Effect of urine storage conditions on circulating anodic antigen detection using the UCP-LF CAA test

  • Pytsje T. Hoekstra1*corresponding author
  • Govert J. van Dam1
  • Maureen Blokland-Flink1
  • Danielle de Jong2
  • Said M. Ali3
  • Mohammed N. Ali3
  • Naomi C. Ndum4,5
  • Stefanie Knopp4,5
  • Paul L.A.M. Corstjens2
  • Lisette van Lieshout1
  1. 1Leiden University Center for Infectious Diseases (LUCID), Leiden University Medical Center, Leiden, Netherlands
  2. 2Department of Cell and Chemical Biology, Leiden University Medical Center, Leiden, Netherlands
  3. 3Public Health Laboratory - Ivo de Carneri, Pemba, Tanzania
  4. 4Swiss Tropical and Public Health Institute, Allschwil, Switzerland
  5. 5University of Basel, Basel, Switzerland
Article metrics0 viewsView details

Abstract

Schistosomiasis is a parasitic neglected tropical disease that remains a major public health problem in many African countries. Accurate diagnosis is essential for control, surveillance and elimination efforts. Conventional parasitological methods have limited sensitivity, particularly in low-intensity infections commonly observed after treatment or in low-endemic settings. Circulating anodic antigen (CAA), released by live Schistosoma worms, is a highly sensitive and specific marker of active infection. The up-converting reporter particle lateral flow (UCP-LF) CAA test enables non-invasive urine-based diagnosis and is increasingly applied in low-endemic and near-elimination settings. For operational feasibility, urine samples may need to be stored before testing, but the effect of different storage conditions on CAA detection has not been systematically evaluated. We investigated the effect of freezing and non-frozen storage on urine CAA detection using the UCP-LF CAA test, compared with freshly tested urine. The study was conducted among school-aged children in a near-elimination Schistosoma haematobium setting on Pemba, Tanzania. A total of 272 urine samples were tested fresh and after freezing at -20 °C for 5-7 days. For a subset of 153 samples with sufficient urine available, an additional aliquot was stored under non-frozen conditions (4-25 °C) and tested approximately 5 weeks after collection. CAA positivity decreased from 44/272 (16.2%) in fresh urine to 35/272 (12.9%) after freezing. In the subset, positivity was 20/153 (13.1%) in fresh, 16/153 (10.5%) in frozen, and 24/153 (15.7%) in non-frozen stored urine. CAA concentrations showed strong correlation between storage conditions (Spearman’s ρ = 0.86–0.93, p<0.0001). Freezing was associated with a small but significant reduction in CAA positivity (p=0.004), while CAA concentrations showed a non-significant trend towards lower values after freezing. Non-frozen stored samples showed generally comparable results to fresh urine. In conclusion, these findings suggest that flexible urine storage strategies may be feasible for delayed centralized CAA testing, although freezing may result in loss of detection among samples with CAA concentrations close to the assay cut-off.

Keywords

1. Introduction

Schistosomiasis is a parasitic disease caused by blood flukes of the genus Schistosoma, affecting over 200 million people worldwide, particularly in sub-Saharan Africa (Buonfrate et al., 2025). Transmission occurs through contact with freshwater contaminated with larval stages released by infected intermediate host snails. Accurate diagnosis of schistosomiasis is essential for effective control, surveillance, and elimination efforts. Conventional parasitological methods, such as urine filtration and stool microscopy, have limited sensitivity, particularly in low-endemic settings as well as after praziquantel treatment, when infection intensities are often low and egg excretion is intermittent (Hoekstra et al., 2021a). Detection of circulating anodic antigen (CAA), released by live Schistosoma worms, offers a sensitive measure of active infection (Corstjens et al., 2020). The up-converting reporter particle lateral flow (UCP-LF) CAA test has demonstrated high specificity and sensitivity for the detection of all Schistosoma species including Schistosoma hybrids and veterinary species (Knopp et al., 2015; van Dam et al., 2015a; van Dam et al., 2015b; Vonghachack et al., 2017; Clements et al., 2018; Sousa et al., 2019; Corstjens et al., 2020; Assaré et al., 2021; Hoekstra et al., 2021b) and complements or surpasses traditional egg-detection methods (Knopp et al., 2015; Clements et al., 2018; Assaré et al., 2021; Lorenz et al., 2025). CAA detection is increasingly applied across different settings, including low-endemic and near-elimination areas (Clements et al., 2018; Sousa et al., 2019; Corstjens et al., 2020; Assaré et al., 2021), post-treatment follow-up and pharmacokinetic and pharmacodynamic studies (Bustinduy et al., 2016; Sousa et al., 2019; Hoekstra et al., 2022a; Bustinduy et al., 2025; de Freitas Galvão et al., 2025), surveillance and sample pooling approaches (Corstjens et al., 2017; Hoekstra et al., 2020; Hoekstra et al., 2022c), non-endemic and migrant populations (Camprubí-Ferrer et al., 2021; Hoekstra et al., 2021b; Tamarozzi et al., 2021; Hoekstra et al., 2022b), and controlled human infection models (Langenberg et al., 2020; Abaasa et al., 2023; Koopman et al., 2023).

