 to 0.8 ms, and amplitudes commonly reported in the 0.5–8 V range; historical summaries suggest that PVG/PAG stimulation tended to use lower frequencies (for example, around 25–50 Hz), whereas sensory thalamic stimulation was often reported at 50–100 Hz (66).

Early custom pain-DBS systems were later replaced by commercial Medtronic platforms, initially including radio-frequency systems with transcutaneous power transfer and, in later chronic pain trials, first-generation and subsequent Medtronic leads (56, 67). Later Medtronic DBS leads adopted a standardized quadripolar geometry with a diameter of approximately 1.27 mm, four 1.5-mm-long contacts, and model-dependent edge-to-edge electrode spacing: 1.5 mm for the 3387 and 0.5 mm for the 3389 (68, 69). During this commercial expansion of DBS in the 1990s and 2000s, implanted pulse generators were largely constant-voltage systems. Typical therapeutic programming used amplitudes of about 1–3.5 V, pulse widths of 60–210 μs, and high-frequency stimulation commonly around 130 Hz and extending to 185 Hz; battery longevity depended strongly on the selected stimulation parameters and device circuitry. Because these systems were voltage-controlled, changes in electrode-tissue impedance could alter the actual current delivered and the resulting extent of neural activation (70–73).

Beginning in the mid-2010s, DBS hardware evolved from conventional ring-contact electrodes toward directional segmented leads that enabled current steering. Early commercial directional systems included 8-contact leads with segmented middle levels that could be independently activated to shape the stimulation field more selectively than traditional omnidirectional leads (70, 74). Although this development was first established in the broader DBS field, directional leads have also been used in selected chronic neuropathic pain applications, particularly sensory thalamic DBS (75–77). Boston Scientific's Vercise platform was among the earliest commercial DBS systems to implement multiple independent current control (MICC) (78), a constant-current architecture that allows independent current distribution across contacts, supports more flexible stimulation-field shaping, and can reduce impedance-related fluctuations in delivered stimulation compared with voltage-controlled systems (73). More recent systems have extended this trend to higher-contact-count designs, including 16-contact directional leads, further increasing programming flexibility and spatial selectivity (78, 79). Modern platforms also offer broad programming ranges, with pulse widths reaching up to 450 μs in some systems (70). In parallel, sensing-enabled and biomarker-driven neuromodulation studies have strengthened the rationale for adaptive DBS in chronic pain, but this remains investigational rather than an established clinical standard in pain DBS (80, 81).

Early patient investigations suggested that intermittent rather than sustained stimulation could be more effective, as continuous stimulation was associated with waning efficacy and possible tolerance to narcotic medications (12). Subsequent clinical work shifted toward evaluating long-term efficacy across different pain etiologies and anatomical targets. A meta-analysis of studies published between 1977 and 1997 found that long-term outcomes depended strongly on both pain type and stimulation target: nociceptive pain showed better long-term success than deafferentation pain (63% vs. 47%), and the highest success rates were reported with PVG/PAG stimulation alone (79%) or combined PVG/PAG plus sensory thalamus/internal capsule stimulation (87%) (82). Sensory thalamic targets were used particularly for neuropathic pain, whereas PVG/PAG stimulation was favored in nociceptive pain and linked to endogenous opioid-mediated mechanisms (12, 64, 65, 82). Despite these refinements, durability remained a major limitation, as some patients lost benefit over time and the pivotal Medtronic multicenter pain trials failed to meet prespecified efficacy thresholds. Specifically, the Model 3380 study enrolled 196 patients and the Model 3387 study enrolled 50 patients, but neither achieved the criterion of at least 50% pain relief in half of implanted patients at 1 year (67). Thus, early enthusiasm for DBS in chronic pain was limited by inconsistent long-term outcomes and failure to meet efficacy thresholds in multicenter trials. The lack of FDA-approved DBS indications for chronic pain, together with limited and region-specific European use, underscores a recurring pattern in neuromodulation in which a strong mechanistic rationale does not consistently translate into durable clinical benefit. As a result, DBS remains an off-label or investigational option for chronic pain in most settings, although interest has resurged with recent sensing-enabled and adaptive approaches (80, 81).

Overall, the DBS-for-pain evidence base remains heterogeneous and is still dominated by small case series and observational cohorts spanning diverse pain etiologies and targets, with relatively few modern controlled trials (83). Structured reviews of the multicenter trial experience and subsequent evidence syntheses highlight target- and indication-dependent variability in response and durability, and note limitations related to small samples and inconsistent outcome definitions and follow-up (67, 84). DBS is nevertheless used in highly selected cases, including in post-stroke pain, neuropathy, and pain refractory to prior SCS.

Common stimulation targets include the PVG/PAG, IC, anterior cingulate cortex (ACC), and the ventral posterolateral nucleus and ventral posteromedial nucleus (VPL/VPM), with stimulation delivered using commercial DBS hardware such as Medtronic 3387/3389 leads paired with compatible Medtronic neurostimulators, Abbott Infinity systems, and Boston Scientific Vercise systems with Cartesia directional leads, although stimulation settings in pain DBS remain highly variable across targets and studies.

DBS analgesia is generally considered target-dependent, engaging different components of the pain system (84, 85). Even when initial benefit is achieved, long-term durability remains a major limitation despite advances in hardware and programming. PVG/PAG stimulation is thought to recruit descending pain modulatory circuits, with human data supporting endogenous opioid involvement in at least a subset of patients (e.g., naloxone-reversible effects) (12, 86), although non-opioid and mixed mechanisms have also been reported (87). Sensory thalamic targets (VPL/VPM) are proposed to modulate ascending nociceptive transmission and sensory encoding (84, 85), whereas ACC, particularly dorsal ACC (dACC), stimulation is framed as reducing the affective–motivational burden of pain by modulating limbic–cognitive control networks (88, 89). Across targets, mechanisms remain debated and likely reflect network-level effects rather than a single pathway. Furthermore, although outside the scope of this article, DBS is moving towards closed-loop and personalized dosing and targeting for pain treatment, see (90) for details.

2.3 SCS: evolution of dorsal column stimulation and modern waveforms

The evolution of SCS mirrors a broader pattern in neuromodulation, where early physiological models supported rapid clinical adoption, followed by increasing recognition of heterogeneous responses and more complex, network-level mechanisms.

SCS, first introduced in 1967 under the term dorsal column stimulation (91), has evolved considerably as a treatment for intractable chronic pain (92). Its early clinical rationale was closely tied to the gate control theory proposed by Melzack and Wall, which held that activation of large-diameter, non-nociceptive afferents could suppress nociceptive transmission at the dorsal horn (15). After its initial clinical introduction, SCS was progressively formalized through commercial and regulatory development from the 1970s through the early 1990s (93), while parallel technological advances included percutaneous trial stimulation before permanent implantation, adoption of fully implantable pulse generators (IPGs), and development of multichannel systems that expanded programming flexibility and paresthesia targeting (93–96). Later advances in SCS have led to the development of high-frequency (HF) SCS and burst SCS. High-frequency SCS (10-kHz SCS, often referred to as HF10) was developed to reduce or avoid paresthesia associated with traditional SCS by applying a waveform at 10,000 Hz at a subthreshold level (97, 98). Burst SCS delivers stimulation in packets of pulses, classically five pulses per burst, at reduced amplitudes to achieve subthreshold stimulation with little to no paresthesia while maintaining analgesic benefit (99–101).

SCS is delivered by placing electrodes in the epidural space to modulate pain signaling, historically often through paresthesia-based stimulation (102). Temporary percutaneous stimulation before permanent implantation was introduced early in the development of SCS (94), and in current practice patients typically undergo a trial with temporary epidural leads connected to an external pulse generator to assess pain relief and tolerability before placement of a permanent subcutaneous pulse generator (103, 104). If the trial is successful, a permanent subcutaneous pulse generator is implanted to deliver long-term therapy (104). Pulse frequencies may range from approximately 2 to 1,200 Hz, with conventional tonic stimulation frequencies typically in the 40–60 Hz range (104). Pulse magnitudes are patient-specific and are typically programmed in the mA range [commonly across a 0–20 mA device range (105); reported clinical amplitudes for paresthesia-based tonic SCS are often in the low single-digit mA range, e.g., ∼4–9 mA (106)].

Although SCS was initially framed through the gate control theory, contemporary evidence suggests that analgesia likely reflects a combination of segmental spinal effects and supraspinal network modulation, including altered dorsal horn excitability, recruitment of large-diameter afferent fibers, and engagement of descending inhibitory pathways; the relative contribution of these mechanisms may differ across tonic, burst, and high-frequency paradigms (107–111).

Clinically, SCS has been used across selected neuropathic and radicular pain indications, including failed back surgery syndrome, complex regional pain syndrome (CRPS), and painful diabetic neuropathy (112–114). FDA-authorized SCS indications are device-specific, with selected labeling including chronic intractable pain of the trunk and/or limbs and conditions such as failed back surgery syndrome, CRPS, radicular pain, and painful diabetic neuropathy (115, 116). Interpretation of the SCS evidence is also influenced by the common use of trial stimulation before permanent implantation, which may affect patient selection and the composition of implanted cohorts (103). Systematic reviews and network meta-analyses generally support SCS as being associated with improved pain outcomes vs. conventional medical management in selected chronic neuropathic pain populations, although certainty varies by indication, trial design, and outcome assessed (117). In contrast, for chronic low back pain populations studied with placebo/sham comparators, some evidence syntheses have reached more skeptical conclusions, underscoring that comparator choice, patient selection, and follow-up duration can materially influence inferred efficacy (118). SCS has also been reported in post-amputation pain, including phantom limb pain, but the evidence remains limited to small heterogeneous series and a recent scoping review suggesting possible benefit in a subset of patients (119, 120). Cross-study interpretation is complicated by two layers of heterogeneity: tonic, burst, and high-frequency SCS paradigms differ in waveform design, paresthesia profile, and inferred mechanism, and the studies evaluating them also vary in comparator design.

2.4 Dorsal root ganglion (DRG) stimulation: targeted stimulation for focal pain syndromes

DRG stimulation emerged as a more anatomically targeted neuromodulation approach within the broader SCS family, designed to improve coverage of focal pain distributions that may be difficult to treat with conventional dorsal column stimulation (121, 122). By placing leads near the dorsal root ganglion, DRG stimulation enables more selective modulation of sensory signaling at the level of the affected dermatome and has been particularly applied in conditions such as CRPS and focal causalgia (106, 121). Because the dorsal root ganglion contains the cell bodies of primary sensory neurons and has been implicated in pathological sensory signaling in chronic pain states, it represents a biologically relevant target for neuromodulation (121). This anatomical specificity may be particularly advantageous in focal neuropathic pain confined to discrete dermatomal or localized regions (106, 123). Compared with conventional SCS, DRG stimulation may offer more stable paresthesia coverage in anatomically discrete pain regions, although programming remains individualized and evidence varies by indication (106, 122, 123). In the United States, DRG stimulation received FDA approval in 2016 for neuropathic pain associated with CRPS and causalgia of the lower extremity (124, 125), and the strongest comparative clinical evidence remains concentrated in these focal neuropathic pain populations (106). Overall, DRG stimulation represents the move in the neuromodulation field toward anatomically precise targeting. Nevertheless, the variability in clinical response highlights that increased spatial specificity does not fully resolve the physiological puzzle of pain network modulation.

3 Vagal neuromodulation

3.1 VNS: evolution of implanted and noninvasive approaches

VNS targets vagal afferent pathways to modulate central pain networks and autonomic-neuroimmune signaling (126, 127). Although VNS was first clinically evaluated as an implanted cervical therapy for refractory epilepsy (128) and later for treatment-resistant depression (129), implanted cervical VNS has also been explored in treatment-resistant fibromyalgia (130). More recently, noninvasive VNS approaches have emerged, including cervical nVNS for headache disorders (131) and auricular VNS for acute and chronic pain conditions (132, 133). Accordingly, this subsection considers both implanted and noninvasive VNS approaches.

Clinically, VNS can be delivered invasively via an implanted cervical vagus nerve stimulator or noninvasively via transcutaneous auricular VNS (taVNS) or cervical nVNS (126, 134). Although these approaches are often grouped under the VNS umbrella, implanted cervical VNS, cervical nVNS, and taVNS differ substantially in hardware, dosing, anatomical access, and current clinical positioning (126, 134, 135). In pain medicine, the strongest regulatory and clinical support relates to cervical nVNS for headache disorders, whereas implanted VNS and transcutaneous/auricular VNS applications in non-headache chronic pain remain more exploratory and are supported by a heterogeneous evidence base (132, 134, 136).

Dosing and programming vary by device and indication. In taVNS clinical studies, commonly reported settings include ∼25 Hz stimulation with a pulse width of ∼0.5 ms, with intensity titrated to the maximum tolerated sensory level (often within the low-mA range), sometimes delivered in duty cycles for session-based use (137). For cervical nVNS used for headache indications, dosing is typically delivered as short, repeated ∼2-minute applications per treatment episode (acute use), with preventive regimens depending on the labeled indication (138, 139).

Mechanistically, VNS is thought to engage vagal afferent pathways projecting to brainstem relay nuclei, particularly the nucleus tractus solitarius, with downstream effects on networks involved in ascending pain processing and descending inhibitory control. VNS has also been linked to autonomic and neuroimmune pathways, although the relative contribution of these mechanisms may differ across implanted cervical, noninvasive cervical, and auricular approaches (127, 133). A recent randomized, sham-controlled trial in rheumatoid arthritis further supports the clinical relevance of vagus-mediated neuroimmune modulation, showing that implanted cervical VNS can modulate inflammatory disease activity in humans. These findings support target engagement of the inflammatory reflex, although they do not directly establish analgesic efficacy in chronic pain (140).