The detection of CAA in urine enables non-invasive testing using the UCP-LF CAA test, which can be performed in laboratories with basic equipment, making the test suitable for use in endemic settings (Downs et al., 2012; van Dam et al., 2013; Knopp et al., 2015; Gerstenberg et al., 2024; Bustinduy et al., 2025; Lorenz et al., 2025). For surveillance and research applications, urine samples may be collected in decentralized settings and transported to a central laboratory for subsequent testing. Storage prior to testing can facilitate centralized and retrospective analysis, potentially improving workflow efficiency and data comparability. CAA is considered stable because of its carbohydrate structure, which makes it resistant to degradation under a range of storage conditions, including prolonged storage room temperature, refrigeration, and freezing. This long-term stability of CAA is illustrated by its detection in Egyptian mummies, reflecting its preservation over thousands of years (Deelder et al., 1990; Miller et al., 1992). However, the effect of different urine storage conditions on measurable CAA concentrations has not been systematically evaluated under operational conditions. Here, we evaluated the effect of freezing for 5–7 days at −20 °C and non-frozen storage for approximately 5 weeks at 4-25 °C on CAA detection and concentrations, compared with freshly tested urine, using the UCP-LF CAA test.

2. Materials and methods

Urine samples were collected as part of a prospective diagnostic evaluation study performed among school-aged children in two schools on Pemba Island, United Republic of Tanzania, in February 2025. The main study evaluated the performance of a range of methods for Schistosoma haematobium infection diagnosis in a near-elimination setting (Ndum et al., 2026). CAA testing was prospectively included in the study using both freshly collected urine, tested on the day of collection, and frozen urine, tested after 5–7 days, reflecting the conventional approach used for CAA testing. Both analyses were performed at the Public Health Laboratory-Ivo de Carneri (PHL-IdC) on Pemba. During the study, we additionally introduced a third sample condition to assess a more practical field-to-laboratory scenario: approximately halfway through the study, when sufficient urine volume was available, a third aliquot was retained for non-frozen storage and subsequent transport to the Netherlands for CAA testing. This condition was included because in field settings where freezing is not available, urine may be stored refrigerated before transport. The resulting sample set was therefore smaller than that available for the prospectively planned fresh and frozen conditions. The study population and epidemiological setting have been described previously (Ndum et al.,). Ethical approval and participant consent procedures followed those described in the main study (Ndum et al.,).

The primary objective of the present sub-study was to compare CAA detection in freshly collected and frozen urine samples. This comparison was prospectively planned and performed for all urine samples with sufficient volume available (N = 272). The additional non-frozen condition was assessed in a subset with sufficient remaining urine volume (N = 153).

Urine samples were processed as follows: (1) in the first week, a first 0.5 mL aliquot was tested within 4 hours after collection (fresh) at PHL-IdC in Pemba; (2) a second 0.5 mL aliquot was frozen within 4 hours after collection, stored at −20 °C for 5–7 days, subsequently thawed, and tested at PHL-IdC during the second week; (3) a third 0.5 mL aliquot was stored at 4 °C, transported to the Netherlands under cooled conditions using ice packs at the end of the second week, and tested at the Leiden University Medical Center (LUMC) within 2–3 weeks of arrival. Thus, the third aliquot was tested approximately 5 weeks after sample collection (Figure 1).

UCP-LF CAA testing followed standard procedures as described previously, using the UCAA hT 417 dry format (Corstjens et al., 2020), which was selected based on a combination of high analytical sensitivity and suitability for execution in the field. All samples were analyzed using the same assay format, as well as the same batch of reagents, calibrators and controls and the same UCP-reader; fresh and frozen samples were analyzed on Pemba Island, whereas non-frozen stored samples were transported to and analyzed at LUMC, Leiden, the Netherlands. Briefly, samples were pre-treated with 12% trichloroacetic acid (TCA) to release CAA and precipitate proteins. Subsequently, 0.5 mL of the clear supernatant was concentrated using Millipore Amicon centrifugal filtration devices (Merck Chemicals BV, Amsterdam, the Netherlands) with a 10-kDa filter. Finally, the concentrated sample (20uL) was mixed with 100 μL assay buffer containing 50 ng of the highly sensitive reporter label (UCP; NaYF 4:Yb 3+,Er3+, 110x80 nm prisms; Intelligent Material Solutions, Princeton, NJ, USA). UCP materials were conjugated to anti-CAA antibodies and provided as freeze dried pellets (LyoSpheres™, batch #230718_540, BIOLYPH, Chaska, MN, USA). Lateral flow strips, comprising a test line with anti-CAA antibodies (batch #1745, MaximBio, Rockville, MD, USA), were added to the wells and immunochromatography was allowed for at least 3 hours. After incubation, bound CAA-UCP complexes were detected by scanning the LF strips with an ESEQuant reader (LR3, DIALUNOX, USA) adapted for the UCP-label (van Dam et al., 2013). In each run, a serial dilution series of a TCA-treated crude adult worm antigen (AWA-TCA) preparation spiked in CAA-negative urine was included to validate the cut-off of the test (2 pg/ml for the UCAA hT 417 dry format) as well as to quantify the CAA concentration in the unknown samples. Samples with a CAA concentration ≥2 pg/ml were considered as positive (Corstjens et al., 2020). For visualization purposes, samples of which the CAA concentration was undetectable or below the cut-off of 2 pg/ml were assigned a fixed value equal to half the cut-off (1 pg/ml).

Data were analyzed using descriptive statistics. For qualitative outcomes, agreement between sample conditions was assessed using Cohen’s kappa coefficient, and differences in paired proportions were evaluated using the exact McNemar’s test. All paired samples were included in this analysis. For quantitative CAA concentrations, differences between paired measurements were assessed using the Wilcoxon signed-rank test, including all paired samples. Associations between paired measurements were assessed using Spearman’s rank correlation coefficient, and agreement and potential bias using Bland-Altman analysis of log-transformed concentrations. These analyses were restricted to samples with CAA concentrations ≥2 pg/ml under both conditions being compared. Mean and median CAA concentrations were likewise calculated only for samples with CAA concentrations ≥2 pg/ml under both conditions compared. Samples with CAA concentrations < 2pg/ml were considered negative for qualitative analyses. All tests were two-tailed, and p-values <0.05 were considered statistically significant. All analyses were performed using SPSS (version 29) and figures were generated using Graphpad Prism (version 10.6.1).

3. Results

A total of 272 urine samples were tested both fresh and after freezing using the UCP-LF CAA test (Tables 1, 2). The proportional Venn-diagram showed substantial overlap in CAA-positive samples between the two conditions (Figure 2A). Among fresh CAA-positive samples, 9 low-positive samples with CAA concentrations close to the positivity cut-off (2–5 pg/ml) tested negative after freezing, while no fresh CAA-negative samples tested positive after freezing (Figure 3; Supplementary Table 1). The difference in discordant pairs was statistically significant (McNemar’s test, p=0.004; Table 2). CAA concentrations tended to be lower after freezing, although this did not reach statistical significance (Wilcoxon signed-rank test, p=0.051; Table 2). A strong correlation was observed between quantitative CAA concentrations in fresh and frozen CAA-positive samples (N = 35, Spearman’s ρ = 0.93, p < 0.0001; Table 2; Figure 3). There was no statistically significant systematic bias in CAA concentrations between fresh and frozen samples. Fresh samples tended to have higher CAA concentrations compared to frozen samples (mean ratio 1.18, 95% limits of agreement 0.41-3.44, Table 2).