Evidence for VNS in pain is indication-dependent. nVNS has regulatory clearance for certain headache indications, including migraine and cluster headache (138), and has also been studied in other chronic pain conditions with heterogeneous results. A recent systematic review and meta-analysis of transcutaneous VNS reported measurable pain reduction across some chronic pain conditions, but emphasizes variability in populations, stimulation parameters, comparators, and outcomes (136). Overall, the development of VNS embodies the expansion of neuromodulation beyond traditional somatosensory networks. Its heterogeneous outcomes underscore the challenges of translating autonomic/neuroimmunological modulation into consistent analgesic effects in the context of different stimulation sites (auricular vs. cervical), dosing schedules, and comparator conditions. Evidence is strongest for labeled headache indications, whereas magnitude and durability of benefit in non-headache chronic pain conditions remain uncertain and appear sensitive to protocol and population differences (134, 136, 138, 139).

4 Noninvasive central/cranial neuromodulation

4.1 TMS: from noninvasive cortical stimulation to analgesic protocols

TMS was developed in the mid-1980s as a noninvasive method for stimulating the human cortex (14) through the intact scalp and was later extended from single-pulse neurophysiologic applications to repetitive and patterned therapeutic protocols (141, 142). TMS uses electromagnetic coils to generate brief, rapidly changing magnetic fields that induce electric currents in neural tissue, thereby activating cortical neurons and modulating neural excitability (2, 14, 143). TMS can produce pulsed fields of up to 4 Tesla, but commonly near 2 T, with pulse durations on the order of approximately a millisecond for single-pulse stimulators (with shorter rise times) and approximately a quarter of a millisecond duration for rapid stimulators (14, 144, 145). Stimulation effects can be inhibitory or excitatory depending on the frequency and pattern of stimulation and can persist beyond the duration of stimulation (143). The most widely used therapeutic form, rTMS, is typically delivered with a figure-of-eight coil and primarily reaches superficial cortical targets (typically 2–3 cm in depth). Deep TMS, which is postulated to reach deeper structures than conventional rTMS, albeit with reduced focality, can be delivered with different coils, such as double-cone, Halo, and H-coils (146). Finally, theta-burst stimulation (TBS) is a patterned form of rTMS in which short high-frequency bursts (classically 3 pulses at 50 Hz) are repeated at a theta rate (classically 5 Hz) and delivered in continuous (cTBS) or intermittent (iTBS) patterns (147). In M1 physiology studies, cTBS is often associated with reduced and iTBS with increased corticospinal excitability, although direction and duration can vary with protocol and context (147). TBS over M1 has also been explored in pain indications within the broader evidence base for therapeutic rTMS (141).

Both rTMS and deep TMS have been investigated for pain modulation, with the bulk of research focused on rTMS. The most studied target of stimulation is the motor cortex, but other targets, such as the dorsolateral prefrontal cortex (DLPFC) or the parietal cortex, have also been explored (141, 148–150). Neuropathic pain syndromes have been shown to be among the conditions most responsive to TMS (142, 151). In this patient population, stimulation applied to the contralateral side of pain has been shown to induce analgesic effects; different therapeutic protocols have been explored with various stimulation parameters, such as frequency (e.g., 10 Hz or 20 Hz); intensity [expressed as a percentage of the resting motor threshold (RMT)]; number of pulses (1,500–3,000); and number of sessions [see (141, 142) for a more complete list of stimulation parameters]. A typical protocol used by many laboratories consists of 10 consecutive weekday sessions followed by maintenance sessions at 1 week, 2 weeks apart, and a month apart (142). All of the above parameters might influence the magnitude and duration of pain relief (152).

The mechanisms underlying the analgesic effect of TMS remain incompletely established, but TMS is thought to modulate the activity of cortical and subcortical brain structures that are involved in pain processing (148). While TMS is considered a safe and well-tolerated form of brain stimulation, efficacy results have been mixed (153). A recent Cochrane review on rTMS applied to M1 showed that the analgesic effects of neither single-session nor multi-session protocols are likely to be clinically significant or improve disability (153). The mixed efficacy observed with TMS reflects a recurring challenge in neuromodulation, where heterogeneity among studies remains high and subsequently the ability to modulate neural circuits does not consistently translate into conclusive results pertaining clinical efficacy, optimal target site, and optimal dosing (152).

4.2 Transcranial direct current stimulation (tDCS): from cortical polarization to analgesic montages

Although weak transcranial direct current stimulation had been explored in human studies in the 1960s and 1970s, contemporary tDCS was revitalized in the early 2000s after reproducible demonstrations of polarity-dependent modulation of cortical excitability and has since been increasingly investigated as a noninvasive approach for pain modulation (154, 155).

tDCS uses electrodes placed on the scalp to deliver low-intensity direct current to underlying cortical targets, thereby modulating cortical excitability and influencing pain-related networks. tDCS typically delivers 1–2 mA of constant direct current through electrodes of ∼25–35 cm2 for 20 min/session (156), increasing or decreasing excitability of neural targets depending on the relative electrode orientation (i.e., field polarity relative to neural targets) (154). When stimulation is provided over multiple sessions, more persistent network effects can be induced; for chronic pain therapy, stimulation is typically delivered in repeated 20-min sessions, often over 5–10 sessions.

tDCS has been used to target different conditions by using different montages. There are two main approaches for tDCS modulation of chronic pain, either placing the electrodes over M1, thereby modulating plasticity of motor circuits related to pain (see MCS above), or over the DLPFC to impact cognitive–affective control of pain (e.g., attentional control, reappraisal, catastrophizing) (157, 158). These montages reflect two complementary therapeutic frameworks: M1 stimulation is generally interpreted as engaging sensorimotor and descending modulatory pathways, whereas DLPFC stimulation is used to influence cognitive–affective dimensions of pain. In both cases, analgesic effects are thought to arise from modulation of distributed pain-related networks rather than direct focal suppression of nociceptive input (157, 158). These network-level effects are thought to involve distributed cortico-subcortical networks, including frontostriatal and descending modulatory pathways, with putative interactions with reward- and brainstem-modulatory nodes (e.g., the nucleus accumbens and PAG). Sham-controlled trials have reported short-term analgesic effects of anodal M1 tDCS (2 mA, 20 min, 5 consecutive days) in fibromyalgia (159, 160), central neuropathic pain after traumatic spinal cord injury (160), and painful diabetic polyneuropathy, with benefits persisting for weeks in follow-up (161). However, across indications the literature remains heterogeneous in populations, dosing, sham methods, and outcomes, and a 2018 Cochrane review concluded that “very low-quality evidence suggests that tDCS may have short-term effects on chronic pain” (153). These findings further illustrate the gap between physiologically plausible modulation of neural networks and reproducible clinical benefit, with evidence suggesting modest, short-term analgesic benefit in selected conditions, but durability and optimal montage/dose remain uncertain due to variability in protocols and outcomes (153).

4.3 Transcranial alternating current stimulation (tACS): oscillatory modulation in pain

Human experimental studies of tACS began in the late 2000s, and subsequent work established the technique as an oscillation-oriented form of transcranial electrical stimulation designed to interact with endogenous brain rhythms (162, 163). Similar to tDCS, tACS uses scalp-placed electrodes to apply weak alternating currents noninvasively to cortical targets. tACS delivers a weak (<2 mA) alternating electrical current between conventional scalp electrodes (typically ∼25–35 cm2 saline-soaked sponge pads; e.g., 5 × 5 or 5 × 7 cm) (164, 165) and aims to interact with the naturally rhythmic electrophysiologic activity of the brain, which can be detected by electroencephalography (EEG) and magnetoencephalography (MEG). tACS is thought to promote entrainment (i.e., synchronization or desynchronization) of brain oscillations to the stimulation frequency (163), and may also modulate long-range oscillatory coupling between distributed brain regions (e.g., phase-specific changes in interhemispheric functional connectivity) (166). The stimulation frequency can be fixed or matched to specific features of oscillatory activity recorded from the patient (167). As with other transcranial electrical stimulation techniques, the physiological and behavioral effects of tACS likely depend on montage, current intensity, stimulation frequency, session duration, and baseline brain state of the participant, which complicates comparison across studies (164–167). In pain-related studies, montages have typically been designed to target somatosensory or prefrontal regions, although the optimal electrode configuration for engaging pain-relevant oscillatory networks remains uncertain (167–170). Typical experimental montages include bilateral or unilateral primary somatosensory cortex or frontally oriented configurations targeting the dorsolateral prefrontal cortex, sometimes combined with extracephalic reference electrodes (165, 167). In the brain, pain has been associated with oscillations at alpha (8–13 Hz) and gamma (30–100 Hz) frequencies over somatosensory and prefrontal areas (171); these oscillations can be targeted using tACS at the same frequency to promote entrainment (163), which may in turn influence pain perception. This oscillation-based framework provides a compelling mechanistic rationale for the use of tACS in pain modulation, particularly considering evidence that pain-related alterations in alpha and gamma activity occur across somatosensory and frontal networks (171). However, whether these oscillatory signatures are causally related to clinically meaningful analgesia remains uncertain, and the therapeutic value of frequency-matched or individualized tACS protocols has yet to be established (168–170, 172).

To date, relatively few studies have investigated the use of tACS for pain modulation, with mixed results. Clinical evidence remains preliminary and consists largely of small pilot trials with heterogeneous protocols and outcomes, so effectiveness and durability are uncertain and not yet guideline-established (168–170, 172). While some studies have provided preliminary evidence that tACS at alpha frequencies delivered over somatosensory areas during one or more sessions [e.g., 10 sessions over 2 weeks in (172)] may produce analgesic effects (168, 170, 172), other studies using tACS at alpha and gamma frequencies over prefrontal and somatosensory areas have been inconclusive or shown no effect (169).

Overall, tACS provides a mechanistically appealing approach grounded in oscillatory brain dynamics, yet its clinical trajectory reflects the broader challenge of translating modulation of neural rhythms into consistent and clinically meaningful analgesia.

4.4 Cranial electrical stimulation (CES): from electrosleep to cranial electrotherapy

CES is a noninvasive neuromodulation technique that applies very low-intensity pulsed electrical currents to the head, commonly via ear-clip (earlobe) electrodes and, less commonly, scalp montages, with the aim of modulating brain networks relevant to pain and related symptoms such as sleep and mood (173). Historically, CES emerged from early 20th-century “electrosleep” approaches, which were intended to induce a sleep- or sedative state, although later investigators argued that any apparent sleep-promoting effects were more likely indirect and related to relaxation rather than true sleep induction (174). Over time, the clinical framing shifted from attempts to induce electrosleep toward broader symptomatic modulation of pain, anxiety, insomnia, and related conditions, such that modern CES is better understood as an evolution rather than a direct continuation of early electrosleep paradigms. CES gained broader clinical use in the United States in the 1960s and 1970s, making it one of the earliest low-intensity cranial electrical neuromodulation modalities to enter broader clinical use (175). CES is often described as a form of transcranial pulsed current stimulation (tPCS) and is technically distinct from tDCS/tACS in that it typically uses pulsed waveforms and can be delivered at low current intensities through infra- or supra-auricular electrode placements (176). Early electrosleep protocols generally used pulsed currents in the 30–100 Hz range (174), whereas contemporary CES devices use device-specific parameters, with commonly reported modern settings including microcurrent intensities and frequencies such as 0.5 or 100 Hz (177). Current systems provide a versatile range of output parameters, with pulse durations ranging from microseconds to milliseconds and current intensities from microamps to upwards of 1 mA. These devices typically utilize biphasic square-wave pulse forms. Proposed mechanisms remain incompletely established and are generally framed in terms of broad modulation of cortical and subcortical network activity, rather than a single established analgesic pathway (177).

CES exemplifies a longstanding gap in neuromodulation in chronic pain between early clinical technological adoption and mechanistic clarity. Systematic evidence assessments have concluded that clinical benefits are uncertain and the evidence base is heterogeneous across populations, comparators, and outcomes (173), although some individual studies in specific conditions such as fibromyalgia have reported improvements in pain and related symptoms (178, 179). Interpretation of the CES literature is further complicated by substantial variability in study design, stimulation parameters, and outcome measures, as well as by the inclusion of earlier studies conducted prior to contemporary trial standards, making it difficult to define a clear therapeutic role for CES in chronic pain management.

5 Peripheral neuromodulation

Peripheral neuromodulation includes both noninvasive surface stimulation techniques and implanted or percutaneously placed systems targeting either named peripheral nerves or broader painful fields.

5.1 Noninvasive peripheral stimulation

5.1.1 TENS: gate-control foundations and clinical Use

TENS emerged in the early 1970s, shortly after the publication of gate control theory, and became one of the earliest noninvasive electrical therapies used for pain management (15, 180, 181). TENS is delivered across the skin surface to stimulate peripheral nerves through electrode pads. Standard TENS is generally considered safe and inexpensive, typically consisting of a battery-powered hand-held device that generates pulsed electrical currents (182).