For a sub-set of urine samples (N = 153), an additional aliquot was available for non-frozen storage prior to testing (Tables 1, 2). The proportional Venn-diagram showed substantial overlap in CAA-positive samples between conditions (Figure 2B). Non-frozen stored samples showed the highest number of CAA positives (N = 24), of which 18 and 15 were also positive in the corresponding fresh and frozen samples, respectively. Compared with fresh samples, 2 samples changed from positive to negative after non-frozen storage, while 6 changed from negative to positive; this difference was not statistically significant (McNemar’s test, p=0.29; Table 2; Supplementary Table 2). CAA concentrations were comparable between both conditions (Wilcoxon signed-rank test, p=0.751; Table 2). In contrast, the difference in discordant pairs between non-frozen stored and frozen samples was statistically significant with 1 sample changing from positive to negative after non-frozen storage and 9 changed from negative to positive (McNemar’s test, p=0.02; Table 2; Supplementary Table 2). CAA concentrations did not differ significantly between both conditions (Wilcoxon signed-rank test, p=0.397; Table 2). Strong correlations were observed between quantitative CAA concentrations across all storage conditions (Table 2; Figure 4). There was no statistically significant systematic bias in CAA concentrations between fresh, frozen and non-frozen stored samples. Both fresh and frozen samples tended to have lower CAA concentrations compared to non-frozen stored samples (mean ratio 0.91, 95% limits of agreement 0.30-2.77 and mean ratio 0.86, 95% limits of agreement 0.33-2.22, respectively, Table 2).

4. Discussion

In this study, we evaluated the impact of freezing and non-frozen storage on the detection of circulating anodic antigen (CAA) in urine samples using the UCP-LF CAA test in a near-elimination Schistosoma haematobium setting on Pemba, Tanzania. Overall agreement in CAA positivity between storage conditions was high, and quantitative CAA concentrations showed good agreement. Freezing was associated with a small but statistically significant reduction in CAA positivity, while CAA concentrations showed a non-significant trend towards lower values after freezing. This reduction was observed primarily among samples with CAA concentrations close to the assay cut-off of 2 pg/ml, suggesting that analytical variability around the detection threshold may have contributed to the observed differences. Overall, our findings suggest that while CAA is generally stable and suitable for retrospective or centralized testing, freezing may lead to a limited loss of detectable antigen and should be considered when interpreting results in low-intensity settings.

Previous studies have reported stable CAA levels in urine under various storage conditions, including freezing (Corstjens et al., 2014; Corstjens et al., 2015; Corstjens et al., 2020), consistent with our current findings and previous unpublished observations from LUMC. Similarly, we did not observe a significant different in CAA positivity or concentration between fresh and non-frozen stored samples. However, this comparison cannot isolate the effect of storage from potential effects related to transport, timing of analysis, and laboratory conditions, as non-frozen samples were transported to the Netherlands and analyzed at LUMC, whereas fresh and frozen samples were analyzed on Pemba. Nevertheless, the comparable results observed across fresh and non-frozen stored samples indicate that CAA detection was maintained across this field-to-laboratory workflow. This is relevant to settings where immediate testing or freezing is not feasible and samples need to be stored and transported for centralized testing. In our study, non-frozen samples were stored at 4 °C before transport under cooled conditions using ice packs and were tested approximately 5 weeks after collection. The findings therefore demonstrate the feasibility of this specific storage and transport workflow, rather than establishing that non-frozen storage alone has no effect on CAA stability. Standardized storage and transport procedures remain important to preserve sample integrity, particularly during prolonged non-frozen storage, when bacterial or fungal growth could potentially affect CAA detection.

The non-frozen storage condition was introduced approximately half-way through the study and was assessed in a pragmatic subset for which sufficient urine was available. Although selection was not based on participant characteristics or diagnostic outcomes, selection based on available urine volume could potentially have introduced bias. In addition, this study was designed to evaluate different storage conditions rather than storage duration. Fresh samples were tested within 4 hours after collection, frozen samples were stored at -20 °C for 5–7 days before testing, and non-frozen stored samples were tested approximately 5 weeks after collection. These intervals were determined by practical and logistical circumstances rather than prospectively assigned storage periods. Therefore, the effects of storage condition and storage duration cannot be separated, and no conclusions can be drawn regarding the effect of storage duration itself. Further studies are needed to assess longer-term storage at non-frozen temperatures, prolonged frozen storage, and repeated freeze-thaw cycles.

In conclusion, the storage conditions evaluated in this study had a limited overall effect on CAA detection and quantification. Freezing for 5–7 days was associated with a small reduction in positivity, primarily among samples with CAA concentrations close to the assay cut-off, while non-frozen stored samples showed generally comparable results to freshly tested samples. These findings suggest that urine storage strategies may be adapted to facilitate delayed centralized CAA testing, while further evaluation is needed for longer storage periods and repeated freeze-thaw cycles.

Statements

Conflict of interest

The author(s) declared that this work was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

The author LL declared that she was an editorial board member of Frontiers at the time of submission. This had no impact on the peer review process and the final decision.

Funding

The author(s) declared that financial support was received for this work and/or its publication. Funding for the main study has been obtained from the Swiss National Science Foundation (SNSF; Bern, Switzerland) via a PRIMA grant (PR00P3_179753) to SK and by the Leading House Africa via a Consolidation Grant to SK. A grant of the Prof. Dr. P.C. Flu Foundation (8244-30453) in the Netherlands supported part of the work dedicated to the UCP-LF CAA test. NCN was supported by a personal stipend from the Swiss Government Excellence Scholarships (ESKAS) programme and the Swiss Tropical and Public Health Institute (Swiss TPH).

Data availability

The datasets presented in this study can be found in online repositories. The names of the repository/repositories and accession number(s) can be found in the article/Supplementary Material.

Ethics approval

The study protocol was approved by the Ethics Committee of Northern and Central Switzerland (AO_2024-00105) and the Zanzibar Health Research Institute (ZAHREC/01/PR/JAN/2025/01). The studies were conducted in accordance with the local legislation and institutional requirements. Written informed consent for participation in this study was provided by the participants’ legal guardians/next of kin. Written informed consent was obtained from the minor(s)’ legal guardian/next of kin for the publication ofany potentially identifiable images or data included in this article.

Author contributions

PH: Software, Writing – original draft, Data curation, Methodology, Conceptualization, Visualization, Investigation, Validation, Funding acquisition, Resources, Writing – review & editing, Supervision, Formal analysis, Project administration. GD: Writing – review & editing. MB-F: Writing – review & editing, Software, Investigation. DJ: Writing – review & editing. SA: Resources, Writing – review & editing. MA: Writing – review & editing, Resources. NN: Resources, Writing – review & editing. SK: Resources, Writing – review & editing. PC: Writing – review & editing, Investigation. LL: Resources, Methodology, Investigation, Funding acquisition, Supervision, Conceptualization, Writing – review & editing.