Stimulation is characterized by current amplitude, pulse width, and frequency. In clinical use, intensity is typically titrated above sensory threshold to produce a perceptible, non-painful paresthesia. Typical clinical TENS uses frequencies of ∼2–150 Hz and pulse widths of ∼50–400 μs, with sessions commonly lasting ∼20–60 min (183–185). FDA 510(k) summaries for commercial TENS devices report maximum output currents commonly in the tens to low hundreds of milliamperes, with values depending on device and load condition (186–188). The original principle of TENS derives from the gate control theory of pain, which proposes that activation of non-nociceptive afferent input can inhibit transmission of painful signals at the spinal level (15). This is commonly framed as preferential activation of large-diameter, non-nociceptive afferent fibers (182), which may inhibit nociceptive transmission at the spinal level and engage descending inhibitory systems (182). Mechanistic studies have further extended the original gate-control framework to include frequency-dependent neurochemical modulation (e.g., endogenous opioid and serotonergic signaling) and recruitment of descending inhibitory pathways that regulate spinal nociceptive transmission (182, 189–191). These mechanisms reflect convergence of small- and large-diameter sensory inputs onto spinal neurons involved in transmitting sensory information to the brain, together with modulation by descending control pathways (15, 182). Overall, TENS became an established, portable, noninvasive option whose development paralleled the evolving understanding of frequency-dependent neurochemical modulation. Its clinical efficacy, however, has remained inconsistent across pain conditions and study designs. Earlier reviews reached negative or limited conclusions, in part because of methodological limitations and insufficient data suitable for quantitative pooling (192, 193). More recently, Paley et al. conducted a descriptive analysis of 169 reviews (eight overviews, seven hybrid reviews and 154 systematic reviews with 49 meta-analyses), and they recommended TENS as a treatment option for symptomatic relief of pain (194). Their appraisal found that pain intensity was lower during or immediately after TENS compared with control interventions for acute and chronic pain (194). In perioperative settings, TENS has also been evaluated as an adjunct to conventional analgesic management, with evidence suggesting reductions in postoperative pain and analgesic consumption (195). These apparently divergent findings may reflect differences in treatment delivery, because analgesic response depends in part on achieving adequate stimulation intensity and underdosing may contribute to negative or inconsistent trial results (184, 196, 197). Overall, the strongest signals of benefit are observed during active TENS and, in some contexts, in reduced analgesic use, but confidence in broader and longer-term efficacy remains limited by frequent shortcomings in randomized clinical trials (RCTs), insufficient pooled data, and substantial variability across pain conditions and outcomes (194).

5.2 Implanted and percutaneously placed peripheral stimulation

5.2.1 Peripheral nerve stimulation (PNS): from surgical implants to percutaneous systems

PNS has been used for pain control for more than five decades, evolving from surgically implanted systems to modern percutaneous approaches. Early clinical work by Shelden and colleagues (198) reported temporary suppression of trigeminal neuralgia pain using implanted PNS electrodes (including high-frequency stimulation delivered via an implanted receiver). In 1967, Wall and Sweet described pain suppression during stimulation in a series of eight patients with chronic cutaneous pain (199). Historically, PNS required open surgical dissection to visualize the nerve and position the lead (200), and subsequent surgical modifications (e.g., interposing a fascial graft between lead and nerve) were later deemphasized due to complexity and complications (201). The modern shift toward percutaneous PNS was catalyzed in 1999 by Weiner and colleagues, who reported that percutaneous lead placement provided analgesia in occipital neuralgia (202). PNS involves placement of a stimulating lead adjacent to a specific peripheral nerve, typically percutaneously under image guidance, to deliver electrical pulses intended to reduce pain. Although mechanisms are not fully established, PNS is generally thought to reduce pain through activation of non-nociceptive afferent fibers and modulation of peripheral and spinal excitability, with possible downstream effects on central sensitization and broader pain network processing (203, 204).

The evolution of PNS reflects a broader trend toward less invasive and more anatomically targeted approaches. The persistent variability in outcomes highlights the ongoing challenge of translating peripheral modulation into consistent therapeutic effects within larger nociceptive networks. Evidence-based clinical guidelines and systematic reviews support PNS as an option for selected acute and chronic pain conditions, although the strength of evidence varies by indication and target nerve (205). However, across indications the literature remains heterogeneous in trial design, comparators, and follow-up duration, and higher-quality controlled evidence is stronger for some targets and conditions than others (205). Dosing/programming is individualized by target and system; example settings reported in clinical studies include pulse widths around ∼200 μs and frequencies around ∼100 Hz, with amplitude titrated to a comfortable sensory percept (paresthesia) (206).

5.2.2 Peripheral nerve field stimulation (PNFS): development of field-based stimulation

Whereas PNS targets a specific named peripheral nerve, PNFS evolved as a field-based strategy for regional pain distributions that are less amenable to focal nerve targeting. Field-based subcutaneous peripheral stimulation approaches were described in the early 2000s under related terms, including targeted subcutaneous stimulation and peripheral nerve field stimulation. Early reports described targeted subcutaneous stimulation and PNFS for neuropathic, abdominal, axial, and chronic low back pain; these case reports and small case series were later followed by larger observational reports that helped define PNFS as a distinct neuromodulation approach (207–211).

PNFS involves placement of leads within the subcutaneous tissues of the painful region to create a “field” of stimulation, rather than targeting a named peripheral nerve as in conventional PNS (209). It has been used both as stand-alone therapy and as an adjunct to SCS in patients with regional pain distributions (212). This field-based approach may be advantageous when a discrete peripheral nerve target cannot be identified. Although mechanisms are not fully established, PNFS is generally thought to modulate afferent input from the painful region by stimulating local nerve branches and cutaneous afferents, with downstream convergence at the spinal cord (209). It has most commonly been applied to localized or regional pain syndromes, particularly chronic axial low back pain. Stimulation is programmed in a patient-specific manner, typically titrated to comfortable paresthesia when paresthesia-based paradigms are used (209). In chronic low back pain, prospective multicenter observational data suggest improvements in pain and function, though study designs and comparators vary (213). A recent narrative review of PNFS for chronic low back pain and persistent spinal pain syndrome similarly concluded that PNFS, used alone or as an adjunct to SCS, appears to reduce pain and analgesic use and improve physical function, although high-quality long-term evidence remains limited (214). Overall, PNFS reflects a shift towards less invasive yet targeted peripheral approaches. However, its heterogeneous outcomes underscore the difficulty of achieving consistent analgesia across variable presentations.

6 Hybrid, multimodal, and dual energy approaches

Hybrid neuromodulation refers to pairing two stimulation modalities to engage complementary nodes or mechanisms within the pain system (including combinations of central and peripheral approaches), two peripheral strategies, or multimodal central stimulation. At present, hybrid approaches are better understood as an emerging design direction in pain neuromodulation than as a mature evidence class. In practice, such combinations are most often explored when a single modality provides incomplete relief or insufficient coverage of a complex pain distribution. The mechanistic rationale is that hybrid modalities may allow modulation of complementary peripheral, spinal, and supraspinal components of pain processing, although cumulative effects remain incompletely established. Clinically, most hybrid strategies remain exploratory and are typically used to address incomplete coverage or partial response, such as combining SCS with PNFS for axial low back and leg pain (212), or combining tDCS with peripheral stimulation in chronic pain (215, 216). While not classically an electrical approach, emerging central approaches may also be considered within this framework, including electrosonic stimulation, which combines tDCS with transcranial ultrasound (217, 218). Many hybrid and multimodal neuromodulation approaches recognize that single-target strategies may be insufficient to address the distributed and plastic nature of pain networks. Overall, the published literature on hybrid and multimodal approaches remains limited and heterogeneous, with variability in study design, stimulation protocols, and patient selection (215).

To complement the regulatory summaries in Tables 1–2, Table 3 synthesizes representative clinical evidence across the major electromagnetic neuromodulation modalities discussed in this review. Table 4 summarizes typical stimulation characteristics across these modalities.

Table 4. Typical stimulation characteristics of major electromagnetic neuromodulation modalities used in pain research and clinical practice.

ModalityTypical target/PlacementStimulation typeUsual treatment patternKey caveat
SCSEpidural space over dorsal columnsImplanted electrical stimulationTrial stimulation followed by permanent implant if successful; can be continuous or programmed useParameters vary widely across tonic, burst, HF10, and other paradigms
DRGLead positioned near dorsal root ganglionImplanted electrical stimulationTrial followed by implant in selected focal pain conditionsBest considered a specialized SCS variant rather than a wholly separate platform
DBSIntracranial pain-network targets (e.g., PAG/PVG, thalamus, ACC)Implanted electrical stimulationImplanted therapy, historically often intermittent daily use; modern use individualizedHighly target-dependent and heterogeneous across studies
MCSEpidural electrodes over M1Implanted electrical stimulationUsually chronic implanted therapy with individualized programmingDosing and daily use schedules are inconsistently reported
Implanted VNSCervical vagus nerveImplanted electrical stimulationChronic implanted therapyPain evidence is less established than for epilepsy/depression indications
nVNS/taVNSCervical vagus nerve externally or auricular vagal territoryTranscutaneous electrical stimulationAcute-use or repeated session-based protocols depending on indicationParameters and targets vary substantially across cervical vs auricular approaches
tDCSScalp electrodes over M1 or DLPFCWeak direct currentUsually repeated over 5–10 sessionsMontage and total dose vary across studies
rTMSSuperficial cortical targets, most commonly M1; also DLPFC or parietal cortexNoninvasive magnetic stimulationOften delivered over repeated weekday sessions, sometimes with maintenance sessionsCoil type, target, frequency, and maintenance schedule differ widely
Deep TMSDeeper and broader cortical/subcortical targets depending on coil designNoninvasive magnetic stimulationRepeated session-based protocolsPotentially greater depth with reduced focality; pain evidence remains limited
TBSUsually M1Patterned rTMS (bursts at theta rate)Short-session protocol, sometimes repeated over multiple visitsPain evidence is more limited than for conventional rTMS
tACSScalp electrodes over cortical targets, often somatosensory/prefrontal regionsWeak alternating currentSingle- or multi-session protocolsEarly-stage field with limited standardization
CESEar-clip (earlobe) electrodes, less commonly scalpLow-intensity pulsed cranial currentRepeated session-based useParameters are highly device-specific and evidence remains heterogeneous
TENSSurface electrodes over painful region or related peripheral nerve territoryTranscutaneous pulsed electrical stimulationOften 20–60 min/session, repeated as neededEffectiveness is sensitive to intensity, adherence, and timing relative to pain
PNSLead adjacent to named peripheral nerveImplanted/percutaneous electrical stimulationUsually trial or staged percutaneous/implant therapy depending on systemHighly target- and system-specific
PNFSSubcutaneous leads within painful fieldField-based electrical stimulationChronic implanted or percutaneous use in selected casesLess standardized than named-nerve PNS

7 Discussion

The evolution of neuromodulation in pain reflects the constant tension between mechanistic understanding and technological prowess. Initial basic physiology and pathophysiology knowledge historically triggered advances in device precision, which often outpaced the identification of more complex anatomical and network-level mechanisms needed to achieve consistent clinical efficacy. A central theme of this review is the divergence between the relatively narrow set of FDA-cleared or approved indications and the much broader published literature spanning additional pain conditions, targets, stimulation paradigms, and outcomes. This distinction matters when interpreting clinical claims, because a larger literature does not necessarily imply regulatory alignment, evidentiary maturity, or translational readiness. Despite advances in device development, anatomical targeting, and regulatory translation, important evidence gaps persist.

7.1 Evidence gaps across electromagnetic neuromodulation modalities

The strength and maturity of evidence remain uneven across electromagnetic neuromodulation approaches. The contrast between FDA-cleared or approved indications summarized in Tables 1, 2 and the broader representative evidence base summarized in Table 3 highlights an important translational gap: many modality-indication pairs remain supported by limited, heterogeneous, or non-definitive evidence despite substantial published literature. Although this narrative review does not apply a formal evidence-rating framework, this organization provides a narrative assessment of the relative maturity, limitations, and translational readiness of the available literature.

Several recurring evidence gaps can be grouped into methodological, dosing/programming, comparator selection, sham credibility, blinding, outcome, and technical domains. Methodologically, many studies are limited by small sample sizes, short follow-up durations, and heterogeneous patient populations without adequate stratification. These limitations make it difficult to determine whether inconsistent results reflect true differences in efficacy, differences in patient selection, or variability in trial design. With respect to dosing and programming, stimulation parameters are highly variable and often incompletely reported. The modality-specific differences summarized in Table 4 further illustrate the importance of clearly reporting targets, stimulation parameters, treatment schedules, and implementation details. Many studies do not clearly distinguish the nominal, protocol-specified regimen from the treatment actually administered, which may vary because of titration, placement variability, adherence, session completion, and protocol deviations.

Comparator selection, sham credibility, and blinding limitations may also complicate interpretation across both noninvasive and implanted interventions. In neuromodulation trials, active stimulation can produce sensory, auditory, procedural, autonomic, or device-related cues that are difficult to reproduce in sham conditions. In rTMS, many sham methods have historically failed to reproduce the look, sound, and somatosensory experience of active stimulation while avoiding delivery of a significant magnetic field (219). For tDCS, brief ramp-up stimulation followed by discontinuation at the beginning and end of treatment sessions can produce comparable early cutaneous sensations and support blinding under specific stimulation parameters (220). In implanted neuromodulation, particularly SCS, comparator selection, sham design, and blinding are also challenging because paresthesia, device programming, patient interaction with implanted hardware, and incomplete reporting of sham procedures can affect interpretation (221). Because pain outcomes are subjective and sensitive to expectations, placebo analgesia and nonspecific procedural effects can be difficult to separate from stimulation-specific effects in neuromodulation trials (222). Inadequate sham control or incomplete blinding may therefore inflate apparent treatment effects when participants can infer treatment assignment. These issues limit interpretability when comparator methods, sham credibility, and blinding integrity are incompletely reported or not formally assessed.

Outcome heterogeneity is another recurring limitation, as trials differ substantially in their assessment of pain intensity, function, quality of life, sleep, mood, medication use, and durability of benefit. This variability makes it difficult to compare modalities or determine whether short-term pain reduction translates into sustained clinical benefit. Additional technical limitations include limited precision in target engagement, insufficient mechanistic biomarkers, incomplete personalization of stimulation parameters, and limited development of adaptive or closed-loop control strategies. Together, these methodological, dosing/programming, comparator, sham, blinding, outcome, and technical gaps make it difficult to draw firm conclusions about efficacy, durability, comparative effectiveness across modalities, or which patient populations are most likely to benefit.

7.2 Future directions

Future work should focus on adequately powered multi-center trials with standardized reporting of stimulation parameters, longer follow-up to evaluate durability and tolerance, and harmonized core outcomes that include function and quality of life. To improve interpretability and enable cross-study comparison, future trials of electromagnetic neuromodulation for pain should report, at minimum, the following, organized by domain:

Population and condition: The pain condition and diagnostic criteria, and patient characteristics relevant to treatment response (e.g., pain phenotype, duration, prior therapies).

Stimulation and delivery: The stimulation target and localization method, device type, planned (nominal) stimulation parameters, session number and duration, and overall treatment schedule. Critically, trials should also report the treatment actually delivered, distinguishing it from the nominal protocol, since titration, parameter adjustment, adherence, session completion, and protocol deviations can cause planned and delivered treatments to differ.

Comparator and blinding: The comparator or sham procedure in sufficient detail to judge its credibility, and whether and how blinding was assessed.

Clinical and safety outcomes: Prespecified pain intensity, function, quality of life, medication use, and adverse events, each with follow-up duration adequate to assess durability. Where feasible, trials should report not only pain and function but whether functional gains track analgesic gains, as these two outcomes may diverge.

Modality-specific reporting: For invasive approaches, implantation and procedural variables (lead type and position, target verification). For noninvasive approaches used repeatedly outside the clinic, particularly transcutaneous or home-capable modalities, studies should report placement verification, intensity-adjustment procedures, adherence to the prescribed schedule, and device-recorded usage logs where available.

Improved phenotyping and prespecified subgroup analyses are needed to refine patient selection for specific interventions. Mechanistic and target-engagement measures, such as sensory profiling, autonomic metrics, and neurophysiology, may also help optimize stimulation parameters and complement patient-reported and functional outcomes by assessing whether the intended biological target is being engaged. Future studies should define more clearly where each modality fits within the clinical care pathway, including integration with multimodal pain management, long-term safety and maintenance considerations, and practical issues of implementation, access, and reimbursement. Lastly, emerging adaptive and closed-loop neuromodulation systems represent an effort to address a central limitation of earlier approaches (i.e., the lack of real-time feedback linking stimulation delivery to physiological effect and clinical response). The addition of sensing capabilities and biomarker-driven adjustment of stimulation parameters may help bridge the gap between mechanistic modulation and consistent therapeutic efficacy.

Generative AI statement

The author(s) declared that Generative AI was used in the creation of this manuscript. Any use of generative artificial intelligence (e.g., ChatGPT by OpenAI) tools was limited to editorial assistance, formatting, figure improvement, and language refinement, without generating or altering the scientific content.

Any alternative text (alt text) provided alongside figures in this article has been generated by Frontiers with the support of artificial intelligence and reasonable efforts have been made to ensure accuracy, including review by the authors wherever possible. If you identify any issues, please contact us.

Publisher's note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Footnotes

Edited by: Xueshu Tao, The First Affiliated Hospital of China Medical University, China

Reviewed by: Chang-Chia Liu, University of Virginia, United States

Gabrielly Santos Pereira, University of São Paulo, Brazil

Statements

Conflict of interest

LD and TW are officers at Highland Instruments, a medical device company. They have patents pending or issued, personally or as officers in the company, related to imaging, brain stimulation, diagnostics, modeling, and simulation.

The remaining author(s) declared that this work was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

The author FF declared that they were an editorial board member of Frontiers, at the time of submission. This had no impact on the peer review process and the final decision.

Funding

The author(s) declared that financial support was received for this work and/or its publication. Work reported in this publication are or were supported in part by the National Institute of Health NIA (Award Number R44AG055360 and 1SB1AG091887), NIAMS (Award Number 1R44AR076885 and 1SB1AR083748), NINDS (Award Number R44NS110237), and NIDA (Award Number 4R44DA049685 and R43DA058979). The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.

Author contributions

LD: Writing – original draft, Writing – review & editing. CR-E: Writing – review & editing. PG-M: Writing – review & editing. AG: Writing – review & editing. AW: Writing – review & editing. CR: Writing – review & editing. SH: Writing – review & editing. FF: Writing – review & editing. TW: Writing – review & editing.