References

  1. Abaasa A., Egesa M., Driciru E., Koopman J. P. R., Kiyemba R., Sanya R. E.. (2023). Establishing a single-sex controlled human Schistosoma mansoni infection model for Uganda: protocol for safety and dose-finding trial. Immunother. Adv. 3, ltad010. doi: doi:10.1093/immadv/ltad010
  2. Assaré R. K., Tra-Bi M. I., Coulibaly J. T., Corstjens P., Ouattara M., Hürlimann E.. (2021). Accuracy of two circulating antigen tests for the diagnosis and surveillance of Schistosoma mansoni infection in low-endemicity settings of Côte d'Ivoire. Am. J. Trop. Med. Hyg. 105, 677 – 683. doi: doi:10.4269/ajtmh.21-0031
  3. Buonfrate D., Ferrari T. C. A., Adegnika A. A., Russell Stothard J., Gobbi F. G. (2025). Human schistosomiasis. Lancet 405, 658 – 670. doi: doi:10.1016/s0140-6736(24)02814-9
  4. Bustinduy A. L., Edielu A., Ayebazibwe G. K., Nakyesige R., Anguajibi V., Mpooya S.. (2025). Safety and efficacy of praziquantel 40 mg/kg versus 80 mg/kg in preschool-aged children with intestinal schistosomiasis in Uganda: a 2 × 2 factorial, double-blind, placebo-controlled, phase 2 randomised trial. Lancet Glob. Health 13, e1091 – ee100. doi: doi:10.1016/s2214-109x(25)00095-6
  5. Bustinduy A. L., Waterhouse D., de Sousa-Figueiredo J. C., Roberts S. A., Atuhaire A., van Dam G. J.. (2016). Population pharmacokinetics and pharmacodynamics of praziquantel in Ugandan children with intestinal schistosomiasis: higher dosages are required for maximal efficacy. MBio 7, e00227-16. doi: doi:10.1128/mbio.00227-16
  6. Camprubí-Ferrer D., Romero L., Van Esbroeck M., Wammes L. J., Almuedo-Riera A., Rodriguez-Valero N.. (2021). Improving the diagnosis and management of acute schistosomiasis with antibody, antigen and molecular techniques: lessons from a cluster of six travellers. J. Travel Med. 28, taab101. doi: doi:10.1093/jtm/taab101
  7. Clements M. N., Corstjens P. L. A. M., Binder S., Campbell C. H. Jr., de Dood C. J., Fenwick A.. (2018). Latent class analysis to evaluate performance of point-of-care CCA for low-intensity Schistosoma mansoni infections in Burundi. Parasit Vectors. 11, 111. doi: doi:10.1186/s13071-018-2700-4
  8. Corstjens P., de Dood C. J., Knopp S., Clements M. N., Ortu G., Umulisa I.. (2020). Circulating anodic antigen (CAA): a highly sensitive diagnostic biomarker to detect active Schistosoma infections-improvement and use during SCORE. Am. J. Trop. Med. Hyg. 103, 50 – 57. doi: doi:10.4269/ajtmh.19-0819
  9. Corstjens P., Hoekstra P. T., de Dood C. J., van Dam G. J. (2017). Utilizing the ultrasensitive Schistosoma up-converting phosphor lateral flow circulating anodic antigen (UCP-LF CAA) assay for sample pooling-strategies. Infect. Dis. Poverty. 6, 155. doi: doi:10.1186/s40249-017-0368-1
  10. Corstjens P. L., De Dood C. J., Kornelis D., Fat E. M., Wilson R. A., Kariuki T. M.. (2014). Tools for diagnosis, monitoring and screening of Schistosoma infections utilizing lateral-flow based assays and upconverting phosphor labels. Parasitology 141, 1841 – 1855. doi: doi:10.1017/s0031182014000626
  11. Corstjens P. L., Nyakundi R. K., de Dood C. J., Kariuki T. M., Ochola E. A., Karanja D. M.. (2015). Improved sensitivity of the urine CAA lateral-flow assay for diagnosing active Schistosoma infections by using larger sample volumes. Parasit Vectors. 8, 241. doi: doi:10.1186/s13071-015-0857-7
  12. Deelder A. M., Miller R. L., de Jonge N., Krijger F. W. (1990). Detection of schistosome antigen in mummies. Lancet 335, 724 – 725. doi: doi:10.1016/0140-6736(90)90838-v