References

  1. 1. Largus S. Scribonii Largi Compositiones. Sconocchia S, editor. Leipzig: B. G. Teubner (1983).
  2. 2. Pascual-Leone A, Wagner T. A brief summary of the history of noninvasive brain stimulation. Annu Rev Biomed Eng. (2007) 9: s1 – 7.
  3. 3. Tsoucalas G, Karamanou M, Lymperi M, Gennimata V, Androutsos G. The “torpedo” effect in medicine. Int Marit Health. (2014) 65 (2): 65 – 7. doi:10.5603/IMH.2014.0015
  4. 4. Peterson JTB, Deer TR. A history of neurostimulation. In: Deer MSL TR, Buvanendran A, Kim PS, Panchal SJ, editors. Treatment of Chronic Pain by Interventional Approaches the American Academy of Pain Medicine Textbook on Patient Management. New York: Springer (2015), p. 379 – 82.
  5. 5. Kane K, Taub A. A history of local electrical analgesia. Pain. (1975) 1 (2): 125 – 38. doi:10.1016/0304-3959(75)90097-4
  6. 6. Galvani L. De viribus electricitatis in motu musculari commentarius. Bologna, Italy: Ex Typographia Instituti Scientiarum (1791).
  7. 7. Aldini G. Essai théorique et expérimental sur le galvanisme, avec une série d’expériences faites en présence des commissaires de l’Institut national de France, et en divers amphithéâtres anatomiques de Londres. Paris, France: De l’Imprimerie de Fournier fils (1804).
  8. 8. Parent A. Giovanni Aldini: from animal electricity to human brain stimulation. Can J Neurol Sci. (2004) 31 (4): 576 – 84. doi:10.1017/S0317167100003851
  9. 9. Gwathmey JT, Baskerville C. Anesthesia. New York and London: D. Appleton and company (1914).
  10. 10. Reynolds DV. Surgery in the rat during electrical analgesia induced by focal brain stimulation. Science. (1969) 164 (3878): 444 – 5. doi:10.1126/science.164.3878.444
  11. 11. Adams JE, Hosobuchi Y, Fields HL. Stimulation of internal capsule for relief of chronic pain. J Neurosurg. (1974) 41 (6): 740 – 4. doi:10.3171/jns.1974.41.6.0740
  12. 12. Hosobuchi Y, Adams JE, Linchitz R. Pain relief by electrical stimulation of the central gray matter in humans and its reversal by naloxone. Science. (1977) 197 (4299): 183 – 6. doi:10.1126/science.301658
  13. 13. Adams JE. Naloxone reversal of analgesia produced by brain stimulation in the human. Pain. (1976) 2 (2): 161 – 6. doi:10.1016/0304-3959(76)90111-1
  14. 14. Barker AT, Jalinous R, Freeston IL. Non-invasive magnetic stimulation of human motor cortex. Lancet. (1985) 1 (8437): 1106 – 7. doi:10.1016/S0140-6736(85)92413-4
  15. 15. Melzack R, Wall PD. Pain mechanisms: a new theory. Science. (1965) 150 (3699): 971 – 9. doi:10.1126/science.150.3699.971
  16. 16. Woolf CJ. Evidence for a central component of post-injury pain hypersensitivity. Nature. (1983) 306 (5944): 686 – 8. doi:10.1038/306686a0
  17. 17. Ossipov MH, Morimura K, Porreca F. Descending pain modulation and chronification of pain. Curr Opin Support Palliat Care. (2014) 8 (2): 143 – 51. doi:10.1097/SPC.0000000000000055
  18. 18. Woolf CJ. Dissecting out mechanisms responsible for peripheral neuropathic pain: implications for diagnosis and therapy. Life Sci. (2004) 74 (21): 2605 – 10. doi:10.1016/j.lfs.2004.01.003
  19. 19. Burgess PR, Perl ER. Myelinated afferent fibres responding specifically to noxious stimulation of the skin. J Physiol. (1967) 190 (3): 541 – 62. doi:10.1113/jphysiol.1967.sp008227
  20. 20. D'Mello R, Dickenson AH. Spinal cord mechanisms of pain. Br J Anaesth. (2008) 101 (1): 8 – 16. doi:10.1093/bja/aen088
  21. 21. Basbaum AI, Bautista DM, Scherrer G, Julius D. Cellular and molecular mechanisms of pain. Cell. (2009) 139 (2): 267 – 84. doi:10.1016/j.cell.2009.09.028
  22. 22. Mendell LM. Constructing and deconstructing the gate theory of pain. Pain. (2014) 155 (2): 210 – 6. doi:10.1016/j.pain.2013.12.010
  23. 23. Craig AD, Bushnell MC, Zhang ET, Blomqvist A. A thalamic nucleus specific for pain and temperature sensation. Nature. (1994) 372 (6508): 770 – 3. doi:10.1038/372770a0
  24. 24. Talbot JD, Marrett S, Evans AC, Meyer E, Bushnell MC, Duncan GH. Multiple representations of pain in human cerebral cortex. Science. (1991) 251 (4999): 1355 – 8. doi:10.1126/science.2003220
  25. 25. Jones AK, Brown WD, Friston KJ, Qi LY, Frackowiak RS. Cortical and subcortical localization of response to pain in man using positron emission tomography. Proc Biol Sci. (1991) 244 (1309): 39 – 44. doi:10.1098/rspb.1991.0048
  26. 26. Peyron R, Laurent B, Garcia-Larrea L. Functional imaging of brain responses to pain. A review and meta-analysis (2000). Neurophysiol Clin. (2000) 30 (5): 263 – 88. doi:10.1016/S0987-7053(00)00227-6
  27. 27. Millan MJ. Descending control of pain. Prog Neurobiol. (2002) 66 (6): 355 – 474. doi:10.1016/S0301-0082(02)00009-6
  28. 28. Basbaum AI, Fields HL. Endogenous pain control systems: brainstem spinal pathways and endorphin circuitry. Annu Rev Neurosci. (1984) 7: 309 – 38. doi:10.1146/annurev.ne.07.030184.001521
  29. 29. Woolf CJ. Central sensitization: implications for the diagnosis and treatment of pain. Pain. (2011) 152 (3 Suppl): S2 – S15. doi:10.1016/j.pain.2010.09.030
  30. 30. Phillips K, Clauw DJ. Central pain mechanisms in chronic pain states–maybe it is all in their head. Best Pract Res Clin Rheumatol. (2011) 25 (2): 141 – 54. doi:10.1016/j.berh.2011.02.005
  31. 31. Finnerup NB, Haroutounian S, Kamerman P, Baron R, Bennett DLH, Bouhassira D. Neuropathic pain: an updated grading system for research and clinical practice. Pain. (2016) 157 (8): 1599 – 606. doi:10.1097/j.pain.0000000000000492
  32. 32. Latremoliere A, Woolf CJ. Central sensitization: a generator of pain hypersensitivity by central neural plasticity. J Pain. (2009) 10 (9): 895 – 926. doi:10.1016/j.jpain.2009.06.012
  33. 33. Aslam A, Singh J, Rajbhandari S. Pathogenesis of painful diabetic neuropathy. Pain Res Treat. (2014) 2014: 412041. doi:10.1155/2014/412041
  34. 34. Chen SR, Pan HL. Hypersensitivity of spinothalamic tract neurons associated with diabetic neuropathic pain in rats. J Neurophysiol. (2002) 87 (6): 2726 – 33. doi:10.1152/jn.2002.87.6.2726
  35. 35. Silva M, Amorim D, Almeida A, Tavares I, Pinto-Ribeiro F, Morgado C. Pronociceptive changes in the activity of rostroventromedial medulla (RVM) pain modulatory cells in the streptozotocin-diabetic rat. Brain Res Bull. (2013) 96: 39 – 44. doi:10.1016/j.brainresbull.2013.04.008
  36. 36. Chen X, Levine JD. Hyper-responsivity in a subset of C-fiber nociceptors in a model of painful diabetic neuropathy in the rat. Neuroscience. (2001) 102 (1): 185 – 92. doi:10.1016/S0306-4522(00)00454-1
  37. 37. Suzuki R, Dickenson A. Spinal and supraspinal contributions to central sensitization in peripheral neuropathy. Neurosignals. (2005) 14 (4): 175 – 81. doi:10.1159/000087656
  38. 38. DosSantos MF, Ferreira N, Toback RL, Carvalho AC, DaSilva AF. Potential mechanisms supporting the value of motor Cortex stimulation to treat chronic pain syndromes. Front Neurosci. (2016) 10: 18. doi:10.3389/fnins.2016.00018
  39. 39. Tsubokawa T, Katayama Y, Yamamoto T, Hirayama T, Koyama S. Chronic motor cortex stimulation for the treatment of central pain. Acta Neurochir Suppl (Wien). (1991) 52: 137 – 9. doi:10.1007/978-3-7091-9160-6_37
  40. 40. Brown JA, Barbaro NM. Motor cortex stimulation for central and neuropathic pain: current status. Pain. (2003) 104 (3): 431 – 5. doi:10.1016/S0304-3959(03)00209-4
  41. 41. Meyerson BA, Lindblom U, Linderoth B, Lind G, Herregodts P. Motor cortex stimulation as treatment of trigeminal neuropathic pain. Acta Neurochir Suppl (Wien). (1993) 58: 150 – 3. doi:10.1007/978-3-7091-9297-9_34
  42. 42. Migita K, Uozumi T, Arita K, Monden S. Transcranial magnetic coil stimulation of motor cortex in patients with central pain. Neurosurgery. (1995) 36 (5): 1037 – 9; discussion 9–40. doi:10.1227/00006123-199505000-00025
  43. 43. Peyron R, Garcia-Larrea L, Deiber MP, Cinotti L, Convers P, Sindou M. Electrical stimulation of precentral cortical area in the treatment of central pain: electrophysiological and PET study. Pain. (1995) 62 (3): 275 – 86. doi:10.1016/0304-3959(94)00211-V
  44. 44. Mogilner AY, Rezai AR. Epidural motor cortex stimulation with functional imaging guidance. Neurosurg Focus. (2001) 11 (3): E4. doi:10.3171/foc.2001.11.3.5
  45. 45. Pirotte B, Voordecker P, Neugroschl C, Baleriaux D, Wikler D, Metens T. Combination of functional magnetic resonance imaging-guided neuronavigation and intraoperative cortical brain mapping improves targeting of motor cortex stimulation in neuropathic pain. Neurosurgery. (2005) 56 (2 Suppl): 344 – 59: discussion -59. doi:10.1227/01.NEU.0000144837.31665.29
  46. 46. Henderson JM, Boongird A, Rosenow JM, LaPresto E, Rezai AR. Recovery of pain control by intensive reprogramming after loss of benefit from motor cortex stimulation for neuropathic pain. Stereotact Funct Neurosurg. (2004) 82 (5-6): 207 – 13. doi:10.1159/000082447
  47. 47. Henssen D, Kurt E, Van Walsum AVC, Kozicz T, Van Dongen R, Bartels R. Motor cortex stimulation in chronic neuropathic orofacial pain syndromes: a systematic review and meta-analysis. Sci Rep. (2020) 10 (1): 7195. doi:10.1038/s41598-020-64177-z
  48. 48. Garcia-Larrea L, Peyron R. Motor cortex stimulation for neuropathic pain: from phenomenology to mechanisms. Neuroimage. (2007) 37 (Suppl 1): S71 – 9. doi:10.1016/j.neuroimage.2007.05.062
  49. 49. Gan Z, Gangadharan V, Liu S, Körber C, Tan LL, Li H. Layer-specific pain relief pathways originating from primary motor cortex. Science. (2022) 378 (6626): 1336 – 43. doi:10.1126/science.add4391
  50. 50. Fontaine D, Hamani C, Lozano A. Efficacy and safety of motor cortex stimulation for chronic neuropathic pain: critical review of the literature. J Neurosurg. (2009) 110 (2): 251 – 6. doi:10.3171/2008.6.17602
  51. 51. Mo J-J, Hu W-H, Zhang C, Wang X, Liu C, Zhao B-T. Motor cortex stimulation: a systematic literature-based analysis of effectiveness and case series experience. BMC Neurol. (2019) 19 (1): 48. doi:10.1186/s12883-019-1273-y
  52. 52. Hamani C, Fonoff ET, Parravano DC, Silva VA, Galhardoni R, Monaco BA. Motor cortex stimulation for chronic neuropathic pain: results of a double-blind randomized study. Brain. (2021) 144 (10): 2994 – 3004. doi:10.1093/brain/awab189
  53. 53. Lefaucheur JP, Keravel Y, Nguyen JP. Treatment of poststroke pain by epidural motor cortex stimulation with a new octopolar lead. Neurosurgery. (2011) 68 (1 Suppl Operative): 180 – 7; discussion 7. doi:10.1227/NEU.0b013e318207f896
  54. 54. Cruccu G, Garcia-Larrea L, Hansson P, Keindl M, Lefaucheur J-P, Paulus W. EAN Guidelines on central neurostimulation therapy in chronic pain conditions. Eur J Neurol. (2016) 23 (10): 1489 – 99. doi:10.1111/ene.13103
  55. 55. Ramos-Fresnedo A, Perez-Vega C, Domingo RA, Cheshire WP, Middlebrooks EH, Grewal SS. Motor cortex stimulation for pain: a narrative review of indications, techniques, and outcomes. Neuromodulation. (2022) 25 (2): 211 – 21. doi:10.1016/j.neurom.2021.10.025
  56. 56. Gardner J. A history of deep brain stimulation: technological innovation and the role of clinical assessment tools. Soc Stud Sci. (2013) 43 (5): 707 – 28. doi:10.1177/0306312713483678
  57. 57. Heath RG. Studies in Schizophrenia: A Multidisciplinary Approach to Mind-Brain Relationships. Cambridge, MA: Harvard University Press (1954).
  58. 58. Pool JL, Clark WK, Hudson P, Lombardo M. Laboratory and Clinical Assessment. Hypothalamic-Hypophyseal Interrelationships. Springfield, IL: Charles C Thomas (1956).
  59. 59. Schwalb JM, Hamani C. The history and future of deep brain stimulation. Neurotherapeutics. (2008) 5 (1): 3 – 13. doi:10.1016/j.nurt.2007.11.003
  60. 60. Heath RG, Mickle WA. Evaluation of seven years’ experience with depth electrode studies in human patients. In: Ramey ER, O’Doherty DS, editors. Electrical Studies on the Unanesthetized Brain. New York, NY: Paul B. Hoeber (1960), p. 214 – 47.
  61. 61. Fields HL, Adams JE. Pain after cortical injury relieved by electrical stimulation of the internal capsule. Brain. (1974) 97 (1): 169 – 78. doi:10.1093/brain/97.1.169
  62. 62. Mazars G, Merienne L, Ciolocca C. Intermittent analgesic thalamic stimulation. Preliminary note. Rev Neurol (Paris). (1973) 128 (4): 273 – 9.
  63. 63. Richardson DE, Akil H. Pain reduction by electrical brain stimulation in man. Part 2: chronic self-administration in the periventricular gray matter. J Neurosurg. (1977) 47 (2): 184 – 94. doi:10.3171/jns.1977.47.2.0184
  64. 64. Richardson DE, Akil H. Pain reduction by electrical brain stimulation in man. Part 1: acute administration in periaqueductal and periventricular sites. J Neurosurg. (1977) 47 (2): 178 – 83. doi:10.3171/jns.1977.47.2.0178
  65. 65. Levy RM, Lamb S, Adams JE. Treatment of chronic pain by deep brain stimulation: long term follow-up and review of the literature. Neurosurgery. (1987) 21 (6): 885 – 93. doi:10.1227/00006123-198712000-00017
  66. 66. Keifer OP Jr, Riley JP, Boulis NM. Deep brain stimulation for chronic pain: intracranial targets, clinical outcomes, and trial design considerations. Neurosurg Clin N Am. (2014) 25 (4): 671 – 92. doi:10.1016/j.nec.2014.07.009
  67. 67. Coffey RJ. Deep brain stimulation for chronic pain: results of two multicenter trials and a structured review. Pain Med. (2001) 2 (3): 183 – 92. doi:10.1046/j.1526-4637.2001.01029.x
  68. 68. Administration USFaD. Summary of Safety and Effectiveness Data (SSED): Medtronic DBS System for Epilepsy, P960009/S219 (2018).
  69. 69. Paff M, Loh A, Sarica C, Lozano AM, Fasano A. Update on current technologies for deep brain stimulation in Parkinson’s disease. J Mov Disord. (2020) 13 (3): 185 – 98. doi:10.14802/jmd.20052
  70. 70. Amon A, Alesch F. Systems for deep brain stimulation: review of technical features. J Neural Transm (Vienna). (2017) 124 (9): 1083 – 91. doi:10.1007/s00702-017-1751-6
  71. 71. Sarem-Aslani A, Mullett K. Industrial perspective on deep brain stimulation: history, current state, and future developments. Front Integr Neurosci. (2011) 5: 46. doi:10.3389/fnint.2011.00046
  72. 72. Volkmann J, Herzog J, Kopper F, Deuschl G. Introduction to the programming of deep brain stimulators. Mov Disord. (2002) 17 (Suppl 3): S181 – 7. doi:10.1002/mds.10162
  73. 73. Lempka SF, Johnson MD, Miocinovic S, Vitek JL, McIntyre CC. Current-controlled deep brain stimulation reduces in vivo voltage fluctuations observed during voltage-controlled stimulation. Clin Neurophysiol. (2010) 121 (12): 2128 – 33. doi:10.1016/j.clinph.2010.04.026
  74. 74. Steigerwald F, Muller L, Johannes S, Matthies C, Volkmann J. Directional deep brain stimulation of the subthalamic nucleus: a pilot study using a novel neurostimulation device. Mov Disord. (2016) 31 (8): 1240 – 3. doi:10.1002/mds.26669
  75. 75. Ten Brinke TR, Arnts H, Schuurman R, Van Den Munckhof P. Directional sensory thalamus deep brain stimulation in poststroke refractory pain. BMJ Case Rep. (2020) 13 (8): e233254. doi:10.1136/bcr-2019-233254
  76. 76. Krüger MT, Avecillas-Chasin JM, Heran MKS, Naseri Y, Sandhu MK, Polyhronopoulos NE. Directional deep brain stimulation can target the thalamic “sweet spot” for improving neuropathic dental pain. Oper Neurosurg. (2021) 21 (2): 81 – 6. doi:10.1093/ons/opab136
  77. 77. Leplus A, Isan P, Balossier A, Mouffok S, Donnet A, Papadopoulo T. Somatotopy of the sensory thalamus: inputs from directional deep brain stimulation in pain patients. Ann Clin Transl Neurol. (2024) 11 (6): 1502 – 13. doi:10.1002/acn3.52067
  78. 78. Boston Scientific Corporation. Boston Scientific launches Vercise™ Deep Brain Stimulation System in Europe. (2012). Available online at: (Accessed July 31, 2026).
  79. 79. Boston Scientific Corporation. Vercise Genus Deep Brain Stimulation System: Boston Scientific Corporation. Available online at: (Accessed July 31, 2026).
  80. 80. Shirvalkar P, Veuthey TL, Dawes HE, Chang EF. Closed-loop deep brain stimulation for refractory chronic pain. Front Comput Neurosci. (2018) 12: 18. doi:10.3389/fncom.2018.00018
  81. 81. Shirvalkar P, Prosky J, Chin G, Ahmadipour P, Sani OG, Desai M. First-in-human prediction of chronic pain state using intracranial neural biomarkers. Nat Neurosci. (2023) 26 (6): 1090 – 9. doi:10.1038/s41593-023-01338-z
  82. 82. Bittar RG, Kar-Purkayastha I, Owen SL, Bear RE, Green A, Wang SY. Deep brain stimulation for pain relief: a meta-analysis. J Clin Neurosci. (2005) 12 (5): 515 – 9. doi:10.1016/j.jocn.2004.10.005
  83. 83. Shaheen N, Shaheen A, Elgendy A, Bezchlibnyk YB, Zesiewicz T, Dalm B. Deep brain stimulation for chronic pain: a systematic review and meta-analysis. Front Hum Neurosci. (2023) 17: 1297894. doi:10.3389/fnhum.2023.1297894
  84. 84. Pereira EA, Aziz TZ. Neuropathic pain and deep brain stimulation. Neurotherapeutics. (2014) 11 (3): 496 – 507. doi:10.1007/s13311-014-0278-x
  85. 85. Farrell SM, Green A, Aziz T. The current state of deep brain stimulation for chronic pain and its context in other forms of neuromodulation. Brain Sci. (2018) 8 (8): 158. doi:10.3390/brainsci8080158
  86. 86. Sims-Williams H, Matthews JC, Talbot PS, Love-Jones S, Brooks JCW, Patel NK. Deep brain stimulation of the periaqueductal gray releases endogenous opioids in humans. Neuroimage. (2017) 146: 833 – 42. doi:10.1016/j.neuroimage.2016.08.038
  87. 87. Young RF, Chambi VI. Pain relief by electrical stimulation of the periaqueductal and periventricular gray matter. Evidence for a non-opioid mechanism. J Neurosurg. (1987) 66 (3): 364 – 71. doi:10.3171/jns.1987.66.3.0364
  88. 88. Boccard SGJ, Fitzgerald JJ, Pereira EAC, Moir L, Van Hartevelt TJ, Kringelbach ML. Targeting the affective component of chronic pain: a case series of deep brain stimulation of the anterior cingulate cortex. Neurosurgery. (2014) 74 (6): 628 – 35; discussion 35–7. doi:10.1227/NEU.0000000000000321
  89. 89. Russo JF, Sheth SA. Deep brain stimulation of the dorsal anterior cingulate cortex for the treatment of chronic neuropathic pain. Neurosurg Focus. (2015) 38 (6): E11. doi:10.3171/2015.3.FOCUS1543
  90. 90. Kachhadia MP, Sibhai I, Vaghela R, Topiwala U, Shaikh JD, Tsai M. Open-loop and closed-loop neuromodulation across neurological disorders toward personalized brain stimulation: a narrative review. Cureus. (2025) 17 (12): e98624. doi:10.7759/cureus.98624
  91. 91. Shealy CN, Mortimer JT, Reswick JB. Electrical inhibition of pain by stimulation of the dorsal columns: preliminary clinical report. Anesth Analg. (1967) 46 (4): 489 – 91. doi:10.1213/00000539-196707000-00025
  92. 92. Lamer TJ, Moeschler SM, Gazelka HM, Hooten WM, Bendel MA, Murad MH. Spinal stimulation for the treatment of intractable spine and limb pain: a systematic review of RCTs and meta-analysis. Mayo Clin Proc. (2019) 94 (8): 1475 – 87. doi:10.1016/j.mayocp.2018.12.037
  93. 93. Ho JS, Poon C, North R, Grubb W, Lempka S, Bikson M. A visual and narrative timeline review of spinal cord stimulation technology and US food and drug administration milestones. Neuromodulation. (2024) 27 (6): 1020 – 5. doi:10.1016/j.neurom.2024.05.006
  94. 94. Hosobuchi Y, Adams JE, Weinstein PR. Preliminary percutaneous dorsal column stimulation prior to permanent implantation. Technical note. J Neurosurg. (1972) 37 (2): 242 – 5. doi:10.3171/jns.1972.37.2.0242
  95. 95. Shatin D, Mullett K, Hults G. Totally implantable spinal cord stimulation for chronic pain: design and efficacy. Pacing Clin Electrophysiol. (1986) 9 (4): 577 – 83. doi:10.1111/j.1540-8159.1986.tb06614.x
  96. 96. North RB, Ewend MG, Lawton MT, Piantadosi S. Spinal cord stimulation for chronic, intractable pain: superiority of “multi-channel” devices. Pain. (1991) 44 (2): 119 – 30. doi:10.1016/0304-3959(91)90125-H
  97. 97. Kapural L, Yu C, Doust MW, Gliner BE, Vallejo R, Sitzman BT. Novel 10-kHz high-frequency therapy (HF10 therapy) is superior to traditional low-frequency spinal cord stimulation for the treatment of chronic back and leg pain: the SENZA-RCT randomized controlled trial. Anesthesiology. (2015) 123 (4): 851 – 60. doi:10.1097/ALN.0000000000000774
  98. 98. Van Buyten JP, Al-Kaisy A, Smet I, Palmisani S, Smith T. High-frequency spinal cord stimulation for the treatment of chronic back pain patients: results of a prospective multicenter European clinical study. Neuromodulation. (2013) 16 (1): 59 – 65; discussion -6. doi:10.1111/ner.12006
  99. 99. De Vos CC, Bom MJ, Vanneste S, Lenders MW, De Ridder D. Burst spinal cord stimulation evaluated in patients with failed back surgery syndrome and painful diabetic neuropathy. Neuromodulation. (2014) 17 (2): 152 – 9. doi:10.1111/ner.12116
  100. 100. De Ridder D, Vanneste S, Plazier M, Van Der Loo E, Menovsky T. Burst spinal cord stimulation: toward paresthesia-free pain suppression. Neurosurgery. (2010) 66 (5): 986 – 90. doi:10.1227/01.NEU.0000368153.44883.B3
  101. 101. De Ridder D, Plazier M, Kamerling N, Menovsky T, Vanneste S. Burst spinal cord stimulation for limb and back pain. World Neurosurg. (2013) 80 (5): 642 – 9 e1. doi:10.1016/j.wneu.2013.01.040
  102. 102. Deer TR, Mekhail N, Provenzano D, Pope J, Krames E, Leong M. The appropriate use of neurostimulation of the spinal cord and peripheral nervous system for the treatment of chronic pain and ischemic diseases: the neuromodulation appropriateness consensus committee. Neuromodulation. (2014) 17 (6): 515 – 50; discussion 50. doi:10.1111/ner.12208
  103. 103. Shanthanna H, Eldabe S, Provenzano DA, Bouche B, Buchser E, Chadwick R. Evidence-based consensus guidelines on patient selection and trial stimulation for spinal cord stimulation therapy for chronic non-cancer pain. Reg Anesth Pain Med. (2023) 48 (6): 273 – 87. doi:10.1136/rapm-2022-104097
  104. 104. Verrills P, Sinclair C, Barnard A. A review of spinal cord stimulation systems for chronic pain. J Pain Res. (2016) 9: 481 – 92. doi:10.2147/JPR.S108884
  105. 105. Chakravarthy K, Reddy R, Al-Kaisy A, Yearwood T, Grider J. A call to action toward optimizing the electrical dose received by neural targets in spinal cord stimulation therapy for neuropathic pain. J Pain Res. (2021) 14: 2767 – 76. doi:10.2147/JPR.S323372
  106. 106. Deer TR, Levy RM, Kramer J, Poree L, Amirdelfan K, Grigsby E. Dorsal root ganglion stimulation yielded higher treatment success rate for complex regional pain syndrome and causalgia at 3 and 12 months: a randomized comparative trial. Pain. (2017) 158 (4): 669 – 81. doi:10.1097/j.pain.0000000000000814
  107. 107. Sdrulla AD, Guan Y, Raja SN. Spinal cord stimulation: clinical efficacy and potential mechanisms. Pain Pract. (2018) 18 (8): 1048 – 67. doi:10.1111/papr.12692
  108. 108. Sivanesan E, Maher DP, Raja SN, Linderoth B, Guan Y. Supraspinal mechanisms of spinal cord stimulation for modulation of pain: five decades of research and prospects for the future. Anesthesiology. (2019) 130 (4): 651 – 65. doi:10.1097/ALN.0000000000002353
  109. 109. Ahmed S, Yearwood T, De Ridder D, Vanneste S. Burst and high frequency stimulation: underlying mechanism of action. Expert Rev Med Devices. (2018) 15 (1): 61 – 70. doi:10.1080/17434440.2018.1418662
  110. 110. Lee KY, Lee D, Kagan ZB, Wang D, Bradley K. Differential modulation of dorsal horn neurons by various spinal cord stimulation strategies. Biomedicines. (2021) 9 (5): 568. doi:10.3390/biomedicines9050568
  111. 111. Linderoth B, Foreman RD. Conventional and novel spinal stimulation algorithms: hypothetical mechanisms of action and comments on outcomes. Neuromodulation. (2017) 20 (6): 525 – 33. doi:10.1111/ner.12624
  112. 112. Kumar K, North R, Taylor R, Sculpher M, Van den Abeele C, Gehring M. Spinal cord stimulation vs. conventional medical management: a prospective, randomized, controlled, multicenter study of patients with failed back surgery syndrome (PROCESS study). Neuromodulation. (2005) 8 (4): 213 – 8. doi:10.1111/j.1525-1403.2005.00027.x
  113. 113. Kemler MA, Barendse GAM, Van Kleef M, De Vet HCW, Rijks CPM, Furnée CA. Spinal cord stimulation in patients with chronic reflex sympathetic dystrophy. N Engl J Med. (2000) 343 (9): 618 – 24. doi:10.1056/NEJM200008313430904
  114. 114. Petersen EA, Stauss TG, Scowcroft JA, Brooks ES, White JL, Sills SM. Effect of high-frequency (10-kHz) spinal cord stimulation in patients with painful diabetic neuropathy: a randomized clinical trial. JAMA Neurol. (2021) 78 (6): 687 – 98. doi:10.1001/jamaneurol.2021.0538
  115. 115. Boston Scientific Neuromodulation Corporation. Boston Scientific Spinal Cord Stimulator Systems: Indications for Use (2024): Available online at: (Accessed July 31, 2026).
  116. 116. U.S. FDA. Prodigy, Proclaim, and Proclaim XR Spinal Cord Stimulation (SCS) Systems—P010032/S189 (February 15, 2023). Available online at: (Accessed July 5, 2026).
  117. 117. Huygen F, Soulanis K, Rtveladze K, Kamra S, Schlueter M. Spinal cord stimulation vs medical management for chronic back and leg pain: a systematic review and network meta-analysis. JAMA Netw Open. (2024) 7 (11): e2444608. doi:10.1001/jamanetworkopen.2024.44608
  118. 118. Traeger AC, Gilbert SE, Harris IA, Maher CG. Spinal cord stimulation for low back pain. Cochrane Database Syst Rev. (2023) 3 (3): CD014789. doi:10.1002/14651858.CD014789.pub2
  119. 119. McAuley J, Van Groningen R, Green C. Spinal cord stimulation for intractable pain following limb amputation. Neuromodulation. (2013) 16 (6): 530 – 6; discussion 6. doi:10.1111/j.1525-1403.2012.00513.x
  120. 120. Jaffee S, Verma R, Vaezi M, Kite T, Tomycz N. A scoping review of spinal cord stimulation for phantom limb pain. Interv Pain Med. (2025) 4 (1): 100571. doi:10.1016/j.inpm.2025.100571
  121. 121. Krames ES. The dorsal root ganglion in chronic pain and as a target for neuromodulation: a review. Neuromodulation. (2015) 18 (1): 24 – 32; discussion doi:10.1111/ner.12247
  122. 122. Harrison C, Epton S, Bojanic S, Green AL, FitzGerald JJ. The efficacy and safety of dorsal root ganglion stimulation as a treatment for neuropathic pain: a literature review. Neuromodulation. (2018) 21 (3): 225 – 33. doi:10.1111/ner.12685
  123. 123. Deer TR, Levy RM, Kramer J, Poree L, Amirdelfan K, Grigsby E. Comparison of paresthesia coverage of patient’s pain: dorsal root ganglion vs. spinal cord stimulation. An ACCURATE study sub-analysis. Neuromodulation. (2019) 22 (8): 930 – 6. doi:10.1111/ner.12920
  124. 124. U.S. FDA. Premarket Approval (PMA): P150004. Axium Neurostimulator System (February 9, 2016). Available online at: (Accessed July 31, 2026).
  125. 125. Deer TR, Pope JE. Dorsal root ganglion stimulation approval by the food and drug administration: advice on evolving the process. Expert Rev Neurother. (2016) 16 (10): 1123 – 5. doi:10.1080/14737175.2016.1206817
  126. 126. Chakravarthy K, Chaudhry H, Williams K, Christo PJ. Review of the uses of vagal nerve stimulation in chronic pain management. Curr Pain Headache Rep. (2015) 19 (12): 54. doi:10.1007/s11916-015-0528-6
  127. 127. Tracey KJ. Physiology and immunology of the cholinergic antiinflammatory pathway. J Clin Invest. (2007) 117 (2): 289 – 96. doi:10.1172/JCI30555
  128. 128. A randomized controlled trial of chronic vagus nerve stimulation for treatment of medically intractable seizures. The Vagus nerve stimulation study group. Neurology. (1995) 45 (2): 224 – 30. doi:10.1212/wnl.45.2.224