  13. de Freitas Galvão R. L., Hoekstra P. T., Corstjens P., Pinheiro M. C. C., da Silva A. M., Barbosa L.. (2025). Evaluating the efficacy of different praziquantel treatment regimens using egg and circulating anodic antigen (CAA) detection methods in a Schistosoma mansoni endemic area in northeastern Brazil. Int. J. Parasitol. Drugs Drug Resist. 29, 100628. doi: doi:10.1016/j.ijpddr.2025.100628
  14. Downs J. A., van Dam G. J., Changalucha J. M., Corstjens P. L., Peck R. N., de Dood C. J.. (2012). Association of schistosomiasis and HIV infection in Tanzania. Am. J. Trop. Med. Hyg. 87, 868 – 873. doi: doi:10.4269/ajtmh.2012.12-0395
  15. Gerstenberg J., Honkpehedji Y. J., Dejon-Agobe J. C., Mahmoudou S., Recker M., Mba R. B.. (2024). Safety and efficacy of praziquantel in pregnant women infected with Schistosoma haematobium in Lambaréné, Gabon - clinical results from the randomized, single-blinded, controlled freeBILy-Gabon trial. Int. J. Infect. Dis. 149, 107253. doi: doi:10.1016/j.ijid.2024.107253
  16. Hoekstra P. T., Casacuberta-Partal M., van Lieshout L., Corstjens P., Tsonaka R., Assaré R. K.. (2022 a). Limited efficacy of repeated praziquantel treatment in Schistosoma mansoni infections as revealed by highly accurate diagnostics, PCR and UCP-LF CAA (RePST trial). PloS Negl.Trop. Dis. 16, e0011008. doi: doi:10.1371/journal.pntd.0011008
  17. Hoekstra P. T., Chernet A., de Dood C. J., Brienen E. A. T., Corstjens P., Labhardt N. D.. (2022 b). Sensitive diagnosis and post-treatment follow-up of Schistosoma mansoni infections in asymptomatic Eritrean refugees by circulating anodic antigen detection and polymerase chain reaction. Am. J. Trop. Med. Hyg. 106, 1240 – 1246. doi: doi:10.4269/ajtmh.21-0803
  18. Hoekstra P. T., Madinga J., Lutumba P., van Grootveld R., Brienen E. A. T., Corstjens P.. (2022 c). Diagnosis of schistosomiasis without a microscope: evaluating circulating antigen (CCA, CAA) and DNA detection methods on banked samples of a community-based survey from DR Congo. Trop. Med. Infect. Dis. 7, 315. doi: doi:10.3390/tropicalmed7100315
  19. Hoekstra P. T., Schwarz N. G., Adegnika A. A., Andrianarivelo M. R., Corstjens P., Rakotoarivelo R. A.. (2020). Fast and reliable easy-to-use diagnostics for eliminating bilharzia in young children and mothers: an introduction to the freeBILy project. Acta Trop. 211, 105631. doi: doi:10.1016/j.actatropica.2020.105631
  20. Hoekstra P. T., van Dam G. J., van Lieshout L. (2021 a). Context-specific procedures for the diagnosis of human schistosomiasis – a mini review. Front.Trop. Dis. 2, 722438. doi: doi:10.3389/fitd.2021.722438
  21. Hoekstra P. T., van Esbroeck M., de Dood C. J., Corstjens P. L., Cnops L., van Zeijl-van der Ham C. J.. (2021 b). Early diagnosis and follow-up of acute schistosomiasis in a cluster of infected Belgian travellers by detection of antibodies and circulating anodic antigen (CAA): a diagnostic evaluation study. Travel Med. Infect. Dis. 41, 102053. doi: doi:10.1016/j.tmaid.2021.102053
  22. Knopp S., Corstjens P. L., Koukounari A., Cercamondi C. I., Ame S. M., Ali S. M.. (2015). Sensitivity and specificity of a urine circulating anodic antigen test for the diagnosis of Schistosoma haematobium in low endemic settings. PloS Negl.Trop. Dis. 9, e0003752. doi: doi:10.1371/journal.pntd.0003752
  23. Koopman J. P. R., Houlder E. L., Janse J. J., Casacuberta-Partal M., Lamers O. A. C., Sijtsma J. C.. (2023). Safety and infectivity of female cercariae in Schistosoma -naïve, healthy participants: a controlled human Schistosoma mansoni infection study. EBioMedicine 97, 104832. doi: doi:10.1016/j.ebiom.2023.104832