  129. 129. Rush AJ, Marangell LB, Sackeim HA, George MS, Brannan SK, Davis SM. Vagus nerve stimulation for treatment-resistant depression: a randomized, controlled acute phase trial. Biol Psychiatry. (2005) 58 (5): 347 – 54. doi:10.1016/j.biopsych.2005.05.025
  130. 130. Lange G, Janal MN, Maniker A, FitzGibbons J, Fobler M, Cook D. Safety and efficacy of vagus nerve stimulation in fibromyalgia: a phase I/II proof of concept trial. Pain Med. (2011) 12 (9): 1406 – 13. doi:10.1111/j.1526-4637.2011.01203.x
  131. 131. Silberstein SD, Mechtler LL, Kudrow DB, Calhoun AH, McClure C, Saper JR. Non-invasive vagus nerve stimulation for the acute treatment of cluster headache: findings from the randomized, double-blind, sham-controlled ACT1 study. Headache. (2016) 56 (8): 1317 – 32. doi:10.1111/head.12896
  132. 132. Duff IT, Likar R, Perruchoud C, Kampusch S, Köstenberger M, Sator S. Clinical efficacy of auricular vagus nerve stimulation in the treatment of chronic and acute pain: a systematic review and meta-analysis. Pain Ther. (2024) 13 (6): 1407 – 27. doi:10.1007/s40122-024-00657-8
  133. 133. Frangos E, Ellrich J, Komisaruk BR. Non-invasive access to the Vagus nerve central projections via electrical stimulation of the external ear: fMRI evidence in humans. Brain Stimul. (2015) 8 (3): 624 – 36. doi:10.1016/j.brs.2014.11.018
  134. 134. Ben-Menachem E, Revesz D, Simon BJ, Silberstein S. Surgically implanted and non-invasive vagus nerve stimulation: a review of efficacy, safety and tolerability. Eur J Neurol. (2015) 22 (9): 1260 – 8. doi:10.1111/ene.12629
  135. 135. Thompson SL, O’Leary GH, Austelle CW, Gruber E, Kahn AT, Manett AJ. A review of parameter settings for invasive and non-invasive Vagus Nerve Stimulation (VNS) applied in neurological and psychiatric disorders. Front Neurosci. (2021) 15: 709436. doi:10.3389/fnins.2021.709436
  136. 136. Costa V, Gianlorenço AC, Andrade MF, Camargo L, Menacho M, Arias Avila M. Transcutaneous vagus nerve stimulation effects on chronic pain: systematic review and meta-analysis. Pain Rep. (2024) 9 (5): e1171. doi:10.1097/PR9.0000000000001171
  137. 137. Austelle CW, Sege CT, Kahn AT, Gregoski MJ, Taylor DL, McTeague LM. Transcutaneous auricular Vagus nerve stimulation attenuates early increases in heart rate associated with the cold pressor test. Neuromodulation. (2024) 27 (7): 1227 – 33. doi:10.1016/j.neurom.2023.07.012
  138. 138. U.S. FDA. 510(k) Premarket Notification: gammaCore Sapphire (K182369) November 27, 2018. Available online at: (Accessed July 31, 2026).
  139. 139. U.S. FDA. De Novo Summary (DEN150048): gammaCore Non-invasive Vagus Nerve Stimulator (2017). Available online at: (Accessed July 31, 2026).
  140. 140. Tesser JRP, Crowley AR, Box EJ, June JP, Wickersham PB, Valenzuela GJ. Vagus nerve-mediated neuroimmune modulation for rheumatoid arthritis: a pivotal randomized controlled trial. Nat Med. (2026) 32 (1): 369 – 78. doi:10.1038/s41591-025-04114-7
  141. 141. Lefaucheur J-P, Aleman A, Baeken C, Benninger DH, Brunelin J, Di Lazzaro V. Evidence-based guidelines on the therapeutic use of repetitive transcranial magnetic stimulation (rTMS): an update (2014–2018). Clin Neurophysiol. (2020) 131 (2): 474 – 528. doi:10.1016/j.clinph.2019.11.002
  142. 142. Klein MM, Treister R, Raij T, Pascual-Leone A, Park L, Nurmikko T. Transcranial magnetic stimulation of the brain: guidelines for pain treatment research. Pain. (2015) 156 (9): 1601 – 14. doi:10.1097/j.pain.0000000000000210
  143. 143. Peterchev AV, Wagner TA, Miranda PC, Nitsche MA, Paulus W, Lisanby SH. Fundamentals of transcranial electric and magnetic stimulation dose: definition, selection, and reporting practices. Brain Stimul. (2012) 5 (4): 435 – 53. doi:10.1016/j.brs.2011.10.001
  144. 144. Wagner T, Valero-Cabre A, Pascual-Leone A. Noninvasive human brain stimulation. Annu Rev Biomed Eng. (2007) 9: 527 – 65. doi:10.1146/annurev.bioeng.9.061206.133100
  145. 145. Sommer M, Alfaro A, Rummel M, Speck S, Lang N, Tings T. Half sine, monophasic and biphasic transcranial magnetic stimulation of the human motor cortex. Clin Neurophysiol. (2006) 117 (4): 838 – 44. doi:10.1016/j.clinph.2005.10.029
  146. 146. Samoudi AM, Tanghe E, Martens L, Joseph W. Deep transcranial magnetic stimulation: improved coil design and assessment of the induced fields using MIDA model. Biomed Res Int. (2018) 2018: 7061420. doi:10.1155/2018/7061420
  147. 147. Huang YZ, Edwards MJ, Rounis E, Bhatia KP, Rothwell JC. Theta burst stimulation of the human motor cortex. Neuron. (2005) 45 (2): 201 – 6. doi:10.1016/j.neuron.2004.12.033
  148. 148. Lefaucheur JP. Use of repetitive transcranial magnetic stimulation in pain relief. Expert Rev Neurother. (2008) 8 (5): 799 – 808. doi:10.1586/14737175.8.5.799
  149. 149. Topper R, Foltys H, Meister IG, Sparing R, Boroojerdi B. Repetitive transcranial magnetic stimulation of the parietal cortex transiently ameliorates phantom limb pain-like syndrome. Clin Neurophysiol. (2003) 114 (8): 1521 – 30. doi:10.1016/S1388-2457(03)00117-2
  150. 150. Brighina F, De Tommaso M, Giglia F, Scalia S, Cosentino G, Puma A. Modulation of pain perception by transcranial magnetic stimulation of left prefrontal cortex. J Headache Pain. (2011) 12 (2): 185 – 91. doi:10.1007/s10194-011-0322-8
  151. 151. Lefaucheur J-P, André-Obadia N, Antal A, Ayache SS, Baeken C, Benninger DH. Evidence-based guidelines on the therapeutic use of repetitive transcranial magnetic stimulation (rTMS). Clin Neurophysiol. (2014) 125 (11): 2150 – 206. doi:10.1016/j.clinph.2014.05.021
  152. 152. Hamid P, Malik BH, Hussain ML. Noninvasive Transcranial Magnetic Stimulation (TMS) in chronic refractory pain: a systematic review. Cureus. (2019) 11 (10): e6019. doi:10.7759/cureus.6019
  153. 153. O'Connell NE, Marston L, Spencer S, DeSouza LH, Wand BM. Non-invasive brain stimulation techniques for chronic pain. Cochrane Database Syst Rev. (2018) 4 (4): CD008208. doi:10.1002/14651858.CD008208.pub5
  154. 154. Nitsche MA, Paulus W. Excitability changes induced in the human motor cortex by weak transcranial direct current stimulation. J Physiol. (2000) 527 (Pt 3): 633 – 9. doi:10.1111/j.1469-7793.2000.t01-1-00633.x
  155. 155. Rothwell J. Transcranial brain stimulation: past and future. Brain Neurosci Adv. (2018) 2: 2398212818818070. doi:10.1177/2398212818818070
  156. 156. Bikson M, Datta A, Elwassif M. Establishing safety limits for transcranial direct current stimulation. Clin Neurophysiol. (2009) 120 (6): 1033 – 4. doi:10.1016/j.clinph.2009.03.018
  157. 157. Seminowicz DA, Moayedi M. The dorsolateral prefrontal cortex in acute and chronic pain. J Pain. (2017) 18 (9): 1027 – 35. doi:10.1016/j.jpain.2017.03.008
  158. 158. Lefaucheur J-P, Antal A, Ayache SS, Benninger DH, Brunelin J, Cogiamanian F. Evidence-based guidelines on the therapeutic use of transcranial direct current stimulation (tDCS). Clin Neurophysiol. (2017) 128 (1): 56 – 92. doi:10.1016/j.clinph.2016.10.087
  159. 159. Roizenblatt S, Fregni F, Gimenez R, Wetzel T, Rigonatti SP, Tufik S. Site-specific effects of transcranial direct current stimulation on sleep and pain in fibromyalgia: a randomized, sham-controlled study. Pain Pract. (2007) 7 (4): 297 – 306. doi:10.1111/j.1533-2500.2007.00152.x
  160. 160. Fregni F, Boggio PS, Lima MC, Ferreira MJL, Wagner T, Rigonatti SP. A sham-controlled, phase II trial of transcranial direct current stimulation for the treatment of central pain in traumatic spinal cord injury. Pain. (2006) 122 (1-2): 197 – 209. doi:10.1016/j.pain.2006.02.023
  161. 161. Kim YJ, Ku J, Kim HJ, Im DJ, Lee HS, Han KA. Randomized, sham controlled trial of transcranial direct current stimulation for painful diabetic polyneuropathy. Ann Rehabil Med. (2013) 37 (6): 766 – 76. doi:10.5535/arm.2013.37.6.766
  162. 162. Antal A, Boros K, Poreisz C, Chaieb L, Terney D, Paulus W. Comparatively weak after-effects of transcranial alternating current stimulation (tACS) on cortical excitability in humans. Brain Stimul. (2008) 1 (2): 97 – 105. doi:10.1016/j.brs.2007.10.001
  163. 163. Antal A, Paulus W. Transcranial alternating current stimulation (tACS). Front Hum Neurosci. (2013) 7: 317. doi:10.3389/fnhum.2013.00317
  164. 164. Neuling T, Rach S, Herrmann CS. Orchestrating neuronal networks: sustained after-effects of transcranial alternating current stimulation depend upon brain states. Front Hum Neurosci. (2013) 7: 161. doi:10.3389/fnhum.2013.00161
  165. 165. Tavakoli AV, Yun K. Transcranial Alternating Current Stimulation (tACS) mechanisms and protocols. Front Cell Neurosci. (2017) 11: 214. doi:10.3389/fncel.2017.00214
  166. 166. Helfrich RF, Knepper H, Nolte G, Strüber D, Rach S, Herrmann CS. Selective modulation of interhemispheric functional connectivity by HD-tACS shapes perception. PLoS Biol. (2014) 12 (12): e1002031. doi:10.1371/journal.pbio.1002031
  167. 167. Mehta AR, Pogosyan A, Brown P, Brittain JS. Montage matters: the influence of transcranial alternating current stimulation on human physiological tremor. Brain Stimul. (2015) 8 (2): 260 – 8. doi:10.1016/j.brs.2014.11.003
  168. 168. Arendsen LJ, Hugh-Jones S, Lloyd DM. Transcranial alternating current stimulation at alpha frequency reduces pain when the intensity of pain is uncertain. J Pain. (2018) 19 (7): 807 – 18. doi:10.1016/j.jpain.2018.02.014
  169. 169. May ES, Hohn VD, Nickel MM, Tiemann L, Gil Ávila C, Heitmann H. Modulating brain rhythms of pain using transcranial alternating current stimulation (tACS)—a sham-controlled study in healthy human participants. J Pain. (2021) 22 (10): 1256 – 72. doi:10.1016/j.jpain.2021.03.150
  170. 170. Ahn S, Prim JH, Alexander ML, McCulloch KL, Frohlich F. Identifying and engaging neuronal oscillations by transcranial alternating current stimulation in patients with chronic low back pain: a randomized, crossover, double-blind, sham-controlled pilot study. J Pain. (2019) 20 (3): 277.e1 – 11. doi:10.1016/j.jpain.2018.09.004
  171. 171. Ploner M, Sorg C, Gross J. Brain rhythms of pain. Trends Cogn Sci. (2017) 21 (2): 100 – 10. doi:10.1016/j.tics.2016.12.001
  172. 172. Bernardi L, Bertuccelli M, Formaggio E, Rubega M, Bosco G, Tenconi E. Beyond physiotherapy and pharmacological treatment for fibromyalgia syndrome: tailored tACS as a new therapeutic tool. Eur Arch Psychiatry Clin Neurosci. (2021) 271 (1): 199 – 210. doi:10.1007/s00406-020-01214-y
  173. 173. Shekelle PG, Cook IA, Miake-Lye IM, Booth MS, Beroes JM, Mak S. Benefits and Harms of cranial electrical stimulation for chronic painful conditions, depression, anxiety, and insomnia: a systematic review. Ann Intern Med. (2018) 168 (6): 414 – 21. doi:10.7326/M17-1970
  174. 174. Guleyupoglu B, Schestatsky P, Edwards D, Fregni F, Bikson M. Classification of methods in transcranial electrical stimulation (tES) and evolving strategy from historical approaches to contemporary innovations. J Neurosci Methods. (2013) 219 (2): 297 – 311. doi:10.1016/j.jneumeth.2013.07.016
  175. 175. Shekelle P, Cook I, Miake-Lye IM, Mak S, Booth MS, Shanman R. The Effectiveness and Risks of Cranial Electrical Stimulation for the Treatment of Pain, Depression, Anxiety, PTSD, and Insomnia: A Systematic Review. VA Evidence-based Synthesis Program Reports. Washington (DC) (2018).
  176. 176. Datta A, Dmochowski JP, Guleyupoglu B, Bikson M, Fregni F. Cranial electrotherapy stimulation and transcranial pulsed current stimulation: a computer based high-resolution modeling study. Neuroimage. (2013) 65: 280 – 7. doi:10.1016/j.neuroimage.2012.09.062
  177. 177. Brunye TT, Patterson JE, Wooten T, Hussey EK. A critical review of cranial electrotherapy stimulation for neuromodulation in clinical and non-clinical samples. Front Hum Neurosci. (2021) 15: 625321. doi:10.3389/fnhum.2021.625321
  178. 178. Taylor AG, Anderson JG, Riedel SL, Lewis JE, Kinser PA, Bourguignon C. Cranial electrical stimulation improves symptoms and functional status in individuals with fibromyalgia. Pain Manag Nurs. (2013) 14 (4): 327 – 35. doi:10.1016/j.pmn.2011.07.002
  179. 179. Lichtbroun AS, Raicer MM, Smith RB. The treatment of fibromyalgia with cranial electrotherapy stimulation. J Clin Rheumatol. (2001) 7 (2): 72 – 8; discussion 8. doi:10.1097/00124743-200104000-00003
  180. 180. Shealy CN, Maurer D. Transcutaneous nerve stimulation for control of pain. A preliminary technical note. Surg Neurol. (1974) 2 (1): 45 – 7.
  181. 181. Long DM, Long DM. Fifteen years of transcutaneous electrical stimulation for pain control. Stereotact Funct Neurosurg. (1991) 56 (1): 2 – 19. doi:10.1159/000099388
  182. 182. Vance CG, Dailey DL, Rakel BA, Sluka KA. Using TENS for pain control: the state of the evidence. Pain Manag. (2014) 4 (3): 197 – 209. doi:10.2217/pmt.14.13
  183. 183. Johnson M. Transcutaneous electrical nerve stimulation: mechanisms, clinical application and evidence. Rev Pain. (2007) 1 (1): 7 – 11. doi:10.1177/204946370700100103
  184. 184. Vance CGT, Dailey DL, Chimenti RL, Van Gorp BJ, Crofford LJ, Sluka KA. Using TENS for pain control: update on the state of the evidence. Medicina (Kaunas). (2022) 58 (10): 1332. doi:10.3390/medicina58101332
  185. 185. Watson T. Transcutaneous Electrical Nerve Stimulation (TENS) (2025). Available online at: (Accessed July 31, 2026).
  186. 186. U.S. FDA. 510(k) Summary: Care Back Pain Relief Stimulator, K110390 (2011). Available online at: (Accessed July 31, 2026).
  187. 187. U.S. FDA. 510(k) Summary: RS-4i Muscle Stimulator, K062325 (2007). Available online at: (Accessed July 31, 2026).
  188. 188. U.S. FDA. 510(k) Summary: TrueRelief Device, K202186 (2021). Available online at: (Accessed July 31, 2026).
  189. 189. Sluka KA, Deacon M, Stibal A, Strissel S, Terpstra A. Spinal blockade of opioid receptors prevents the analgesia produced by TENS in arthritic rats. J Pharmacol Exp Ther. (1999) 289 (2): 840 – 6. doi:10.1016/S0022-3565(24)38209-6
  190. 190. Kalra A, Urban MO, Sluka KA. Blockade of opioid receptors in rostral ventral medulla prevents antihyperalgesia produced by transcutaneous electrical nerve stimulation (TENS). J Pharmacol Exp Ther. (2001) 298 (1): 257 – 63. doi:10.1016/S0022-3565(24)29376-9
  191. 191. Radhakrishnan R, King EW, Dickman JK, Herold CA, Johnston NF, Spurgin ML. Spinal 5-HT(2) and 5-HT(3) receptors mediate low, but not high, frequency TENS-induced antihyperalgesia in rats. Pain. (2003) 105 (1–2): 205 – 13. doi:10.1016/S0304-3959(03)00207-0
  192. 192. Carroll D, Tramer M, McQuay H, Nye B, Moore A. Randomization is important in studies with pain outcomes: systematic review of transcutaneous electrical nerve stimulation in acute postoperative pain. Br J Anaesth. (1996) 77 (6): 798 – 803. doi:10.1093/bja/77.6.798
  193. 193. Reeve J, Menon D, Corabian P. Transcutaneous electrical nerve stimulation (TENS): a technology assessment. Int J Technol Assess Health Care. (1996) 12 (2): 299 – 324. doi:10.1017/S026646230000965X
  194. 194. Paley CA, Wittkopf PG, Jones G, Johnson MI. Does TENS reduce the intensity of acute and chronic pain? A comprehensive appraisal of the characteristics and outcomes of 169 reviews and 49 meta-analyses. Medicina (Kaunas). (2021) 57 (10): 1060. doi:10.3390/medicina57101060
  195. 195. Johnson MI. Transcutaneous electrical nerve stimulation (TENS) as an adjunct for pain management in perioperative settings: a critical review. Expert Rev Neurother. (2017) 17 (10): 1013 – 27. doi:10.1080/14737175.2017.1364158
  196. 196. Johnson MI. Resolving long-standing uncertainty about the clinical efficacy of Transcutaneous Electrical Nerve Stimulation (TENS) to relieve pain: a comprehensive review of factors influencing outcome. Medicina (Kaunas). (2021) 57 (4): 378. doi:10.3390/medicina57040378
  197. 197. Amer-Cuenca JJ, Lisón JF, Ferrer-Sargues FJ, Biviá-Roig G, Baños RM, Badenes-Ribera L. Dose-response effects of transcutaneous electrical nerve stimulation for chronic low back pain: a systematic review and meta-analysis. Eur J Pain. (2026) 30 (2): e70222. doi:10.1002/ejp.70222
  198. 198. Shelden CH, Pudenz RH, Doyle J. Electrical control of facial pain. Am J Surg. (1967) 114 (2): 209 – 12. doi:10.1016/0002-9610(67)90374-1
  199. 199. Wall PD, Sweet WH. Temporary abolition of pain in man. Science. (1967) 155 (3758): 108 – 9. doi:10.1126/science.155.3758.108
  200. 200. Long DM. Electrical stimulation for the control of pain. Arch Surg. (1977) 112 (7): 884 – 8. doi:10.1001/archsurg.1977.01370070098016
  201. 201. Law JD, Swett J, Kirsch WM. Retrospective analysis of 22 patients with chronic pain treated by peripheral nerve stimulation. J Neurosurg. (1980) 52 (4): 482 – 5. doi:10.3171/jns.1980.52.4.0482
  202. 202. Weiner RL, Reed KL. Peripheral neurostimulation for control of intractable occipital neuralgia. Neuromodulation. (1999) 2 (3): 217 – 21. doi:10.1046/j.1525-1403.1999.00217.x
  203. 203. Helm S, Shirsat N, Calodney A, Abd-Elsayed A, Kloth D, Soin A. Peripheral nerve stimulation for chronic pain: a systematic review of effectiveness and safety. Pain Ther. (2021) 10 (2): 985 – 1002. doi:10.1007/s40122-021-00306-4
  204. 204. Deer TR, Eldabe S, Falowski SM, Huntoon MA, Staats PS, Cassar IR. Peripherally induced reconditioning of the central nervous system: a proposed mechanistic theory for sustained relief of chronic pain with percutaneous peripheral nerve stimulation. J Pain Res. (2021) 14: 721 – 36. doi:10.2147/JPR.S297091
  205. 205. Strand N, D’Souza RS, Hagedorn JM, Pritzlaff S, Sayed D, Azeem N. Evidence-based clinical guidelines from the American society of pain and neuroscience for the use of implantable peripheral nerve stimulation in the treatment of chronic pain. J Pain Res. (2022) 15: 2483 – 504. doi:10.2147/JPR.S362204
  206. 206. Char S, Jin MY, Francio VT, Hussain N, Wang EJ, Morsi M. Implantable peripheral nerve stimulation for peripheral neuropathic pain: a systematic review of prospective studies. Biomedicines. (2022) 10 (10): 2606. doi:10.3390/biomedicines10102606
  207. 207. Paicius RM, Bernstein CA, Lempert-Cohen C. Peripheral nerve field stimulation for the treatment of chronic low back pain: preliminary results of long-term follow-up: a case series. Neuromodulation. (2007) 10 (3): 279 – 90. doi:10.1111/j.1525-1403.2007.00116.x
  208. 208. Krutsch JP, McCeney MH, Barolat G, Al Tamimi M, Smolenski A. A case report of subcutaneous peripheral nerve stimulation for the treatment of axial back pain associated with postlaminectomy syndrome. Neuromodulation. (2008) 11 (2): 112 – 5. doi:10.1111/j.1525-1403.2008.00151.x
  209. 209. Verrills P, Vivian D, Mitchell B, Barnard A. Peripheral nerve field stimulation for chronic pain: 100 cases and review of the literature. Pain Med. (2011) 12 (9): 1395 – 405. doi:10.1111/j.1526-4637.2011.01201.x
  210. 210. Paicius RM, Bernstein CA, Lempert-Cohen C. Peripheral nerve field stimulation in chronic abdominal pain. Pain Physician. (2006) 9 (3): 261 – 6.
  211. 211. Goroszeniuk T, Kothari S, Hamann W. Subcutaneous neuromodulating implant targeted at the site of pain. Reg Anesth Pain Med. (2006) 31 (2): 168 – 71. doi:10.1016/j.rapm.2006.02.001
  212. 212. Bernstein CA, Paicius RM, Barkow SH, Lempert-Cohen C. Spinal cord stimulation in conjunction with peripheral nerve field stimulation for the treatment of low back and leg pain: a case series. Neuromodulation. (2008) 11 (2): 116 – 23. doi:10.1111/j.1525-1403.2008.00152.x
  213. 213. Kloimstein H, Likar R, Kern M, Neuhold J, Cada M, Loinig N. Peripheral nerve field stimulation (PNFS) in chronic low back pain: a prospective multicenter study. Neuromodulation. (2014) 17 (2): 180 – 7. doi:10.1111/ner.12139
  214. 214. Wong CH, Chan TCW, Wong SSC, Russo M, Cheung CW. Efficacy of peripheral nerve field stimulation for the management of chronic low back pain and persistent spinal pain syndrome: a narrative review. Neuromodulation. (2023) 26 (3): 538 – 51. doi:10.1016/j.neurom.2022.07.011
  215. 215. Nascimento RMD, Cavalcanti RL, Souza CG, Chaves G, Macedo LB. Transcranial direct current stimulation combined with peripheral stimulation in chronic pain: a systematic review and meta-analysis. Expert Rev Med Devices. (2023) 20 (2): 121 – 40. doi:10.1080/17434440.2022.2039623
  216. 216. Boggio PS, Amancio EJ, Correa CF, Cecilio S, Valasek C, Bajwa Z. Transcranial DC stimulation coupled with TENS for the treatment of chronic pain: a preliminary study. Clin J Pain. (2009) 25 (8): 691 – 5. doi:10.1097/AJP.0b013e3181af1414
  217. 217. Wagner T, Dipietro L. Novel Methods of Transcranial Stimulation: Electrosonic Stimulation Neuromodulation: Comprehensive Textbook of Principles, Technologies, and Therapies. Amsterdam: Elsevier (2018). p. 1619 – 26.
  218. 218. Dipietro L, Ramos-Estebanez C, Teixeira PEP, Warimpramote J, Hengyotmark A, Noree W. Mapping the Evolution of Neuromodulation: A Data-driven path to Precision and Personalization. Newcastle upon Tyne: Data Science: Theory and Applications: Cambridge Scholars Publishing (In Press).
  219. 219. Mennemeier M, Triggs W, Chelette K, Woods A, Kimbrell T, Dornhoffer J. Sham transcranial magnetic stimulation using electrical stimulation of the scalp. Brain Stimul. (2009) 2 (3): 168 – 73. doi:10.1016/j.brs.2009.02.002
  220. 220. Gandiga PC, Hummel FC, Cohen LG. Transcranial DC stimulation (tDCS): a tool for double-blind sham-controlled clinical studies in brain stimulation. Clin Neurophysiol. (2006) 117 (4): 845 – 50. doi:10.1016/j.clinph.2005.12.003
  221. 221. Duarte RV, McNicol E, Colloca L, Taylor RS, North RB, Eldabe S. Randomized placebo-/sham-controlled trials of spinal cord stimulation: a systematic review and methodological appraisal. Neuromodulation. (2020) 23 (1): 10 – 8. doi:10.1111/ner.13018
  222. 222. Price DD, Finniss DG, Benedetti F. A comprehensive review of the placebo effect: recent advances and current thought. Annu Rev Psychol. (2008) 59: 565 – 90. doi:10.1146/annurev.psych.59.113006.095941
  223. 223. Eldabe S, Nevitt S, Hunter CW, Rosenow JM, Maden M, Goudman L. Systematic review and network meta-analysis of randomized trial evidence of spinal cord stimulation for chronic pain. Reg Anesth Pain Med. (2026). doi:10.1136/rapm-2025-107068
  224. 224. Pollard EM, Lamer TJ, Moeschler SM, Gazelka HM, Hooten WM, Bendel MA. The effect of spinal cord stimulation on pain medication reduction in intractable spine and limb pain: a systematic review of randomized controlled trials and meta-analysis. J Pain Res. (2019) 12: 1311 – 24. doi:10.2147/JPR.S186662
  225. 225. Shao P, Li H, Jiang J, Guan Y, Chen X, Wang Y. Role of Vagus nerve stimulation in the treatment of chronic pain. Neuroimmunomodulation. (2023) 30 (1): 167 – 83. doi:10.1159/000531626
  226. 226. Song D, Li P, Wang Y, Cao J. Noninvasive vagus nerve stimulation for migraine: a systematic review and meta-analysis of randomized controlled trials. Front Neurol. (2023) 14: 1190062. doi:10.3389/fneur.2023.1190062
  227. 227. Fernandez-Hernando D, Justribo Manion C, Pareja JA, Garcia-Esteo FJ, Mesa-Jimenez JA. Effects of non-invasive neuromodulation of the Vagus nerve for the management of cluster headache: a systematic review. J Clin Med. (2023) 12 (19): 6315. doi:10.3390/jcm12196315
  228. 228. Alwardat M, Pisani A, Etoom M, Carpenedo R, Chinè E, Dauri M. Is transcranial direct current stimulation (tDCS) effective for chronic low back pain? A systematic review and meta-analysis. J Neural Transm (Vienna). (2020) 127 (9): 1257 – 70. doi:10.1007/s00702-020-02223-w
  229. 229. Jiang X, Yan W, Wan R, Lin Y, Zhu X, Song G. Effects of repetitive transcranial magnetic stimulation on neuropathic pain: a systematic review and meta-analysis. Neurosci Biobehav Rev. (2022) 132: 130 – 41. doi:10.1016/j.neubiorev.2021.11.037
  230. 230. Zhu PA, Xie JY, Liu H, Wen Y, Shao YJ, Bao X. Efficacy of high-frequency repetitive transcranial magnetic stimulation at 10 Hz in fibromyalgia: a systematic review and meta-analysis. Arch Phys Med Rehabil. (2023) 104 (1): 151 – 9. doi:10.1016/j.apmr.2022.05.006
  231. 231. Bouhassira D, Jazat-Poindessous F, Farnes N, Franchisseur C, Stubhaug A, Bismuth J. Comparison of the analgesic effects of “superficial” and “deep” repetitive transcranial magnetic stimulation in patients with central neuropathic pain: a randomized sham-controlled multicenter international crossover study. Pain. (2024) 165 (4): 884 – 92. doi:10.1097/j.pain.0000000000003082
  232. 232. Mussigmann T, Bardel B, Lefaucheur JP. Expectations related to the use of theta burst stimulation protocols for pain relief. A systematic review. Clin Neurophysiol. (2025) 176: 2110768. doi:10.1016/j.clinph.2025.2110768
  233. 233. Chang MC, Briand MM, Boudier-Reveret M, Yang S. Effectiveness of transcranial alternating current stimulation for controlling chronic pain: a systematic review. Front Neurol. (2023) 14: 1323520. doi:10.3389/fneur.2023.1323520
  234. 234. Johnson MI, Paley CA, Jones G, Mulvey MR, Wittkopf PG. Efficacy and safety of transcutaneous electrical nerve stimulation (TENS) for acute and chronic pain in adults: a systematic review and meta-analysis of 381 studies (the meta-TENS study). BMJ Open. (2022) 12 (2): e051073. doi:10.1136/bmjopen-2021-051073
  235. 235. Johnson MI, Claydon LS, Herbison GP, Jones G, Paley CA. Transcutaneous electrical nerve stimulation (TENS) for fibromyalgia in adults. Cochrane Database Syst Rev. (2017) 10 (10): CD012172. doi:10.1002/14651858.CD012172.pub2
  236. 236. Garcia-Lopez H, Calle-Ortega F, Garcia-Robles P, Del-Rey RR, Obrero-Gaitan E, Cortes-Perez I. Effectiveness of transcutaneous electrical nerve stimulation improves pain intensity, disability and quality of life in patients with fibromyalgia syndrome: a systematic review with meta-analysis. Disabil Rehabil. (2024) 46 (26): 6323 – 33. doi:10.1080/09638288.2024.2331069
  237. 237. Wilson RD, Gunzler DD, Bennett ME, Chae J. Peripheral nerve stimulation compared with usual care for pain relief of hemiplegic shoulder pain: a randomized controlled trial. Am J Phys Med Rehabil. (2014) 93 (1): 17 – 28. doi:10.1097/PHM.0000000000000011
  238. 238. McRoberts WP, Wolkowitz R, Meyer DJ, Lipov E, Joshi J, Davis B. Peripheral nerve field stimulation for the management of localized chronic intractable back pain: results from a randomized controlled study. Neuromodulation. (2013) 16 (6): 565 – 74; discussion 74–5. doi:10.1111/ner.12055
  239. 239. Choi JH, Choi SC, Kim DK, Sung CH, Chon JY, Hong SJ. Combined spinal cord stimulation and peripheral nerve stimulation for brachial plexopathy: a case report. Pain Physician. (2016) 19 (3): E459 – 63.

Citation

Dipietro, L., et al. (2026). Electromagnetic neuromodulation for chronic pain: historical context, contemporary modalities, and evidence gaps. Frontiers in Pain Research, Volume 7. https://doi.org/
Received
Accepted
Published
Volume
7 - 2026

Copyright

© 2026 Dipietro, Ramos-Estebanez, Gonzalez-Mego, Gianlorenco, Wongtanawat, Robinson, Hayek, Fregni and Wagner.

License: https://creativecommons.org/licenses/by/4.0/

*Correspondence: Laura Dipietro

Article metrics

Views
0
Downloads
0
Citations
0
Shares
0