  24. Langenberg M. C. C., Hoogerwerf M. A., Koopman J. P. R., Janse J. J., Kos-van Oosterhoud J., Feijt C.. (2020). A controlled human Schistosoma mansoni infection model to advance novel drugs, vaccines and diagnostics. Nat. Med. 26, 326 – 332. doi: doi:10.1016/s1473-3099(20)30020-7
  25. Lorenz E., Razafindrakoto R., Rausche P., Rasolojaona Z. T., Razafindralava N. M., Zerbo A.. (2025). Detecting Schistosoma infections in endemic countries: a diagnostic accuracy study in rural Madagascar. Infect. Dis. Poverty. 14, 20. doi: doi:10.1186/s40249-025-01292-x
  26. Miller R. L., Armelagos G. J., Ikram S., De Jonge N., Krijger F. W., Deelder A. M. (1992). Palaeoepidemiology of Schistosoma infection in mummies. Bmj 304, 555 – 556. doi: doi:10.1136/bmj.304.6826.555
  27. Ndum N. C., Ali S. M., Ali M. N., Bergelin J., Hattendorf J., Hoekstra P. T.. (2026). Evaluation of six different tests for Schistosoma haematobium diagnosis in a near-elimination setting: a prospective observational diagnostic accuracy study. PloS Negl. Trop. Dis. doi: doi:10.1371/journal.pntd.0014066
  28. Sousa M. S., van Dam G. J., Pinheiro M. C. C., de Dood C. J., Peralta J. M., Peralta R. H. S.. (2019). Performance of an ultra-sensitive assay targeting the circulating anodic antigen (CAA) for detection of Schistosoma mansoni infection in a low endemic area in Brazil. Front. Immunol. 10, 682. doi: doi:10.3389/fimmu.2019.00682
  29. Tamarozzi F., Ursini T., Hoekstra P. T., Silva R., Costa C., Gobbi F.. (2021). Evaluation of microscopy, serology, circulating anodic antigen (CAA), and eosinophil counts for the follow-up of migrants with chronic schistosomiasis: a prospective cohort study. Parasit Vectors. 14, 149. doi: doi:10.1186/s13071-021-04655-z
  30. van Dam G. J., de Dood C. J., Lewis M., Deelder A. M., van Lieshout L., Tanke H. J.. (2013). A robust dry reagent lateral flow assay for diagnosis of active schistosomiasis by detection of Schistosoma circulating anodic antigen. Exp. Parasitol. 135, 274 – 282. doi: doi:10.1016/j.exppara.2013.06.017
  31. van Dam G. J., Odermatt P., Acosta L., Bergquist R., de Dood C. J., Kornelis D.. (2015 a). Evaluation of banked urine samples for the detection of circulating anodic and cathodic antigens in Schistosoma mekongi and S. japonicum infections: a proof-of-concept study. Acta Trop. 141, 198 – 203. doi: doi:10.1016/j.actatropica.2014.09.003
  32. van Dam G. J., Xu J., Bergquist R., de Dood C. J., Utzinger J., Qin Z. Q.. (2015 b). An ultra-sensitive assay targeting the circulating anodic antigen for the diagnosis of Schistosoma japonicum in a low-endemic area, People's Republic of China. Acta Trop. 141, 190 – 197. doi: doi:10.1016/j.actatropica.2014.08.004
  33. Vonghachack Y., Sayasone S., Khieu V., Bergquist R., van Dam G. J., Hoekstra P. T.. (2017). Comparison of novel and standard diagnostic tools for the detection of Schistosoma mekongi infection in Lao People's Democratic Republic and Cambodia. Infect. Dis. Poverty. 6, 127. doi: doi:10.1186/s40249-017-0335-x

Citation

Hoekstra, P. T., et al. (2026). Effect of urine storage conditions on circulating anodic antigen detection using the UCP-LF CAA test. Frontiers in Parasitology, Volume 5. https://doi.org/
Received
Accepted
Published
Volume
5 - 2026

Copyright

Copyright © 2026 Hoekstra, van Dam, Blokland-Flink, de Jong, Ali, Ali, Ndum, Knopp, Corstjens and van Lieshout.

License: https://creativecommons.org/licenses/by/4.0/

*Correspondence: Pytsje T. Hoekstra

Article metrics

Views
0
Downloads
0
Citations
0
Shares
0